Fostex-PD6-dlr-sm维修电路原理图.pdf
《Fostex-PD6-dlr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Fostex-PD6-dlr-sm维修电路原理图.pdf(84页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service ManualModelPD-6DVD LOCATION RECORDERVISIBLE OR INVISIBLE LASER RADIATION WHEN OPEN.AVOID DIRECT EXPOSURE TO BEAM.Use of controls or adjustments or performance of proceduresother than those specified herein may result in hazardousradiation exposure. The use of optical instruments with this pr
2、oduct will increaseeye hazard.RadioFans.CN 收音机爱 好者资料库SAFETY INSTRUCTIONSRead instructions - All the safety and operating instruc-tions should be read before the appliance is operated.Retain instructions - The safety and operating instructionsshould be retained for future reference.Heed warnings - Al
3、l warnings on the appliance and in theoperating instructions should be adhered to.Follow instructions - All operating and use instructionsshould be followed.Water and Moisture - The appliance should not be usednear water - for example, near a bathtub, washbowl,kitchen sink, laundry tub, in a wet bas
4、ement, or near aswimming pool, and the like.Carts and Stands - The appliance should be used onlywith a cart or stand that is recommended by the manufac-turer.An appliance and cart combination should be moved withcare. Quick stops, excessive force, and uneven surfacesmay cause the appliance and cart
5、combination to over-turn.Wall or Ceiling Mounting - The appliance should bemounted to a wall or ceiling only as recommended by themanufacturer.Ventilation - The appliance should be situated so that itslocation or position does not interfere with its proper ven-tilation. For example, the appliance sh
6、ould not be situ-ated on a bed, sofa, rug, or similar surface that may blockthe ventilation openings; or, placed in a built- in installa-tion, such as a bookcase or cabinet that may impede theflow of air through the ventilation openings.Heat - The appliance should be situated away from heatsources s
7、uch as radiators, heat registers, stoves, or otherappliances (including amplifiers) that produce heat.Power Sources - The appliance should be connected to apower supply only of the type described in the operatinginstructions or as marked on the appliance.Grounding or Polarization - The precautions t
8、hat shouldbe taken so that the grounding or polarization means ofan appliance is not defeated.Power Cord Protection - Power supply cords should berouted so that they are not likely to be walked on orpinched by items placed upon or against them, payingparticular attention to cords at plugs, convenien
9、ce recep-tacles, and the point where they exit from the appliance.Cleaning - The appliance should be cleaned only as rec-ommended by the manufacturer.Nonuse Periods - The power cord of the appliance shouldbe unplugged from the outlet when left unused for a longperiod of time.Object and Liquid Entry
10、- Care should be taken so thatobjects do not fall and liquids are not spilled into the en-closure through openings.Damage requiring Service - The appliance should be ser-viced by qualified service personnel when:A.B.C.D.E.Servicing - The user should not attempt to service the ap-pliance beyond that
11、described in the operating instruc-tions. All other servicing should be referred to qualifiedservice personnel.REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.CAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,DO NOT REMOVE COVER (OR BACK).NO USER- SERVICEABLE PARTS
12、 INSIDE.TO PREVENT ELECTRIC SHOCK, MATCHWIDE BLADE OF PLUG TO WIDE SLOT,FULLY INSERT.POUR VITER LES CHOCS LECTRIQUES,INTRODUIRE LA LAME LA PLUS LARGE DELA FICHE DANS LA BORNE CORRE-SPONDANTE DE LA PRISE ET POUSSERJUSQU AU FOND.CAUTION:ATTENTION:The exclamation point within an equilateraltriangle is
