LEM-P300-pwr-sm 维修电路原理图.pdf
《LEM-P300-pwr-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《LEM-P300-pwr-sm 维修电路原理图.pdf(7页珍藏版)》请在收音机爱好者资料库上搜索。
1、1 1 1 1 1 J J J J JCODE : 277318Index & WarningsSoldering point.Male connector.Female connector.M/F faston connector.Test point.Supply voltage.Logic supply ground.Analog supply ground.Signal ground.Chassis ground.Flag joined with one or more flags with the same signal name inscribed.GENERALMUSIC S.p
2、.A. Sales Division: 47842 S.Giovanni in Marignano (RN) ITALY - Via delle Rose, 12 - tel. 0541/959511 - tlx 550555 GMUSIC I - fax 0541/957404Technical Specifications, Test Procedures & Adjustments2NoticeService must be carried out by qualified personnel only. Any tampering carried out by unqualified
3、personnel during the guarantee period will forfeit the right to guarantee.For a correct operation of the instrument, after having switched off, be careful to wait at least 3 seconds before switching on again.To improve the devices specifications, the schematic diagrams may be subject to change witho
4、ut prior notice.Schematic NotesAll components marked by this symbol have special safety characteristics, when replacing any of these components use only manufacturers specified parts.The () micro symbol of capacitance value is substituted by U. The () omega symbol of resistance value is substituted
5、by E. The electrolytic capacitors are 25Vdc rated voltage unless otherwise specified. All resistors are 1/4W unless otherwise specified.ATTENTIONObserve precautions when handlingelectrostatic sensitive devicesSERVICE MANUALSchematic DiagramsWiring Connections4Inputs & Protections, Power Supply and D
6、isplay Boards67Part List, LayoutPower Amplifier Board5RadioFans.CN 收音机爱 好者资料库J J J J J 2 2 2 2 2TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions:(WxHxD)483x44x310mm (1U)Weight:8KgPower Requirements:(230Vac10% 50Hz)300V
7、AOutput Power:(8 stereo/parallel)2x 150WattsMax. Undistorted Out: (8 stereo/parallel)98VppInput Sensitivity:(constant sensitivity)0.775Vrms (0dB)(constant gain)1.75Vrms (+7dB)Input Impedance:(balanced)30K(unbalanced)15KVoltage Gain:(constant sensitivity)330.5dB(constant gain)260.5dBSlew Rate:25V/SDa
8、mping Factor:(8 stereo/parallel)400Frequency Response(-0.2dB)20Hz20KHzat Full Power:(-3dB)10Hz60KHzIMD:(SMPTE 60Hz/7KHz 4:1)0.1%THD:(THD+N)95dBCrosstalk:(1KHz)70dBTEST PROCEDURES & ADJUSTMENTSTEST PROCEDURES & ADJUSTMENTSTEST PROCEDURES & ADJUSTMENTSTEST PROCEDURES & ADJUSTMENTSTEST PROCEDURES & ADJ
9、USTMENTSPrecautionPrecautionPrecautionPrecautionPrecaution To prevent short circuit during any test, the oscilloscope must bethe oscilloscope must bethe oscilloscope must bethe oscilloscope must bethe oscilloscope must beEARTH insulatedEARTH insulatedEARTH insulatedEARTH insulatedEARTH insulated, th
10、is occurs because some test require to connect itsprobe to the amplifier output, non-compliance may cause damages tooscilloscope inputs circuitry. Before removing or installing any modules and connectors, disconnectdisconnectdisconnectdisconnectdisconnectthe amplifier from AC MAINSthe amplifier from
11、 AC MAINSthe amplifier from AC MAINSthe amplifier from AC MAINSthe amplifier from AC MAINS and measure the DC supply voltagesacross each of the power suppliy capacitors. If your measurement on anyof the caps is greater than 10Vdc, connect a 100 10W resistor acrossthe applicable caps to discharge the
12、m for your safety. Remember toremove the discharge resistor immediately after discharging caps. Do notDo notDo notDo notDo notpower up the amplifier with the discharge resistor connectedpower up the amplifier with the discharge resistor connectedpower up the amplifier with the discharge resistor con
