Infinity-TSS1200-sub-sm 维修电路原理图.pdf
《Infinity-TSS1200-sub-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Infinity-TSS1200-sub-sm 维修电路原理图.pdf(19页珍藏版)》请在收音机爱好者资料库上搜索。
1、 TSS-Sub1200 TSS-Sub1200 (TSS-1200 SYSTEM) SERVICE MANUAL Infinity Systems Incorporated 250 Crossways Park Dr. Woodbury, New York 11797 Rev0 12/2006 RadioFans.CN 收音机爱 好者资料库 Note: The TSS-Sub1200 is part of the TSS-1200 system Satellite loudspeakers: (Charcoal) order Infinity part# TSS-SAT1200CHR (Pl
2、atinum) order Infinity part# TSS-SAT1200PLT Center channel: (Charcoal) order Infinity part# TSS1200CHR CEN (Platinum) order Infinity part# TSS1200PLT CEN CONTENTS BASIC SPECIFICATIONS . . . . . . . . . . . . . . . . 1 DETAILED SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 PA
3、CKAGING/ACCESSORIES. . . . . . . . . . . . . . . . . . . . . . . . . . . 4 CONTROLS. . . . . 5 CONNECTIONS . . . . . . . . . . . . . . . 6 OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 EXPLODED VIEW-MECHANICAL PARTS LIST. . .8 TEST SET-UP/PROCEDURE. . . . . . . . .
4、. . . . . . . . . . . . . . . . . . 9 BLOCK DIAGRAM. . . . . . . . . . . 10 PCB DRAWINGS. . . . . . . . . . . . . . . . . . . . . 11 ELECTRICAL PARTS LIST . .13 IC TRANSISTOR PINOUTS . . . . . . . . . . . . . 16 SCHEMATIC DIAGRAMS . . . . .17 TSS-Sub1200 Specifications Frequency Range: 29Hz 150Hz (3
5、dB) Amplifier Output: 250 Watts RMS; 500 Watts peak Low-Frequency Driver: 12 (305mm) Crossover Frequency: 50Hz 150Hz, 24dB/Octave, continuously variable Dimensions (H x W x D): 18-1/2 x 12-3/4 x 18-1/2 (470mm x 324mm x 470mm) Weight: 44 lb (20kg) Infinity continually strives to update and improve ex
6、isting products, as well as create new ones. The specifications and construction details in this and related Infinity publications are therefore subject to change without notice. TSS-Sub1200 subwoofer RadioFans.CN 收音机爱 好者资料库INFINITY TSS-1200 250W Powered Sub/ Plate Amp LINE VOLTAGEYes/NoHi/Lo LineNo
7、m.UnitNotesUS 120vac/60HzYes108-132120VrmsNormal OperationEU 230vac/50-60HzYes207-264230VrmsNormal operation, MOMS requiredParameterSpecificationUnitQA Test LimitsConditionsNotesAmp SectionType (Class AB, D, other)Dn/an/aLoad Impedance (speaker)5.6Ohmsn/aNominalRated Output Power (120VAC150Watts125D
8、omestic version only 120 VAC-60 HzRated Output Power (230VAC150Watts125EU Version only 230 VAC-50 HzAVG RMS Dynamic Power250Watts2255.6 Ohms Average RMS power, 3/20 Cycles 50 Hz, Driven 6dB above its input sensitivity sensitivityAVG RMS Dynamic Power250Watts1894 Ohms ReferenceTHD Rated Power0.5%122K
9、 filterTHD 1 Watt0.1%0.322K filterDC Offset10mV-DC30Amplifier outputDamping factor50DF20Measured at amplifier board Measured at the amplifier board. 120 Watts 50 Hz, THD must be less tan 0.1%Input SensitivityInput Frequency35Hz35Nominal Freq.L or R input16.8mVrms2dBTo 1 Watt, Ap Zo=600 OhmsSingle in
10、put driven, Normal modeL or R input16.8mVrms2dBTo 1 Watt , Ap Zo=600 OhmsSingle input driven, LFE mode switch ONGain L & R1402dB43 dBReference Signal to NoiseSNR-A-Weighted90dBA85relative to rated powerA-Weighting filterSNR-unweighted85dBr85relative to rated power22K filterSNR rel. 1W-unweighted65dB
11、r65relative to 1W Output22K filterResidual Noise Floor1mVrms(max)1.5Volume max, w/ A/P Swept Bandpass Measurement (Line freq.+ harmonics) (BW=20 Khz)Line level inputs must be terminated using 1KOHMInput ImpedanceLine Input (L, R) 10Kohmsn/aNominalFiltersLP filter 4th order 50-150Hz 102nd Order varia
12、ble and 2nd order fixSee AP curves 2nd order variable + 2nd order fix-24 db/OctaveHP Filter 2nd orderFixedLFE Low pass 2nd order200LP T 18 MinutesPower on Delay time3sec.4AC Power AppliedTransients/PopsATO Transient5mV-peakn/a Speaker Output TSS-Sub1200 subwoofer 2ParameterSpecificationUnitQA Test L