13、intended to alert the user to thepresence of important operating and mainte-nance (servicing) instructions in the litera-ture accompanying the appliance.The lightening flash with arrowhead symbol,within an equilateral triangle, is intended toalert the user to the presence of uninsulated“dangerous vo
14、ltage” within the productsenclosure that may be of sufficient magni-tude to constitute a risk of electric shock topersons.“WARNING”“TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS-TURE.”1.2.3.4.5.6.7.8.The power supply cord or the plug has been damaged;orObj
15、ects have fallen, or liquid has been spilled into theappliance; orThe appliance has been exposed to rain; orThe appliance does not appear to operate normally orexhibits a marked changed in performance; orThe appliance has been dropped, or the enclosuredamaged.9.10.11.12.13.14.15.16.17.RadioFans.CN 收
16、音机爱 好者资料库3PD-6 Service ManualParts marked with this sign are safety critical components. They must always be replaced with identicalcomponents. Refer to the Fostex Parts List and ensure exact replacement.CAUTIONTABLE OF CONTENTSNOTES*Service menus, exploded view, PCB assembly, parts list and circuit
17、 diagrams are given in this manual to assistthe service technician in maintaining the Model PD-6.*The following accessories are supplied with PD-6 as the standard accessories.PD-6 owners manual, English: 8288498000PD-6 owners manual, Japanese: 8288499000PD-6 owners manual supplement, 1.01, ENG: 8289
18、602000PD-6 owners manual supplement, 1.01, JPN: 8289603000PD-6 owners manual supplement, 1.02, ENG: 8289604000PD-6 owners manual supplement, 1.02, JPN: 8289605000Shoulder belt assy: 8260374200DVD-RAM disk, DRMS-V28R 1P: 8266097000*Following is the packing material for the Model PD-6.Carton, inner, P
19、D-6: 8228753000Carton, outer, PD-6: 8228932000Packing, side, L, PD-6: 8228477001Packing, side, R, PD-6: 82284770021.2.3.4.5.6.7.8.48111421225283SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CONTROLS, INDICATORS & CONNECTOR
20、S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SOFTWARE UPDATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SERVICE MENUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21、. . . .ERROR CODE LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .EXPLODED VIEW, PCB ASSEMBLY & PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . .CIRCUIT & BLOCK DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . .
22、 . . . . . . . . . . . . . . . .LOCATION OF IDENTIFICATION / CERTIFICATION LABEL . . . . . . . . . . . . . . . . . .4PD-6 Service Manual1. SPECIFICATIONSSPECIFICATION UNIT0 dBu = 0.775 V r.m.s.INPUT & OUTPUTREFERENCE LEVEL-18 dB / -20 dB (default) (Switchable by SETUP mode)ANALOG INPUT (CH 1 6)Conne
23、ctorXLR-3-31 type (Pin 1: GND, Pin 2: HOT, Pin 3: COLD)Input Impedance10 k or moreLINEInput Level- 30 + 4 dBu ( 5 dB)Maximum Input Level (REF: -20 dB)+ 24 dBu (+ 41 dBu (pre fader)MICInput Level- 60 - 26 dBu ( 5 dB)Maximum Input Level (REF: -20 dB)- 40 dBu (- 23 dBu (pre fader)ANALOG OUTPUT (TRK 1 6
24、)ConnectorXLR-3-32 type (Pin 1: GND, Pin 2: HOT, Pin 3: COLD)Load Impedance10 k or moreStandard Output Level+ 4 dBuMaximum Output Level+ 24 dBuAUX I/OConnectorHirose RM15TRD-10S, femaleInputBalanced audio input for monitoring purposeInput Impedance10 k or moreStandard Input Level+ 4 dBuMaximum Input
25、 Level+ 24 dBuOutputBalanced ST BUSS OUTLoad Impedance10 k or moreStandard Output Level+ 4 dBu / - 10 dBu / - 60 dBu (switchable)Maximum Output Level+ 24 dBuDIGITAL I/O (CH 1 6)ConnectorD-SUB 25-pinFormatInputDetect either IEC60958 PART 3 (AES/EBU) or IEC60958PART 2 (S/P DIF) automaticallyOutputEith
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Fostex PD6 dlr sm 维修 电路 原理图