1、BLU-RAY DISC PLAYERSERVICE MANUALMODEL: BD390CAUTIONBEFORE SERVICING THE UNIT, READ THE “SAFETY PRECAUTIONS”IN THIS MANUAL.MODEL: BD390SERVICE MANUALP/NO : AFN73271528 OCTOBER, 2009Website http:/Internal Use OnlyRadioFans.CN 收音机爱 好者资料库CONTENTSSECTION 1 .SUMMARYSECTION 2 .CABINET & MAIN CHASSISSECTIO
2、N 3 .ELECTRICALSECTION 4 .HL-05P LOADER PARTSECTION 5 .REPLACEMENT PARTS LIST 1-1RadioFans.CN 收音机爱 好者资料库SECTION 1SUMMARYCONTENTSPRODUCT SAFETY SERVICING GUIDELINES FORBLU-RAY DISC PLAYER PRODUCTS . 1-3SERVICING PRECAUTIONS . 1-4 GENERAL SERVICING PRECAUTIONS INSULATION CHECKING PRODEDURE ELECTROSTAT
3、ICALLY SENSITIVE (ES) DEVICESSOFTWARE UPGRADE . 1-5SPECIFICATIONS . 1-6 1-2PRODUCT SAFETY SERVICING GUIDELINESFOR BLU-RAY DISC PLAYER PRODUCTSIMPORTANT SAFETY NOTICEThis manual was prepared for use only by properly trained audio-video service technicians.When servicing this product, under no circums
4、tances should the original design be modified or altered without permission from LG Corporation. All components should be replaced only with types identical to those in the original circuit and their physical location, wiring and lead dress must conform to original layout upon completion of repairs.
5、Special components are also used to prevent x-radiation, shock and fire hazard.These components are indicated by the letter “x” included in their component desig-nators and are required to maintain safe performance. No deviations are allowed without prior approval by LG Corporation.Circuit diagrams
6、may occasionally differ from the actual circuit used. This way, implementation of the latest safety and performance improvement changes into the set is not delayed until the new service literature is printed.CAUTION : Do not attempt to modify this product in any way. Never perform cus-tomized instal
7、lations without manufacturers approval. Unauthorized modifications will not only void the warranty, but may lead to property damage or user injury.Service work should be performed only after you are thoroughly familiar with these safety checks and servicing guidelines.GRAPHIC SYMBOLSThe exclamation
8、point within an equilateral triangle is intended to alert the service personnel to important safety information in the service literature.The lightning flash with arrowhead symbol within an equilateral trian-gle is intended to alert the service personnel to the presence of non-insulated “dangerous v
9、oltage” that may be of sufficient magnitude to constitute a risk of electric shock.The pictorial representation of a fuse and its rating within an equilat-eral triangle is intended to convey to the service personnel the follow-ing fuse replacement caution notice:CAUTION : FOR CONTINUED PROTECTION AG
10、AINST RISK OF FIRE, REPLACE ALL FUSES WITH THE SAME TYPE AND RATING AS MARKED NEAR EACH FUSE.SERVICE INFORMATIONWhile servicing, use an isolation transformer for protection from AC line shock. After the original service problem has been corrected, make a check of the following:FIRE AND SHOCK HAZARD1
11、. Be sure that all components are positioned to avoid a possibility of adjacent component shorts. This is especially important on items trans-ported to and from the repair shop.2. Verify that all protective devices such as insulators, barriers, covers, shields, strain reliefs, power supply cords, an
12、d other hardware have been reinstalled per the original design. Be sure that the safety purpose of the polarized line plug has not been defeated.3. Soldering must be inspected to discover possible cold solder joints, solder splashes, or sharp solder points. Be certain to remove all loose foreign par
13、ti-cles.4. Check for physical evidence of damage or deterioration to parts and compo-nents, for frayed leads or damaged insulation (including the AC cord), and replace if necessary.5. No lead or component should touch a high current device or a resistor rated at 1 watt or more. Lead tension around p
14、rotruding metal surfaces must be avoided.6. After reassembly of the set, always perform an AC leakage test on all exposed metallic parts of the cabinet (the channel selector knobs, antenna terminals, handle and screws) to be sure that set is safe to operate without danger of elec-trical shock. DO NO
15、T USE A LINE ISOLATION TRANSFORMER DURING THIS TEST. Use an AC voltmeter having 5000 ohms per volt or more sensitivity in the following manner: Connect a 1500 ohm, 10 watt resistor, paralleled by a .15 mfd 150V AC type capacitor between a known good earth ground water pipe, conduit, etc.) and the ex
16、posed metallic parts, one at a time. Measure the AC voltage across the combination of 1500 ohm resistor and .15 mfd capacitor. Reverse the AC plug by using a non-polarized adaptor and repeat AC voltage measurements for each exposed metallic part. Voltage measured must not exceed 0.75 volts RMS. This
17、 corresponds to 0.5 milliamp AC. Any value exceed-ing this limit constitutes a potential shock hazard and must be corrected immedi-ately.TIPS ON PROPER INSTALLATION1. Never install any receiver in a closed-in recess, cubbyhole, or closely fitting shelf space over, or close to, a heat duct, or in the
18、 path of heated air flow. 2. Avoid conditions of high humidity such as: outdoor patio installations where dew is a factor, near steam radiators where steam leakage is a factor, etc. 3. Avoid placement where draperies may obstruct venting. The customer should also avoid the use of decorative scarves
19、or other coverings that might obstruct ventilation.4. Wall- and shelf-mounted installations using a commercial mounting kit must fol-low the factory-approved mounting instructions. A product mounted to a shelf or platform must retain its original feet (or the equivalent thickness in spacers) to prov
20、ide adequate air flow across the bottom. Bolts or screws used for fasteners must not touch any parts or wiring. Perform leakage tests on customized instal-lations.5. Caution customers against mounting a product on a sloping shelf or in a tilted position, unless the receiver is properly secured.6. A
21、product on a roll-about cart should be stable in its mounting to the cart. Caution the customer on the hazards of trying to roll a cart with small casters across thresholds or deep pile carpets.7. Caution customers against using extension cords. Explain that a forest of exten-sions, sprouting from a
22、 single outlet, can lead to disastrous consequences to home and family. 1-3SERVICING PRECAUTIONSCAUTION: Before servicing the BLU-RAY DISC PLAYER covered by this service data and its supplements and addends, read and follow the SAFETY PRECAUTIONS. NOTE: if unforeseen circumstances create conflict be
23、tween the following servicing precautions and any of the safety pre-cautions in this publications, always follow the safety precau-tions.Remember Safety First :General Servicing Precautions1. Always unplug the BLU-RAY DISC PLAYER AC power cord from the AC power source before: (1) Removing or reinsta
24、lling any component, circuit board, module, or any other assembly. (2) Disconnecting or reconnecting any internal electrical plug or other electrical connection. (3) Connecting a test substitute in parallel with an electro-lytic capacitor. Caution : A wrong part substitution or incorrect polarity in
25、stallation of electrolytic capacitors may result in an explosion hazard.2. Do not spray chemicals on or near this BLU-RAY DISC PLAYER or any of its assemblies.3. Unless specified otherwise in this service data, clean elec-trical contacts by applying an appropriate contact cleaning solution to the co
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- LG-BD390-br-sm 维修电路原理图 LG BD390 br sm 维修 电路 原理图