1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4492005/7HOME CINEMA CONTROL CENTERMB44920057RX-F31SLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-54ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-155TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15Area suffixA - AustraliaUS - SingaporeUF - ChinaUJ - U.S.MilitaryRadioFans.CN 收音机爱 好者资料库1-2 (No.MB449)SPECIFICATION*1: Measured on AC 110 V, 127 V, 220 V, and 240 V.*2: Corresponding to Linear PCM, Dolby Digit
5、al, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz).Designs and specifications are subject to change without notice.AmplifierOutput Power At stereo operationFront channels100 W*1 per channel, min. RMS, driven into 6 at 1 kHz with no more than 10% total har-monic distortion.At surround op
6、erationFront channels100 W*1 per channel, min. RMS, driven into 6 at 1 kHz with no more than 0.8% total harmonic distortion.Center channel100 W*1, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distor-tion.Surround channels100 W*1 per channel, min. RMS, driven into 6 at 1 kH
7、z with no more than 0.8% total harmonic distortion.Surround back channel100 W*1, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distor-tion.AudioAudio Input Sensitivity/ImpedanceDVR/DVD (DVD MULTI), VCR, DBS, TV330 mV/47 kAudio Input(DIGITAL IN)*2Coaxial: DIGITAL IN 1(DVR/DV
8、D)0.5 V(p-p)/75 Optical: DIGITAL IN 2(DBS), 3(VCR)-21 dBm to -15 dBm (660 nm 30 nm)Audio Output LevelDVR, VCR, MONITOR OUT330 mVSignal-to-Noise Ratio (66 IHF/DIN)80 dB/62 dBFrequency Response (8 )20 Hz to 20 kHz (1 dB)Bass Boost+4 dB 1 dB at 100 HzEqualization(at DSP operation)Center frequency63 Hz,
9、 250 Hz, 1 kHz, 4 kHz, 16 kHzControl range8 dBVideoVideo Input Sensitivity/ImpedanceComposite video: DVR/DVD, VCR, DBS1 V(p-p)/75 S-video: DVR/DVD, VCR, DBSY (luminance): 1 V(p-p)/75 C (chrominance, burst): 0.286 V(p-p)/75 Component: DVR/DVD, VCRY (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 Video
10、 Output Level/ImpedanceComposite video: DVR, VCR, MONITOR OUT 1 V(p-p)/75 S-video: DVR, VCR, MONITOR OUTY (luminance): 1 V(p-p)/75 C (chrominance, burst): 0.286 V(p-p)/75 Component: MONITOR OUTY (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 SynchronizationNegativeFM tuner (IHF) Tuning Range87.50 MH
11、z to 108.00 MHzUsable SensitivityMonaural12.8 dBf (1.2 V/75 )50 dB Quieting SensitivityMonaural16.0 dBf (1.7 V/75 )Stereo37.5 dBf (20.5 V/75 )Stereo Separation at OUT(REC)35 dB at 1 kHzAM tunerTuning Range531 kHz to 1 710 kHz (at 9 kHz intervals)530 kHz to 1 710 kHz (at 10 kHz intervals)GeneralPower
12、 RequirementsAC 110 V/127 V/220 V/230 V - 240 V , adjust-able with the voltage selector, 50 Hz/60 HzPower Consumption120 W (at operation)5 W (in standby mode)Dimensions (W H D)435 mm 70 mm 317.2 mmMass6.3 kgRadioFans.CN 收音机爱 好者资料库(No.MB449)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design o
13、f this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuit
14、s. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanuf
15、acture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessari
16、ly be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by
17、( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dress
18、ed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedt
19、hat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be s
20、ure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any
21、exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner.
22、Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a retur
23、npath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomee
24、t international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If ma
25、ins voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appe