JVC-RXD402B-avr-sch 维修电路原理图.pdf
《JVC-RXD402B-avr-sch 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RXD402B-avr-sch 维修电路原理图.pdf(87页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4482005/9AUDIO/VIDEO CONTROL RECEIVERMB44820059RX-D402B, RX-D401SLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-195TROUBLESHOOTING . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19Area suffixJ - U.S.A.RadioFans.CN 收音机爱 好者资料库1-2 (No.MB448)SPECIFICATION*Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz).Designs and specific
5、ations are subject to change without notice.AmplifierOutput Power At stereo operationFront channels110 W per channel, min. RMS, driven into 6 at 20 Hz to 20 kHz with no more than 0.8% total harmonic distortion.At surround operationFront channels110 W per channel, min. RMS, driven into 6 at 1 kHz wit
6、h no more than 0.8% total har-monic distortion.Center channel110 W, min. RMS, driven into 6 at 1 kHz,with no more than 0.8% total harmonic distortion.Surround channels110 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total har-monic distortion.Surround back channels110 W pe
7、r channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total har-monic distortion.AudioAudio Input Sensitivity/ImpedanceDVR/DVD, VCR, DBS, TV270 mV/47 kAudio Input(DIGITAL IN)*CoaxialDIGITAL IN 1(DVR/DVD): 0.5 V(p-p)/75 OpticalDIGITAL IN 2(DBS), 3(VCR): -21 dBm to -15 dBm (660 nm 30 nm)
8、USBUSBAudio Output LevelDVR, VCR270 mVSignal-to-Noise Ratio (66 IHF/78 IHF)80 dB/62 dBFrequency Response (6 )20 Hz to 20 kHz (1 dB)Bass Boost+4 dB 1 dB at 100 HzEqualization(at DSP operation)Center frequency63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHzControl range8 dBVideoVideo Input Sensitivity/ImpedanceCom
9、posite video:DVR/DVD, VCR, DBS1 V(p-p)/75 S-video:DVR/DVD, VCR, DBSY (luminance): 1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:DVR/DVD, VCR (DBS)Y (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 Video Output Level/ImpedanceComposite video: DVR, VCR, MONITOR OUT 1 V(p-p)/75 S-video: DV
10、R, VCR, MONITOR OUTY (luminance): 1 V(p-p)/75 C (chrominance, burst): 0.286 V(p-p)/75 Component: MONITOR OUTY (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 SynchronizationNegativeHDMIHDMI Input (Ver. 1.1)VCR (DBS), DVR/DVDHDMI Output (Ver. 1.0)MONITOR OUTFM tuner (IHF) Tuning Range87.5 MHz to 108.0
11、 MHzUsable SensitivityMonaural12.8 dBf (1.2 V/75 )50 dB Quieting SensitivityMonaural16.0 dBf (1.7 V/75 )Stereo37.5 dBf (20.5 V/75 )Stereo Separation at REC OUT35 dB at 1 kHzAM tunerTuning Range530 kHz to 1 710 kHzGeneralPower RequirementsAC 120 V , 60 HzPower Consumption150 W/200 VA (at operation)0.
12、9 W (in standby mode)Dimensions (W H D)435 mm 91.5 mm 371 mm (17 3/16 inch-es 3 5/8 inches 14 5/8 inches)Mass7.1 kg (15.7 lbs)RadioFans.CN 收音机爱 好者资料库(No.MB448)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components speciall
13、y for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of t
14、he design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefro
15、m.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-ag
16、e, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement wh
17、ich does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive part
18、s, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock haza
19、rd testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a
20、line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth grou
21、nd. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex
22、-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse
23、 the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repair
24、er to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs
25、formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-RXD402B-avr-sch 维修电路原理图 JVC RXD402B avr sch 维修 电路 原理图