JVC-RXD202B-avr-sch 维修电路原理图.pdf
《JVC-RXD202B-avr-sch 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RXD202B-avr-sch 维修电路原理图.pdf(73页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB3642005/5AUDIO/VIDEO CONTROL RECEIVERMB36420055RX-D201S,RX-D202BLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-195TROUBLESHOOTING . . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19Area suffixRX-D201SJ - U.S.A.Area suffixRX-D202BJ - U.S.A.C - CanadaRadioFans.CN 收音机爱 好者资料库1-2 (No.MB364)SPECIFICATION* Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency
5、-32 kHz, 44.1 kHz, 48 kHz).Designs and specifications are subject to change without notice.AmplifierOutput Power At stereo operationFront channels100 W per channel, min. RMS, driven into 6 at 40 Hz to 20 kHz with no more than 0.8% total harmonic distor-tion.At surround operationFront channels100 W p
6、er channel, min. RMS, driven into 6 at 1 kHz with no more than 0.8% total harmonic distortion.Center channel100 W, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion.Surround channels100 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total har
7、monic distortion.Surround back channels100 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion.AudioAudio Input Sensitivity/ImpedanceDVR/DVD, VCR, DBS, TV:270 mV/47 kAudio Input (DIGITAL IN)*CoaxialDIGITAL IN 1(DVR/DVD):0.5 V(p-p)/75 OpticalDIGITAL IN 2(
8、DBS):-21 dBm to -15 dBm (660 nm 30 nm)USBUSB DIGITALAudio Output LevelDVR, VCR:270 mVSignal-to-Noise Ratio (66 IHF/78 IHF)80 dB/62 dBFrequency Response (6 )20 Hz to 20 kHz (1 dB)Bass Boost+4 dB 1 dB at 100 HzEqualization (at DSP operation)Center frequency63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHzControl ra
9、nge8 dBVideoVideo Input Sensitivity/Impedance Composite video:DVR/DVD, VCR, DBS 1 V(p-p)/75 S-video:DVR/DVD, VCR, DBSY (luminance):1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:DVR/DVD, VCR (DBS)Y (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 Video Output Level/ImpedanceComposite video
10、:DVR/DVD, VCR, DBS 1 V(p-p)/75 S-video:DVR, VCR, MONITOR OUTY (luminance):1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:MONITOR OUTY (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 SynchronizationNegativeFM tuner (IHF)Tuning Range87.5 MHz to 108.0 MHzUsable SensitivityMonaural12.8 dBf (1
11、.2 V/75 )50 dB Quieting SensitivityMonaural16.0 dBf (1.7 V/75 )Stereo37.5 dBf (20.5 V/75 )Stereo Separation at REC OUT35 dB at 1 kHzAM tunerTuning Range530 kHz to 1 710 kHzGeneralPower RequirementsAC 120 V , 60 HzPower Consumption150 W/200 VA (at operation)0.9 W (in standby mode)Dimensions (W H D)43
12、5 mm 91.5 mm 360 mm(17 3/16 inches 3 5/8 inches 14 3/16 inches)Mass6.7 kg (14.8 lbs)RadioFans.CN 收音机爱 好者资料库(No.MB364)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued prot
13、ection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shou
14、ldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts
15、 in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these
16、 specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-t
17、eristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts an
18、d/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product,
19、always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this che
20、ck. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0
21、.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between anexposed metal part and a known good earth gro
22、und.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each me
23、asurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are
24、maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on so
25、me partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC-RXD202B-avr-sch 维修电路原理图 JVC RXD202B avr sch 维修 电路 原理图