JVC-THC6-ddcs-sm 维修电路原理图.pdf
《JVC-THC6-ddcs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-THC6-ddcs-sm 维修电路原理图.pdf(81页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4282005/7DVD DIGITAL CINEMA SYSTEMMB42820057TH-C6Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-84ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-305TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35Area suffixA - AustraliaUW - Brazil,Mexico,PeruUY - ArgentinaUJ - U.S.MilitaryUG - Turkey,South Africa,Egypt(XV-THC6)(SP-PWC6)(SP-THC6F)(SP-THC6F) (SP-THC6C)(SP-THC6S)RadioFans.CN 收音机爱 好者资料库1-2 (No.MB428)SPECIFIC
5、ATIONCenter unit (XV-THC9/XV-THC6/XV-THC3)*1: This value is measured at System cord CONNECTOR for reference.*2: Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz)Subwoofer (SP-PWC6/SP-PWC3)Audio section Total Harmonic Distortion *
6、10.02%Digital input*2 DIGITAL IN (DBS)(OPTICAL)-21 dBm to -15 dBm(660 nm 30 nm)Video section Video SystemPAL/NTSCHorizontal Resolution500 linesSignal-to-Noise Ratio64 dBVideo output levelComposite: 1.0 V(p-p)/75 S-video-Y: 1.0 V(p-p)/75 S-video-C: For PAL: 0.3 V(p-p)/75 S-video-C: For NTSC: 0.286 V(
7、p-p)/75 Component-Y: 1.0 V(p-p)/75 Component-PB/PR: 0.7 V(p-p)/75 Video input sensitivity/Impedance (VCR IN) Composite: 1.0 V(p-p)/75 S-video-Y: 1.0 V(p-p)/75 S-video-C: For PAL: 0.3 V(p-p)/75 S-video-C: For NTSC: 0.286 V(p-p)/75 Tuner section Tuning Range FM87.5 MHz to 108.0 MHzAM (Except for Middl
8、e East) 531 kHz to 1 710 kHz (at 9 kHz channel spacing)530 kHz to 1 710 kHz (at 10 kHz channel spacing)AM (For Middle East)531 kHz to 1 602 kHz (at 9 kHz channel spacing)530 kHz to 1 600 kHz (at 10 kHz channel spacing)GeneralPower RequirementsAC 110-240 V , 50/60 HzPower Consumption19 W (at operatio
9、n)1.9 W (in standby mode)Dimensions (W H D)400 mm 85 mm 399 mmMass4.2 kgAmplifier section Front140W per channel, RMS at 4 at 1 kHz, with 10% total harmonic dis-tortion.Center/Surround130W per channel, RMS at 4 at 1 kHz, with 10% total harmonic dis-tortion.Subwoofer140 W, RMS at 4 at 100 Hz, with 10%
10、 total harmonic distortion.Speaker section Speaker unit16 cm Bass-reflexPower Handling Capacity140 WImpedance4 Frequency Range30 Hz to 200 HzGeneralPower Requirements Except for Australia AC 110 V/ AC 127 V/AC 220-240 V , 50/60 HzFor Australia onlyAC 240 V , 50 HzPower Consumption135 W (at operation
11、)0 W (in standby mode)Dimensions (W H D)169 mm 411 mm 459 mmMass11.3 kgRadioFans.CN 收音机爱 好者资料库(No.MB428)1-3Satellite Speakers (SP-XTHC6)Designs & specifications are subject to change without notice.Front speakers (SP-THC6F)Speaker unit5.5 cm 2, 1.5 cm, Bass-reflex, Magnetically ShieldedPower Handlin
12、g Capacity 140 WImpedance4 Frequency Range90 Hz to 20 kHzDimensions (W H D)250 mm 1 104 mm 250 mmMass2.6 kg eachCenter speaker (SP-THC6C)Speaker unit5.5 cm 2, 1.5 cm, Bass-reflex, Magnetically ShieldedPower Handling Capacity 140 WImpedance4 Frequency Range90 Hz to 20 kHzDimensions (W H D)320 mm 75 m
13、m 92 mmMass0.9 kgSurround speakers (SP-THC6S) Speaker unit5.5 cm 2, 1.5 cm, Bass-reflexPower Handling Capacity 140 WImpedance4 Frequency Range90 Hz to 20 kHzDimensions (W H D)250 mm 1 142 mm 250 mmMass2.6 kg each1-4 (No.MB428)SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product co
14、ntains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services shoul
15、d be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of respons
16、ibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by
17、 us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts L
18、ist in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clam
19、ps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have bee
20、n returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis
21、 safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal par
22、t having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 1
23、0W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chas
24、sis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international s
25、afety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selec