1、NADSERVICE MANUAL D3020 Hybrid Digital AmplifierrRadioFans.CN 收音机爱 好者资料库TABLE OF CONTENTS DESCRIPTION PAGE SERVICE CAUTION.3-4SPECIFICATIONS.5WIRING DIAGRAM.6 BLOCK DIAGRAM. .7-10 .12-21 PCB LAYOUT.22-29ELECTRICAL PARTS LIST.30-50 EXPLODED VIEWS 51-52EXPLODED VIEW PARTS LISTS 51-52 CIRCUIT DIAGRAMST
2、ROUBLE SHOOTING GUIDE.11RadioFans.CN 收音机爱 好者资料库PRODUCT SAFETY SERVICING GUIDELINES CAUTION : DO NOT ATTEMPT TO MODIFY THIS PRODUCT INANY WAY. NEVER PERFORM CUSTOMIZED INSTALLATIONSWITHOUT MANUFACTURERS APPROVAL. UNAUTHORIZEDMODIFICATIONS WILL NOT ONLY VOID THE WARRANTY, BUTMAY LEAD TO YOUR BEING LIA
3、BLE FOR ANY RESULTINGPROPERTY DAMAGE OR USER INJURY.SERVICE WORK SHOULD BE PERFORMED ONLY AFTER YOUARE THOROUGHLY FAMILIAR WITH ALL OF THE FOLLOWINGSAFETY CHECKS AND SERVICING GUIDELINES. TO DOOTHERWISE, INCREASES THE RISK OF POTENTIAL HAZARDSAND INJURY TO THE USER. WHILE SERVICING, USE AN ISOLATION
4、 TRANSFORMER FORPROTECTION FROM AC LINE SHOCK.SAFETY CHECKSAFTER THE ORIGINAL SERVICE PROBLEM HAS BEENCORRECTED. A CHECK SHOULD BE MADE OF THEFOLLOWING.SUBJECT : FIRE & SHOCK HAZARD1. BE SURE THAT ALL COMPONENTS ARE POSITIONED INSUCH A WAY AS TO AVOID POSSIBILITY OF ADJACENTCOMPONENT SHORTS. THIS IS
5、 ESPECIALLY IMPORTANTON THOSE MODULES WHICH ARE TRANSPORTED TO ANDFROM THE REPAIR SHOP. 2. NEVER RELEASE A REPAIR UNLESS ALL PROTECTIVEDEVICES SUCH AS INSULATORS, BARRIERS, COVERS,SHIELDS, STRAIN RELIEFS, POWER SUPPLY CORDS, ANDOTHER HARDWARE HAVE BEEN REINSTALLED PERORIGINAL DESIGN. BE SURE THAT TH
6、E SAFETY PURPOSEOF THE POLARIZED LINE PLUG HAS NOT BEEN DEFEATED.3. SOLDERING MUST BE INSPECTED TO DISCOVER POSSIBLECOLD SOLDER JOINTS, SOLDER SPLASHES OR SHARPSOLDER POINTS. BE CERTAIN TO REMOVE ALL LOOSEFOREIGN PARTICLES.4. CHECK FOR PHYSICAL EVIDENCE OF DAMAGE ORDETERIORATION TO PARTS AND COMPONE
7、NTS. FORFRAYED LEADS, DAMAGED INSULATION (INCLUDING ACCORD). AND REPLACE IF NECESSARY FOLLOW ORIGINALLAYOUT, LEAD LENGTH AND DRESS.5. NO LEAD OR COMPONENT SHOULD TOUCH A RECEIVINGTUBE OR A RESISTOR RATED AT 1 WATT OR MORE. LEADTENSION AROUND PROTRUDING METAL SURFACES MUSTBE AVOIDED.6. ALL CRITICAL C
8、OMPONENTS SUCH AS FUSES,FLAMEPROOF RESISTORS, CAPACITORS, ETC. MUST BEREPLACED WITH EXACT FACTORY TYPES, DO NOT USEREPLACEMENT COMPONENTS OTHER THAN THOSESPECIFIED OR MAKE UNRECOMMENDED CIRCUITMODIFICATIONS.7. AFTER RE-ASSEMBLY OF THE SET ALWAYS PERFORM ANAC LEAKAGE TEST ON ALL EXPOSED METALLIC PART
9、S OFTHE CABINET, (THE CHANNEL SELECTOR KNOB, ANTENNATERMINALS. HANDLE AND SCREWS) TO BE SURE THE SETIS SAFET TO OPERATE WITHOUT DANGER OF ELECTRICALSHOCK. DO NOT USE A LINE ISOLATION TRANSFORMERDURING THIS TEST USE AN AC VOLTMETER, HAVING 5000OHMS PER VOLT OR MORE SENSITIVITY, IN THEFOLLOWING MANNER
10、; CONNECT A 1500 OHM 10 WATTRESISTOR, PARALLELED BY A .15 MFD, 150V AC TYPECAPACITOR BETWEEN A KNOWN GOOD EARTH GROUND(WATER PIPE, CONDUIT, ETC.) AND THE EXPOSEDMETALLIC PARTS, ONE AT A TIME. MEASURE THE AC VOLTAGE ACROSS THE COMBINATIONOF 1500 OHM RESISTOR AND .15 MFD CAPACITOR. REVERSE THE AC PLUG
11、 AND REPEAT AC VOLTAGEMEASUREMENTS FOR EACH EXPOSED METALLIC PART. VOLTAGE MEASURE MUST NOT EXCEED 75 VOLTS R.M.S.THIS CORRESPONDS TO 0.5 MILLIAMP AC ANY VALUEEXCEEDING THIS LIMIT CONSTITUTES A POTENTIALSHOCK HAZARD AND MUST BE CORRECTED IMMEDIATELY.SUBJECT : GRAPHIC SYMBOLSSUBJECT : TIPS ON PROPER
12、INSTALLATION1. NEVER INSTALL ANY PRODUCT IN A CLOSED-IN RECESS,CUBBYHOLE OR CLOSELY FITTING SHELF SPACE. OVEROR CLOSE TO HEAT DUCT, OR IN THE PATH OF HEATEDAIR FLOW.2. AVOID CONDITIONS OF HIGH HUMIDITY SUCH AS:OUTDOOR PATIO INSTALLATIONS WHERE DEW IS AFACTOR, NEAR STEAM RADIATORS WHERE STEAMLEAKAGE
13、IS A FACTOR, ETC.3. AVOID PLACEMENT WHERE DRAPERIES MAY OBSTRUCTREAR VENTING. THE CUSTOMER SHOULD ALSO AVOID THEUSE OF DECORATIVE SCARVES OR OTHER COVERINGSWHICH MIGHT OBSTRUCT VENTILATION.4. WALL AND SHELF MOUNTED INSTALLATIONS USING ACOMMERCAL MOUNTING KIT MUST FOLLOW THE FACTORYAPPROVED MOUNTING
