1、X-24Service ManualModelmultitrackerRadioFans.CN 收音机爱 好者资料库SAFETY INSTRUCTIONSRead instructions - All the safety and operating instruc-tions should be read before the appliance is operated.Retain instructions - The safety and operating instructionsshould be retained for future reference.Heed warnings
2、 - All warnings on the appliance and in theoperating instructions should be adhered to.Follow instructions - All operating and use instructionsshould be followed.Water and Moisture - The appliance should not be usednear water - for example, near a bathtub, washbowl,kitchen sink, laundry tub, in a we
3、t basement, or near aswimming pool, and the like.Carts and Stands - The appliance should be used onlywith a cart or stand that is recommended by the manufac-turer.An appliance and cart combination should be moved withcare. Quick stops, excessive force, and uneven surfacesmay cause the appliance and
4、cart combination to over-turn.Wall or Ceiling Mounting - The appliance should bemounted to a wall or ceiling only as recommended by themanufacturer.Ventilation - The appliance should be situated so that itslocation or position does not interfere with its proper ven-tilation. For example, the applian
5、ce should not be situ-ated on a bed, sofa, rug, or similar surface that may blockthe ventilation openings; or, placed in a built-in installa-tion, such as a bookcase or cabinet that may impede theflow of air through the ventilation openings.Heat - The appliance should be situated away from heatsourc
6、es such as radiators, heat registers, stoves, or otherappliances (including amplifiers) that produce heat.Power Sources - The appliance should be connected to apower supply only of the type described in the operatinginstructions or as marked on the appliance.Grounding or Polarization - The precautio
7、ns that shouldbe taken so that the grounding or polarization means ofan appliance is not defeated.Power Cord Protection - Power supply cords should berouted so that they are not likely to be walked on orpinched by items placed upon or against them, payingparticular attention to cords at plugs, conve
8、nience recep-tacles, and the point where they exit from the appliance.Cleaning - The appliance should be cleaned only as rec-ommended by the manufacturer.Nonuse Periods - The power cord of the appliance shouldbe unplugged from the outlet when left unused for a longperiod of time.Object and Liquid En
9、try - Care should be taken so thatobjects do not fall and liquids are not spilled into the en-closure through openings.Damage requiring Service - The appliance should be ser-viced by qualified service personnel when:A.B.C.D.E.Servicing - The user should not attempt to service the ap-pliance beyond t
10、hat described in the operating instruc-tions. All other servicing should be referred to qualifiedservice personnel.REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.CAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,DO NOT REMOVE COVER (OR BACK).NO USER-SERVICEABLE PA
11、RTS INSIDE.TO PREVENT ELECTRIC SHOCK, MATCHWIDE BLADE OF PLUG TO WIDE SOLT,FULLY INSERT.POUR VITER LES CHOCS LECTRIQUES,INTRODUIRE LA LAME LA PLUS LARGE DELA FICHE DANS LA BORNE CORRE-SPONDANTE DE LA PRISE ET POUSSERJUSQU AU FOND.CAUTION:ATTENTION:The exclamation point within an equilateraltriangle
12、is intended to alert the user to thepresence of important operating and mainte-nance (servicing) instructions in the literatureaccompanying the appliance.The lightening flash with arrowhead symbol,within an equilateral triangle, is intended toalert the user to the presence of uninsulated“dangerous v
