Infinity-BU120revD-sub-sm 维修电路原理图.pdf
《Infinity-BU120revD-sub-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Infinity-BU120revD-sub-sm 维修电路原理图.pdf(34页珍藏版)》请在收音机爱好者资料库上搜索。
1、Infinity Systems Inc.250 Crossways Park DriveWoodbury, N.Y. 117971-800-553-3332A Harman International CompanyRev D 11/2000BU-120/HTS-20Powered SubwooferSERVICE MANUALRadioFans.CN 收音机爱 好者资料库SAFETY INFORMATIONWarningAny person performing service of this unit will be exposed tohazardous voltages and th
2、e risk of electric shock.It isassumed that any person who removes the amplifier from thiscabinet hasbeen properly trained in protecting againstavoidable injury and shock.Therefore, any serviceprocedures are to be performed by qualified service personalONLY!CautionThis unit does not have a power swit
3、ch. Hazardous voltagesare present within the unit whenever it is plugged in.Before the amplifier is plugged in, be sure its rated voltagecorresponds to the voltage of the AC power source to beused. Incorrect voltage could cause damage to the amplifierwhen the AC power cord is plugged in. Do not exce
4、ed ratedvoltage by more than 10%: operation below 90% of ratedvoltage will cause poor performance or may shut the unit off.List of SafetyComponents RequiringExactReplacementsF1Fuse SLO BLO 1.0A 250V 20mm.UL approvedPWRCORDSPT- 2 or better with polarized plug, ULapproved wired with the hot side to fu
5、sed side.Use with factory replacement panel strain reliefonly.T1Transformer. Use only factory replacement.DBR or D1Bridge diode. Use only factory replacement.C1, 24700uF, 50V electrolytic filter caps. Be surereplacement part is at least the same workingvoltage and capacitance rating. Also the leadsp
6、acing is important. Incorrect spacing maycause premature failure due to internal cabinetpressure and vibration.C610uF 50V electrolytic radial* BU120 and HTS- 20 rev. A only.S53AMI or CN1Power output module. Use only factoryreplacementFaceplateFaceplate. Use only factory replacementAir leak coverUse
7、only factory replacementCMC1Use only factory replacementL1Use only factory replacementFuse PCBUse only factory replacementMain PCBUse only factory replacementR29470 .25W METAL OXIDE, non flammableLeakage/Resistance CheckBefore returning the unit to the customer, perform a leakageor resistance test a
8、s follows:Leakage Current. Note there is no power switch on this unit.When the power plug is plugged in, the unit is live. Connectthe unit to its rated power source. Using an ammeter,measure the current between the neutral side of the ACsupply and chassis ground of the unit under test. if leakagecur
9、rent exceeds 0.5mA, the unit is defective. Reverse thepolarity of the AC supply and repeat.Resistance. Measure the resistance from either side of theline cord to chassis ground. If it is less than 500k ohms, theunit is defective.WARNING! DO NOT return the unit to the customer if it failsone of these
10、 tests until the problem is located and corrected.2Amplifier/SubwooferBU-120/HTS-20*See Service Bulletin (INF2000-01) page 15.RadioFans.CN 收音机爱 好者资料库3Amplifier/SubwooferBU-120/HTS-20GENERAL SPECIFICATIONSFrequency Response ( 3dB) . . . . . . . . . . . . . . . . . 30Hz 150HzOutput (RMS). . . . . . .