14、INSTRUCTIONS A PRODUCTMOUNTED TO A SHELF OR PLATFORM MUST RETAIN ITSORIGINAL FEET (OR THE EQUIVALENT THICKNESS INSPACERS) TO PROVIDE ADEQUATE AIR FLOW ACROSSTHE BOTTOM, BOLTS OR SCREWS USED FOR FASTENERSMUST NOT TOUCH ANY PARTS OR WIRING. PERFORMLEAKAGE TEST ON CUSTOMIZED INSTALLATIONS.5. CAUTION CU
15、STOMERS AGAINST THE MOUNTING OF APRODUCT ON SLOPING SHELF OR A TILTED POSITION,UNLESS THE PRODUCT IS PROPERLY SECURED.6. A PRODUCT ON A ROLL-ABOUT CART SHOULD BE STABLEON ITS MOUNTING TO THE CART. CAUTION THECUSTOMER ON THE HAZARDS OF TRYING TO ROLL A CARTWITH SMALL CASTERS ACROSS THRESHOLDS OR DEEP
16、PILE CARPETS.7. CAUTION CUSTOMERS AGAINST THE USE OF A CART ORSTAND WHICH HAS NOT BEEN LISTED BY UNDERWRITERSLABORATORIES, INC. FOR USE WITH THEIR SPECIFICMODEL OF TELEVISION RECEIVER OR GENERICALLYAPPROVED FOR USE WITH T.V.S OF THE SAME ORLARGER SCREEN SIZE.8. CAUTION CUSTOMERS AGAINST THE USE OF E
17、XTENSIONCORDS, EXPLAIN THAT A FOREST OF EXTENSIONSSPROUTING FROM A SINGLE OUTLET CAN LEAD TODISASTROUS CONSEQUENCES TO HOME AND FAMILY.THE LIGHTNING FLASH WITH ARROWHEAD SYMBOL, WITHIN ANEQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE USER TO THEPRESENCE OF UNINSULATED “DANGEROUS VOLTAGE” WITHIN THEP
18、RODUCTS ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TOCONSTITUTE A RISK OF ELECTRIC SHOCK.THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE ISINTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANTOPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THELITERATURE ACCOMPANYING THE APPLIANCE.3SE
19、RVICING PRECAUTIONSCAUTION : Before servicing the A/V Receiver covered by thisservice data and its supplements and addends, read and follow theSAFETY PRECAUTIONS. NOTE : if unforeseen circumstancescreate conflict between the following servicing precautions and anyof the safety precautions in this pu
20、blication, always follow the safetyprecautions.Remember Safety First:General Servicing Precautions1. Always unplug the A/V Receiver AC power cord from the ACpower source before:(1) Removing or reinstalling any component, circuit board,module, or any other assembly.(2) Disconnecting or reconnecting a
21、ny internal electrical plug orother electrical connection.(3) Connecting a test substitute in parallel with an electrolyticcapacitor.Caution : A wrong part substitution or incorrect polarity installationof electrolytic capacitors may result in an explosion hazard.2. Do not spray chemicals on or near
22、 this A/V Receiver or any of itsassemblies.3. Unless specified otherwise in this service data, clean electricalcontacts by applying an appropriate contact cleaning solution tothe contacts with a pipe cleaner, cottontipped swab, orcomparable soft applicator.Unless specified otherwise in this service
23、data, lubrication ofcontacts is not required.4. Do not defeat any plug/socket B+ voltage interlocks with whichinstruments covered by this service manual might be equipped.5. Do not apply AC power to this A/V Receiver and/or any of itselectrical assemblies unless all solid-state device heat sinks are
24、correctly installed.6. Always connect test instrument ground lead to the appropriateground before connecting the test instrument positive lead. Alwaysremove the test instrument ground lead last.Insulation Checking ProcedureDisconnect the attachment plug from the AC outlet and turn thepower on. Conne
25、ct an insulation resistance meter(500V) to theblades of the attachment plug. The insulation resistance betweeneach blade of the attachment plug and accessible conductive parts(Note 1) should be more than 1M-ohm.Note 1 : Accessible Conductive Parts including Metal panels, Inputterminals, Earphone jac