Pioneer-VSA830-avr-sm 维修电路原理图.pdf
《Pioneer-VSA830-avr-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Pioneer-VSA830-avr-sm 维修电路原理图.pdf(68页珍藏版)》请在收音机爱好者资料库上搜索。
1、ORDER NO.PIONEER CORPORATION 1-1, Shin-ogura, Saiwai-ku, Kawasaki-shi, Kanagawa 212-0031, JapanPIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A.PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, BelgiumPIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road
2、, #04-01, Singapore 159936 PIONEER CORPORATION20152015 Printed in JapanVSX-830-KRRV4595AV ReceiverVSX-830-KVSX-45VSX-830-SVSA-830THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).THIS SERVICE MANUAL SHOULD BE USED TOGETHER WITH THE FOLLOWING MANUAL(S).ModelTypePower RequirementRemarksV
3、SX-830-KCUXESMAC 120 VVSX-45CUXEAC 120 VVSX-830-KSYXEV8AC 220 V to 230 VVSX-830-SSYXEV8AC 220 V to 230 VVSA-830JXEVAC 100 VModelOrder No.RemarksVSX-830-K, VSX-45, VSX-830-SRRV4594BLOCK DIAGRAM, EXPLODED VIEWS AND PARTS LIST etc.K-MZV MAYRadioFans.CN 收音机爱 好者资料库2VSX-830-K1234ABCDEF1234SAFETY INFORMATI
4、ON WARNINGThis product may contain a chemical known to the State of California to cause cancer, or birth defects or other reproductive harm.Health & Safety Code Section 25249.6 - Proposition 65This service manual is intended for qualified service technicians; it is not meant for the casual do-it-you
5、rselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual.Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty.
6、 If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician.1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service techn
7、ician.LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal ov
8、erlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120 V AC 60 Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5 mA.ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECT
9、ED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER.2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using re
10、placement components rated for voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with a on the schematics and on the parts list in this Service Manual.Th
11、e use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product Safety is continuously under review and new instructions are i
12、ssued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER. LeakagecurrenttesterReading shouldnot be above0.5 mADeviceundertestTest allexpo
13、sed metalsurfacesAlso test withplug reversed(Using AC adapterplug as required)EarthgroundAC Leakage Test(FOR USA MODEL ONLY)RadioFans.CN 收音机爱 好者资料库3VSX-830-K56785678ABCDEFCONTENTS SAFETY INFORMATION.210. SCHEMATIC DIAGRAM.410.1 OVERALL WIRING DIAGRAM .410.2 MAIN ASSY (1/2).610.3 MAIN ASSY (2/2).810.
14、4 D-MAIN ASSY (1/8).1010.5 D-MAIN ASSY (2/8).1210.6 D-MAIN ASSY (3/8).1410.7 D-MAIN ASSY (4/8).1610.8 D-MAIN ASSY (5/8).1810.9 D-MAIN ASSY (6/8).2010.10 D-MAIN ASSY (7/8).2210.11 D-MAIN ASSY (8/8).2410.12 OPTCO ASSY .2610.13 SP-B ASSY (VSX-45/CUXE ONLY).2610.14 CONCT ASSY .2710.15 CPU ASSY.2810.16 A
15、MP5 ASSY (1/2).3010.17 AMP5 ASSY (2/2).3210.18 FUSB ASSY.3410.19 NTC, FRONT, HPMIC and INSEL ASSYS.3610.20 SMPS ASSY.3810.21 REG ASSY .4011. PCB CONNECTION DIAGRAM.4211.1 MAIN ASSY.4211.2 DMAIN ASSY.4611.3 OPTCO and SP-B ASSYS.5011.4 CONCT ASSY .5111.5 CPU ASSY.5211.6 AMP5 ASSY .5611.7 FUSB, NTC, FR