13、imitsConditionsNotesTurn-on Transient50mV-peak2V-pk-pk Speaker OutputAC Line cycled from OFF to ONTurn-off Transient50mV-peak2V-pk-pk Speaker OutputAC Line cycled from ON to OFFEfficiencyEfficiency67%65Nominal Line voltage 120 VACStand-by Input Power20Watts22 nom. line voltageMaximum allowable input
14、 power under nominal Input voltage and frequency, HOT or COLD operation.Power Cons. rated power185Watts187 nom. line voltage125 Watts into 5.6 Ohms nominal line voltageProtectionsShort Circuit Protection YESfunctional Direct short at outputAmplifier should resume operation after short circuit condit
15、ion removal Thermal Protection YESfunctional1/8 max unclipped Power at 1.06 times the input voltageTemperature rise in accessible metal parts should not exceed 35K rise for domestic version or 30K rise for European versions (refer to requirements sheet).DC Offset ProtectionYES-DC present at Speaker
16、Out leadsDesign must insure no Offset at the speaker output under any operating condition including abnormal operationLine Fuse RatingUSA-Domestic 2Amps2Type-T or Slo Blo-250 VInternal fuse with UL/SEMKO rated holderEU1.25Amps1.25Type-T or Slo Blo-250 V, Low Breaking capacityInternal fuse with UL/SE
17、MKO rated holder TSS-Sub1200 subwoofer 3 TSS-Sub1200 subwoofer 4SUBWOOFERCONTROLSRear PanelCROSSOVERFREQUENCYLEVELLINE LEVEL INPHASEMinMaxLRFor LFE use L or RLFENORMALPOWER50Hz80Hz0180150HzCAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENONOFFNRTL/CCSA22.2UL1492WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC
18、 SHOCK,DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.AVERTISSEMENT: POUR PRVENIR LES RISQUES DINCENDIE OUDE CHOC LECTRIQUE, VITER DEXPOSER CET APPAREIL A LA PLUIE OU A LHUMIDIT.A Few SuggestionsWe recommend that you do not operate your speakers orsubwoofer with the bass,treble and loudness contro
19、ls set to full boost.This will place undue strain on your electronics andspeakers and could damage them.The volume control setting on your processor/preamp or receiveris not a specific indication of the overall loudness level of thespeakers.The only important consideration is the loudness level atwh
20、ich the system can be played,regardless of where the volumecontrol is set.Always turn down the volume control setting on your processor/preamp or receiver when changing a cassette or CD,or switchinginputs to AM or FM operation.Excessively loud transients (clicks orpopping sounds) can damage the sate
21、llite speakers and possiblythe subwoofer.Important!Whenever changing cables,pulling plugs,etc.,ALWAYS TURN OFFALL EQUIPMENT,including the subwoofer.1Subwoofer-Level Control 2LFE/Normal Switch3Phase Switch4Crossover-Frequency Control 5Line-Level (LFE) Inputs6Power SwitchTSS-1200 (120V) OM 7/18/06 9:0
22、2 AM Page 10 TSS-Sub1200 subwoofer 5SUBWOOFERCONNECTIONSIf your receiver/processor does not contain a Dolby Digital or DTS processor but has asubwoofer output:Set line-level/LFE switch to “Normal.”N NO OT TE E:If your receiver/processor has only one sub out,you may use either the L or R input.If you
23、 have a DolbyDigital or DTSreceiver/processor with a low-frequency-effects (LFE) or subwoofer output:CROSSOVERFREQUENCYLEVELLINE LEVEL INPHASEMinMaxL RFor LFE use L or RLFE NORMALPOWER50Hz80Hz0180150HzCAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENONOFFNRTL/CCSA22.2UL1492WARNING: TO REDUCE THE RISK OF FIRE
24、 OR ELECTRIC SHOCK,DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.AVERTISSEMENT: POUR PRVENIR LES RISQUES DINCENDIE OUDE CHOC LECTRIQUE, VITER DEXPOSER CET APPAREIL A LA PLUIE OU A LHUMIDIT.SUBWOOFER ORLFE OUTPUTSet line-level/LFE switch to “LFE.”CROSSOVERFREQUENCYLEVELLINE LEVEL INPHASEMinMaxL RF
25、or LFE use L or RLFE NORMALPOWER50Hz80Hz0180150HzCAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENONOFFNRTL/CCSA22.2UL1492WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.AVERTISSEMENT: POUR PRVENIR LES RISQUES DINCENDIE OUDE CHOC LECTRIQUE, VITER DEXPOSE