JVC-RX6042S-avr-sm1 维修电路原理图.pdf
《JVC-RX6042S-avr-sm1 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RX6042S-avr-sm1 维修电路原理图.pdf(48页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB2672004/6AUDIO/VIDEO CONTROL RECEIVERMB26720046RX-6042STABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32S
2、PECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-54AD
3、JUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-135TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. 1-14TA/NEWS/INFODISPLAY MODE Area suffixA - AusitraliaRadioFans.CN 收音机爱 好者资料库1-2 (No.MB267)SPECIFICATION*1: Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency-32 kHz, 44.1 kHz, 48 kHz)Designs and specifications are subject to change without notice.Amplifi
5、erOutput PowerAt Stereo operationFront channels100 W per channel, min. RMS, driven into 8 , 40 Hz to 20 kHz with no morethan 0.8% total harmonic distortion.At Surround operationFront channels100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than0.8% total harmonic distortion.Center
6、channel100 W, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% totalharmonic distortion.Surround chan-nels100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than0.8% total harmonic distortion.AudioAudio Input Sensitivity/Impedance (1 kHz)CD, TAPE/CDR, VCR, TV SOUND, DVD:220
7、mV/47 kAudio Input (DIGITAL IN)*1CoaxialDIGITAL 1 (DVD)OpticalDIGITAL 2 (CD), DIGITAL 3 (TV):-21 dBm to -15 dBm (660 nm 30 nm)Recording Output LevelTAPE/CDR, VCR:220 mVSignal-to-Noise Ratio (66 IHF/78 IHF)CD, TAPE/CDR, VCR, TV SOUND, DVD:87 dB/62 dBFrequency Response (8 )CD, TAPE/CDR, VCR, TV SOUND,
8、 DVD:20 Hz to 50 kHz (+1 dB, -3 dB)Bass Boost+3 dB 1 dB at 100 HzEqualization (5 bands) 63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz:8 dB (in 2 dB steps)VideoVideo Input Sensitivity/ImpedanceComposite video:DVD, VCR1 V(p-p)/75 S-video:DVD, VCR(Y: luminance):1 V(p-p)/75 (C: chrominance, burst):0.286 V(p-p)/75
9、 ComponentDVD, VCR(Y: luminance):1 V(p-p)/75 (PB, PR):0.7 V(p-p)/75 Video Output LevelComposite video:VCR, MONITOROUT1 V(p-p)/75 S-video:VCR, MONITOR OUT(Y: luminance):1 V(p-p)/75 :0.286 V(p-p)/75 (C: chrominance, burst)ComponentMONITOR OUT(Y: luminance):1 V(p-p)/75 (PB, PR)0.7 V(p-p)/75 Synchroniza
10、tionNegativeSignal-to-Noise Ratio45 dBRadioFans.CN 收音机爱 好者资料库(No.MB267)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safetypurposes. For continued protection, no changes should bemade to the original
11、 design unless authorized in writing bythe manufacturer. Replacement parts must be identical tothose used in the original circuits. Services should beperformed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the produ
12、ct shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related charac
13、teristics. Thesecharacteristics are often not evident from visual inspectionnor can the protection afforded by them necessarily beobtained by using replacement components rated forhigher voltage, wattage, etc. Replacement parts whichhave these special safety characteristics are identified inthe Part
14、s List of Service Manual. Electrical componentshaving such features are identified by shading on theschematics and by ( ) on the Parts List in the ServiceManual. The use of a substitute replacement which doesnot have the same safety characteristics as therecommended replacement parts shown in the Pa
15、rts List ofService Manual may create shock, fire, or other hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and fir
16、ehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, afterreassembling.(5) Leakage shock hazard testingAfter reassembling the product, always perform anisolation check on the exposed metal parts of
17、 the product(antenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeak
18、age Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet,particularly any exposed metal part having a return pathto the chassis, to a known good earth ground. Anyleakage current must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly
19、 into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between anexposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. M
20、ove the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). Thi
21、s corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsaf
22、ety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the
23、case ofpreforming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are
24、criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500
25、 10W0.15 F AC TYPE1-4 (No.MB267)SECTION 2SPECIFIC SERVICE INSTRUCTIONSThis service manual does not describe SPECIFIC SERVICE INSTRUCTIONS.(No.MB267)1-5SECTION 3DISASSEMBLY3.1Removing the top cover (See Fig.1)(1) From the right and left sides of the main body, remove thefour screws A attaching the to