13、nectedpower up the amplifier with the discharge resistor connectedpower up the amplifier with the discharge resistor connected. Read these notes entirely before proceeding to any operation. Thesenotes are not comprehensive of all damages that possibly occur, butincludes some specifically advices, ch
14、ecks and adjustments relative tothis amplifier.RemarksRemarksRemarksRemarksRemarks The power supply utilizes a dual bipolar DC rail configuration with low andhigh voltages; one positive and one negative low rail (+/-Vcc1) and onepositive and one negative high rail (+/-Vcc2).Visual CheckVisual CheckV
15、isual CheckVisual CheckVisual Check Use compressed air to clear dust in the amplifier chassis. Before proceed to supply the amplifier check visually the internal assem-bly, if appears an evident damage find the most possible reasons thatcause it. Check the wiring cables for possible interruptions or
16、 shorts. If the damage has burnt a printed circuit board dont try to repair it,replace with a new one.Test InstrumentsTest InstrumentsTest InstrumentsTest InstrumentsTest Instruments Audio Generator Dual Trace Oscilloscope Digital Multimeter 4 500W, 8 300W, 100 10W resistors Variac (0250Vac)SetupSet
17、upSetupSetupSetup Connect the Variac between the mains and the amplifier and set it at zerovoltage. Set the amplifier in STEREO MODE and turn full clockwise the LEVELpotentiometers. Connect the audio generator to the channel inputs and set it to 1KHz775mVRMS (0dB) sinusoidal signal. The procedures t
18、hat follow must be executed subsequently in the orderspecified.Supply CheckSupply CheckSupply CheckSupply CheckSupply Check Remove the transformer secondary fuses (located on SUPPLY & PRO-TECTIONS board), set the Variac to the nominal mains voltage, checkwith the Multimeter the AC supply voltages:F1
19、-F2=521.5VacF3-F4=883Vac. Re-set the Variac at zero voltage, turn off the amplifier and put the fusesback on its holders. Connect the oscilloscope probes CH1/2 to the channel outputs, beforeRL1, set both to 20V/div. 200S/div. Set up the Variac slowly monitoring the Outputs with the oscilloscopeCH1/2
20、 connected, it should display the sinusoidal input signal amplifiedwith no distortions, if a distortion occur check the POWER AMPLIFIERboards as suggested in the ADVICES section. If the protection trips, turn off the amplifier, wait some minutes anddisconnect the supplies from the outputs modules (C
21、N1, CN4 on POWERAMPLIFIER boards), continue to check the supplies. CAUTION: Before re-connecting the output modules to the supplies,CAUTION: Before re-connecting the output modules to the supplies,CAUTION: Before re-connecting the output modules to the supplies,CAUTION: Before re-connecting the outp
22、ut modules to the supplies,CAUTION: Before re-connecting the output modules to the supplies,you must have the capacitors discharged for your safety: connect ayou must have the capacitors discharged for your safety: connect ayou must have the capacitors discharged for your safety: connect ayou must h
23、ave the capacitors discharged for your safety: connect ayou must have the capacitors discharged for your safety: connect a100100100100100 10W resistor across the caps and remove the resistor just after 10W resistor across the caps and remove the resistor just after 10W resistor across the caps and r
24、emove the resistor just after 10W resistor across the caps and remove the resistor just after 10W resistor across the caps and remove the resistor just afterthey are discharged.they are discharged.they are discharged.they are discharged.they are discharged. Finally verify the DC supplies on POWER SU
25、PPLIES board:CN1 pin 1-2 (+Vcc2)=+612VdcCN1 pin 3-4 (+Vcc1)=+361.5VdcCN2 pin 1-2 (-Vcc1)=-361.5VdcCN2 pin 3-4 (-Vcc2)=-612VdcCN3 pin 3-4-5=+151VdcCN3 pin 7-9-10=-151Vdc If one or more voltages dont correspond, check the rectifiers, capacitorsand transformers disconnecting them from circuitry, refer