16、ONT, HPMIC and INSEL ASSYS.5811.8 SMPS ASSY.6211.9 REG ASSY .6312. PCB PARTS LIST.644VSX-830-K1234ABCDEF123410. SCHEMATIC DIAGRAM10.1 OVERALL WIRING DIAGRAMBEECBBCEEECBECB(S2)(S3)AC-IN(S4)(S1)CN403CP1CN3CN9502CX101CX102CX100CN1CN1805CP2009CP7CP3CP2CP403CN7202BCN3004CN7202ACP3501ACN5CP5CP3501BCP402CC
17、MAIN TRANSVSX-45 ONLYAC IN2SD2Q6Q5SRQ7SRKTC39642SB15602SD2390Q6FRQ5FRQ7FRKTC39642SB1560GGG1/2,2/2COPTCO A(VSX-830-K(VSX-45/CU(VSX-830-K(VSA-830/JDSP-B ASSY(7028077732010)AMP5 A(VSX-830(VSA-830/INTC ASSY(VSX-830-K/CUXESM: 7028077725050)(VSX-45/CUXE: 7028077725010)(VSX-830-K,-S/SYXEV8: 7028077725040)(
18、VSA-830/JXEV: 7028077725060)KHPMIC ASSY(VSX-830-K/CUXESM: 7028077724050(VSX-45/CUXE: 7028077724010)(VSX-830-K,-S/SYXEV8: 70280777240(VSA-830/JXEV: 7028077724060)LINSEL ASSY(VSX-830-K/CUXESM: 7028077722050)(VSX-45/CUXE: 7028077722010)(VSX-830-K,-S/SYXEV8: 7028077722040)(VSA-830/JXEV: 7028077722060)MS
19、MPS ASSY(VSX-830-K/CUXESM, VSX-45/CUXE: 70280733610GA)(VSX-830-K,-S/SYXEV8: 70280733610HA)(VSA-830/JXEV: 70280733610IA)NREG ASSY(VSX-830-K/CUXESM: 7028077712030)(VSX-45/CUXE: 7028077712010)(VSX-830-K,-S/SYXEV8: 7028077712020)(VSA-830/JXEV: 7028077712040)5VSX-830-K56785678ABCDEFBCEEBECBEBECBBCEECBBCA
20、GNDV+5VAGNDEECBBCEECBA+12VACWPA-12VCP313CN610CN302CN611CN303BCN313BCP312CN312CP311CN311CP310CN310CN9502W7CN2CN602CN301CP113CN114CP114CN113CN105CN1801CN9503CN9202CP3601CN314CN308BCP404CN305CN801CN802CP3002CN3001CN1805CP2009CP115CN1CP401CCUSB+12VUSB+12VUSBGNDUSBGNDAGND-RLYUSB+12VUSBGNDTR+12VTUNER PACK
21、- When ordering service parts, be sure to refer to EXPLODED VIEWS and PARTS LIST or PCB PARTS LIST.- The mark found on some component parts indicates the importance of the safety factor of the part. Therefore, when replacing, be sure to use parts of identical designation.- : The power supply is show
22、n with the marked box. CP402CP36022SD2390Q6FLQ5FLQ7FLKTC39642SB15602SD2390Q6SLQ5SLQ7SLKTC39642SB15602SD2390Q6SRQ5SRKTC39642SD2390Q6CQ5CQ7CKTC39642SB1560AAA1/2,2/2MAIN ASSY(VSX-830-K/CUXESM: 7028077711030)(VSX-45/CUXE: 7028077711010)(VSX-830-K,-S/SYXEV8: 7028077711020)(VSA-830/JXEV: 7028077711040)2/2
23、BBB1/8-8/8DMAIN ASSY(VSX-830-K/CUXESM: 7028077771030)(VSX-45/CUXE: 7028077771010)(VSX-830-K,-S/SYXEV8: 7028077771020)(VSA-830/JXEV: 7028077771040)COPTCO ASSY(VSX-830-K/CUXESM: 7028077723050)(VSX-45/CUXE: 7028077723010)(VSX-830-K,-S/SYXEV8: 7028077723040)(VSA-830/JXEV: 7028077723060)ECONCT ASSY(VSX-8
24、30-K/CUXESM: 7028077713030)(VSX-45/CUXE: 7028077713010)(VSX-830-K,-S/SYXEV8: 7028077713020)(VSA-830/JXEV: 7028077713040)FCPU ASSY(VSX-830-K/CUXESM: 7028077731050)(VSX-45/CUXE: 7028077731010)(VSX-830-K,-S/SYXEV8: 7028077731040)(VSA-830/JXEV: 7028077731060)AMP5 ASSY(VSX-830-K/CUXESM, VSX-45/CUXE, VSX-
25、830-K,-S/SYXEV8: 7028074541040)(VSA-830/JXEV: 7028074541060)HFUSB ASSY(VSX-830-K/CUXESM: 7028077731040)(VSX-45/CUXE: 7028077781010)(VSX-830-K,-S/SYXEV8: 7028077781030)(VSA-830/JXEV: 7028077731050)JFRONT ASSY(VSX-830-K/CUXESM: 7028077721050)(VSX-45/CUXE: 7028077721010)(VSX-830-K,-S/SYXEV8: 7028077721