13、oltage” within the products en-closure that may be of sufficient magnitude toconstitute a risk of electric shock to persons.“WARNING”“TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS-TURE.”1.2.3.4.5.6.7.8.The power supply cord or the plug has been damaged;orO
14、bjects have fallen, or liquid has been spilled into theappliance; orThe appliance has been exposed to rain; orThe appliance does not appear to operate normally orexhibits a marked changed in performance; orThe appliance has been dropped, or the enclosuredamaged.9.10.11.12.13.14.15.16.17.RadioFans.CN
15、 收音机爱 好者资料库Parts marked with this sign are safety critical components. They must always be replaced with identical components.Refer to the Fostex Parts List and ensure exact replacement.CAUTIONTABLE OF CONTENTS1. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16、. . .2. CONTROLS, INDICATORS AND CONNECTORS . . . . . . . . . . . .3. ADJUSTING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . .4. EXPLODED VIEW, PCB ASSEMBLY AND PARTS LIST . . . . . .5. CIRCUIT & BLOCK DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . .Owners manual: 8288418000 (f
17、or export & domestic model)AC adaptor AD-12A: 8270727003 (for USA/CND): 8270727006 (for EUR): 8270727007 (for UK): 8270727010 (for JPN)Adjusting Procedures, Parts List and circuit diagrams are given in this manual to assist the service technician inmaintaining the Model X-24.NOTESThe following acces
18、sories are supplied with X-24 as the standard accessories.*Following is the packing material for the Model X-24.*Carton, inner, X-24: 8228715000Packing, L, X-24: 8228439001Packing, R, X-24: 82284390023X-244781423!4X-241. SPECIFICATIONSDEFINITIONSpecification Unit0 dBV = 1 VrmsNormal Fader PositionIn
19、put faderAt 8 1 positionConditionLINE IN / INSERT: -10 dBV / 1 kHzRecorder: Input Monitor mode (REC - PAUSE)Adjust input fader for -10 dBV at TAPE OUT.PAN: L (R)Master faderAt 8 1 positionConditionLINE IN / INSERT: -10 dBV / 1 kHzRecorder: Input Monitor mode (STOP)Adjust master fader for -10 dBV at
20、LINE OUT.PAN: L (R)MIXER SECTIONStandard InputMIC INConnectorPhone (unbalanced) / XLR (balanced)Input level-50 -10 dBVImpedance10 k or moreLINE IN / INSERT (RCV)ConnectorStereo phone (tip)Input level-10 dBVImpedance10 k or moreStandard OutputTAPE OUT 1 4ConnectorRCA pinOutput level-10 dBVLoad impeda
21、nce10 k or moreLINE OUT L, RConnectorRCA pinOutput level-10 dBVLoad impedance10 k or moreINSERT (SEND)ConnectorStereo phone (ring)Output level-10 dBVLoad impedance10 k or morePhones Max. Output Level20 mW or more (1 kHz, 16 load)Level Indication0 dB is indicated by 5-dot LED bargraph meter when inpu
22、t / outputlevel is -10 dBV with the above standard input / master faderposition settings.Frequency ResponseMIC IN (Input Level: -50 dBV)40 20 kHz 3 dB at LINE OUTMIC IN (Input Level: -10 dBV)20 20 kHz 3 dB at LINE OUTLINE IN (Input Level: -10 dBV)50 10 kHz 2 dB at PHONES (10 mW / 16 )S / N (shorted
23、by 150 resistor)MIC IN (MIC GAIN: MIC)66 dB or more at LINE OUT (DIN AUDIO)68 dB or more at LINE OUT (IHF A)MIC IN (MIC GAIN: LINE)73 dB or more at LINE OUT (DIN AUDIO)75 dB or more at LINE OUT (IHF A)X-245MIXER SECTION (continued)Distortion(With 400 Hz HPF & 30 kHz LPF)0.05 % or less (Input: 1 kHz
24、/ 0 dBV signal, MIC GAIN: LINE, LINEOUT: 0 dBV.)0.2 % or less (Input: 1 kHz / 0 dBV signal, MIC GAIN:LINE,PHONES: 3 mW / 16.)Fader Attenuation70 dB or more at 1 kHz (from standard fader position)Crosstalk60 dB or more at 1 kHz (Input: MIC IN, MIC GAIN: LINE, OUT: SENDOUT. Measure level at non-input
25、channel.)PAN Crosstalk42 dB or more at 1 kHz (Input: MIC IN, MIC GAIN: LINE, OUT: LINEOUT. Measure level at non-input channel.)Click NoisePower on / off-20 dBVp-p or lessOther switching-30 dBVp-p or lessShock Noise-30 dBVp-p or less (Measure noise level when one side of appliance isdropped 3 times f