JVC-RXF10S-htr-sm 维修电路原理图.pdf
《JVC-RXF10S-htr-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RXF10S-htr-sm 维修电路原理图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB2642004/6HOME THEATER RECEIVERMB26420046RX-F10STABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC
2、SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64ADJUSTMENT
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-185TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19Ar
4、ea suffixJ - U.S.A.C - CanadaRadioFans.CN 收音机爱 好者资料库1-2 (No.MB264)SPECIFICATION*1: Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz).Designs & specifications are subject to change without notice.AmplifierOutput PowerAt stereo op-erationFront chan
5、nels100 W per channel, min. RMS, both channels driven into 6 at 40 Hz to 20 kHz with no more than 0.8% total harmonic distortion.At surround operationFront channels100 W per channel, min. RMS, driven into 6 at 1 kHz with no more than 0.8% total harmonic distortion.Center channel100 W, min. RMS, driv
6、en into 6 at 1 kHz, with no more than 0.8% total harmonic distortion.Surround channels100 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion.Surround back channel100 W, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion.A
7、udioAudio Input Sensitivity/Imped-anceDVR/DVD (DVD MULTI), VCR, DBS, TV:330 mV/47 kAudio Input (DIG-ITAL IN)*1CoaxialDIGITAL IN 1(DVR/DVD):0.5 V(p-p)/75 OpticalDIGITAL IN 2(DBS), 3(VCR): -21 dBm to -15 dBm (660 nm 30 nm)Audio Output LevelDVR, VCR, MONITOR OUT:330 mVSignal-to-Noise Ratio (66 IHF/DIN)
8、80 dB/62 dBFrequency Response (6 )20 Hz to 20 kHz (1 dB)Bass Boost+4 dB 1 dB at 100 HzEqualization (at DSP operation)Center frequency:63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHzControl range:8 dBVideoVideo Input Sensitivity/Imped-anceComposite video:DVR/DVD, VCR, DBS1 V(p-p)/75 S-video:DVR/DVD, VCR, DBSY (l
9、uminance):1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:DVR/DVD, VCRY (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 Video Output Level/ImpedanceComposite video:DVR, VCR, MONITOR OUT1 V(p-p)/75 S-video:DVR, VCR, MONITOR OUTY (luminance):1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75
10、 Component:MONITOR OUTY (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 SynchronizationNegativeFM tuner (IHF)Tuning Range87.5 MHz to 108.0 MHzUsable SensitivityMonaura:12.8 dBf (1.2 V/75 )50 dB Quieting SensitivityMonaural:16.0 dBf (1.7 V/75 )Stereo:37.5 dBf (20.5 V/75 )Stereo Separation at REC OUT35 d
11、B at 1 kHzAM tunerTuning Range530 kHz to 1 710 kHzGeneralPower RequirementsAC 120 V , 60 HzPower Consumption120 W/160 VA (at operation) 2 W (in standby mode)Dimensions (W H D)435 mm 70 mm 329.5 mm (17 3/16 inches 2 13/16 inches 13 inches)Mass6.3 kg (13.9 lbs)RadioFans.CN 收音机爱 好者资料库(No.MB264)1-3SECTI
12、ON 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts mu
13、st be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manu
14、facturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspect
15、ion nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such feature
16、sare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazard
17、s.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand d
18、ress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw
19、 heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each ex
20、posed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 p
21、er volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart
22、, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) Thi
23、s equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critica
24、l components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical
25、 parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are criticalfor safety. When replacing them, be sure to