JVC-RXD211S-avr-sch 维修电路原理图.pdf
《JVC-RXD211S-avr-sch 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RXD211S-avr-sch 维修电路原理图.pdf(59页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5252006/5AUDIO/VIDEO CONTROL RECEIVERMB52520065RX-D211SJ,RX-D212BJ,RX-D212BCLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53DISASSEMBLY . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-145TROUBLESHOOTING . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15RadioFans.CN 收音机爱 好者资料库1-2 (No.MB525)SPECIFICATION* Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz).Designs and specifications ar
5、e subject to change without notice.AmplifierOutput Power At stereo operationFront channels110 W per channel, min. RMS, driven into 6 at 20 Hz to 20 kHz with no more than 0.8% total har-monic distortion.At surround operationFront channels110 W per channel, min. RMS, driven into 6 at 1 kHz with no mor
6、e than 0.8% total harmonic dis-tortion.Center channel110 W, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion.Surround channels110 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic dis-tortion.Surround back channels110 W per chann
7、el, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic dis-tortion.AudioAudio Input Sensitivity/Impedance DVR/DVD, VCR, DBS, TV300 mV/47 kAudio Input (DIGITAL IN)*Coaxial: DIGITAL IN 1(DVR/DVD)0.5 V(p-p)/75 Optical: DIGITAL IN 2(DBS), 3(VCR)-21 dBm to -15 dBm (660 nm 30 nm)USBUS
8、B DIGITALAudio Output LevelDVR, VCR300 mVSignal-to-Noise Ratio (66 IHF/78 IHF)80 dB/70 dBFrequency Response (6 )20 Hz to 20 kHz (1 dB)Bass Boost+4 dB 1 dB at 100 HzEqualization (at DSP operation)Center frequency63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHzControl range8 dBVideoVideo Input Sensitivity/Impedanc
9、e Composite video: DVR/DVD, VCR, DBS1 V(p-p)/75 S-video: DVR/DVD, VCR, DBSY (luminance) : 1 V(p-p)/75 C (chrominance, burst) : 0.286 V(p-p)/75 Component: DVR/DVD, VCR (DBS)Y (luminance) : 1 V(p-p)/75 PB, PR : 0.7 V(p-p)/75 Video Output Level/ImpedanceComposite video: DVR, VCR, MONITOR OUT 1 V(p-p)/7
10、5 S-video: DVR, VCR, MONITOR OUTY (luminance) : 1 V(p-p)/75 C (chrominance, burst) : 0.286 V(p-p)/75 Component: MONITOR OUTY (luminance) : 1 V(p-p)/75 PB, PR : 0.7 V(p-p)/75 SynchronizationNegativeFM tuner (IHF)Tuning Range87.5 MHz to 108.0 MHzUsable SensitivityMonaural12.8 dBf (1.2 V/75 )50 dB Quie
11、ting SensitivityMonaural16.0 dBf (1.7 V/75 )Stereo37.5 dBf (20.5 V/75 )Stereo Separation at REC OUT35 dB at 1 kHzAM tunerTuning Range530 kHz to 1 710 kHzGeneralPower RequirementsAC 120 V , 60 HzPower Consumption150 W/200 VA (at operation)0.9 W (in standby mode)Dimensions (W H D)435 mm 91.5 mm 360 mm
12、(17 3/16 inches 3 5/8 inches 14 3/16 inches)Mass6.7 kg (14.8 lbs)RadioFans.CN 收音机爱 好者资料库(No.MB525)1-3SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes
13、should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any
14、design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products ha
15、vespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety char
16、acteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the rec
17、ommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for
18、 the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an i
19、sola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC lin
20、e cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). A
21、lternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the A
22、C voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltag
23、e measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Re
24、pairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the ch
25、assis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), dio