11、. . . . . . . . . . . . . . . . . . . . . . 150WDriver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 WooferCrossover Frequency . . . . . . . . . . . . . . . . . . . . . . . 50Hz 150Hz (continuously variable)Dimensions (H x W x D) . . . . . . . . . . . . . . . . . . . . . 14
12、(36.8cm) x 14 ? (36.8cm) x14 ? (36.8cm)Add 1 ? (4.5cm) for feet.Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 lbs/19.5 kg,Refinements may be made on occasion to existing products without notice,but will always meet or exceed original specifications unless otherwise sta
13、ted.TABLE OF CONTENTSSAFETY INFORMATION.2GENERAL SPECIFICATIONS.3DETAILED SPECIFICATIONS .4CONTROLS AND THEIR FUNCTION .6BU- 120/HTS- 20 CONNECTIONS.7OPERATION .11BU- 120/HTS- 20 TEST SET UP AND PROCEDURE .12BU- 120/HTS- 20 POWER AMP MODULETESTING FLOW CHART .13SERVICE BULLETIN INF9902 - APRIL 1999
14、.14SERVICE BULLETIN INF2000- 01 - JANUARY 2000.15TECH TIPS .16BU- 120/HTS- 20 PACKING & CABINET ASSEMBLY.17BU- 120/HTS- 20 AMPLIFIER ASSEMBLYEXPLODED VIEW .18BU- 120/HTS- 20 rev. A PCB (revision 3.52)Component Side Trace.20BU- 120/HTS- 20 rev. A PCB (revision 3.52)Solder Side Trace.21BU- 120/HTS- 20
15、 rev. A PCB (revision 3.53)Component Side Trace.22BU- 120/HTS- 20 rev. A PCB (revision 3.53)Solder Side Trace.23BU- 120/HTS- 20 ELECTRICAL PARTS LIST.24BU- 120/HTS- 20 IC DIAGRAMS .25BU- 120/HTS- 20 SCHEMATIC 1 of 2 .26BU- 120/HTS- 20HTS- 20 REV B ELECTRICAL PARTS LISTSCHEMATIC 2 of 2 .27.28HTS- 20
16、REV B SCHEMATIC.33HTS- 20 REV B CIRCUIT BOARDS.31REGARDING SERVICE FOR THE INFINITY HTS- 20 SUBWOOFERThere are two versions, an A and B, with minor internal differences.Data for both versions is included, and differences noted in the following pages.Units can be identified for service as follows:?Am
17、plifier faceplate says Made in Canada on the A version.?Amplifier faceplate says Made in China on the B version.DETAILED SPECIFICATIONSLINE VOLTAGEYes/NoHi/LoLineNom.UnitNotesUS 120vac/60HzYes108-132120VrmsNormal OperationEU 230vac/50-60HzYes207-264230VrmsNormal operation, MOMSrequiredAsia 100vac/50
18、HzNo90-110100VrmsNormal OperationParameterSpecificationUnitQA TestLimitsConditionsNotesAmp SectionType (Class AB, D,other)Dn/an/aClass D Preferred.Sinkrequired for Class ABLoad Impedance(speaker)4Ohmsn/aNominalZ-curve requiredRated Output Power150Watts1501 input drivenTHD0.3%122k filter75w (Power Ba
19、ndwidth30-100Hz)THD 1 Watt0.5%0.822k filterDC Offset10mV-DC20 Speaker OutputsDamping factor100DF50Input SensitivityInput Frequency40HzNominal Freq.1 input drivenLine Input63mVrms2dBTo Rated Power/ Vol Max1 input driven: AP sourceZ = 600 ohmsSpeaker/Hi Level Input4.8Vrms2dBTo Rated Power/ Vol Max1 in
20、put driven: AP sourceZ = 25 ohmsSignal to NoiseSNR-A-Weighted100dBA90Relative to rated outputA-Weighting filterSNR-unweighted75dBr70Relative to rated output22k filterSNR rel. 1W-unweighted 65dBr55relative to 1W Output22k filterResidual Noise Floor3mVrms4Volume max, usingRMS reading on A/P22k filter
21、required due to100kHz switching noisepresent at speaker outputInput ImpedanceLine Input10kohmsn/aNominalSpeaker/Hi Level Input200ohmsn/aNominalFilters0dBr = 1w 50HzLow Pass (fixed orvariable)VariableLow Pass filter (point orrange)50-150Hz2dB-3dB PointSlope18-24dB/Octaven/aSubsonic filter (HPF)34Hz2d
22、B-3dB PointSlope24dB/Octaven/a4Amplifier/SubwooferBU-120/HTS-20Limiter (yes/no)yesMax. OutputPower/THD=10%150w/10%P-max/THDfunctionalMaximum Output PowerMaximum THD as a resultof limiting.FeaturesPhase Switch (yes/no)yesfunctionalVolume pot Taper(lin/log)linearfunctionalInput ConfigurationLine In(L,
23、C,R,AC3,Mono)L,RfunctionalEnabled w/Line/Spkr Input Select SwitchLine Outputs (L,C,R)L,RfunctionalBuffered Output /Pre-Volume controlSpkr/Hi Level In(L,C,R,mono)L,RfunctionalEnabled w/Line/Spkr Input Select SwitchSpkr Out: Hi Pass Filter100Hzfunctional8 ohm Satellite: 6dB/octpassive xoverDriven from
24、 zero ohmssource impedanceSignal-PresentLEDYesBi-Color LED(green=signal/ red=nosignal)Signal-Present InputFreq.100HzfunctionalNominal200uF Series Cap onPCBSignal-Present Level35mVfunctional100Hz into Line Input w/1 ch. drivenPower on Delay time2sec.AC Power AppliedTransients/PopsTurn-on/off Transien
25、t500mV-peak2v-pp Speaker OutputsAC Line cycled from OFFto ON or ON to OffEfficiencyStand-by Input Power14Watts nom. line voltagePower Cons.ratedpower110Watts nom. line voltageEfficiency136%Relative to rated outputProtectionShort Circuit ProtectionyesfunctionalDirect short at outputLineBU120HTS-20Fus