1、 PowerBass Series PB12 Powered Subwoofer Service Manual JBL Consumer Products 250 Crossways Park Dr. Woodbury, New York 11797 Rev10 2/2004 RadioFans.CN 收音机爱 好者资料库 PB12 TABLE OF CONTENTS Safety Information .3 Basic Specifications .4 Detailed Specifications .5 Controls and their Function.6 Connections
2、 .7 Operation 10 Troubleshooting.11 Test Setup and Procedure .12 Service Bulletin JBL 2001-03 .13 Service Bulletin JBL 2001-04 .14 Service Bulletin JBL 2001-05 .17 Service Bulletin JBL 2001-07 .18 Service Bulletin JBL 2001-08 .19 Tech Tip JBLTT2003-04.20 Exploded View/Packaging.21 Amplifier Exploded
3、 View .22 Amplifier Faceplate/Access.23 Integrated Circuit Diagrams.24 Testing Procedures. 26 Block Diagram Revision 232 Electrical Parts List (PCB version 6.3 7.0) 33 Electrical Parts List (PCB version 7.2) .37 Electrical Parts List Revision 2.41 Printed Circuit Boards (PCB version 6.3).44 Printed
4、Circuit Boards (PCB version 6.4).47 Printed Circuit Boards (PCB version 7.2) .48 Schematics Version 1 Preamp (PCB version 6.3) .51 Power Amp (PCB version 6.0 -6.3). .52 Power Amp (PCB version 7.0) .53 Preamp (PCB version 7.2) .54 Power Amp (PCB version 7.2). .55 Schematics Version 2.56 PB12 DIFFEREN
5、CES IN REVISION 1 AND REVISION 2 REVISION 1 REVISION 2 Amplifier faceplate says “Made in Canada” Amplifier serial number starts with “AM” Black (or silver) potted, non-serviceable output module Amplifier serial number starts with “HA” Output transistors in the open, on a large black heatsink Large p
6、lastic cup enclosing the rear of the amp assembly Main PCB, bottom, solder-side contains all SMD devices “Made in Mexico” label on outer part of cabinet BOTH VERSIONS OF THESE AMPLIFIERS ARE NOT CONSIDERED INTERCHANGEABLE; THEY ARE NOT A DROP-IN REPLACEMENT IN THE CABINET OF THE OTHER VERSION. Radio
7、Fans.CN 收音机爱 好者资料库2PB123WarningAny person performing service of this unit will be exposedto hazardous voltages and the risk of electric shock. It isassumed that any person who removes the amplifier fromthis cabinet has been properly trained in protectingagainst avoidable injury and shock. Therefore,
8、 any serviceprocedures are to be performed by qualified servicepersonal ONLY!CautionBefore the amplifier is plugged in, be sure its ratedvoltage corresponds to the voltage of the AC powersource to be used. Incorrect voltage could cause damageto the amplifier when the AC power cord is plugged in. Don
9、ot exceed rated voltage by more than 10%: operationbelow 90% of rated voltage will cause poor performanceor may shut the unit off.Leakage/Resistance CheckBefore returning the unit to the customer, perform aleakage or resistance test as follows:Leakage Current. Connect the unit to its rated powersour
10、ce. Using an ammeter, measure the current betweenthe neutral side of the AC supply and chassis ground ofthe unit under test. If leakage current exceeds 0.5mA, theunit is defective. Reverse the polarity of the AC supplyand repeat.Resistance. Measure the resistance from either side of theline cord to
11、chassis ground, If it is less than 500k ohms,the unit is defective.WARNING! DO NOT return the unit to the customer if itfails one of these tests until the problem is located andcorrected.Critical ComponentsAll components identified with the IECsymbol in the parts list and schematicdiagram designate
12、components in whichsafety can be of special significance whenreplacing a component identified with. Useonly the replacement parts designated in the parts list orparts with the same rating of resistance, wattage or voltage.SAFETY INFORMATIONList of Safety Components Requiring Exact ReplacementsRevisi
13、on 1Revision 2DescriptionF1 - 80117093-105202-300Line Fuse Slo Blo 2.0A PWRCORD083-041802-009250V UL approved80105SPT-2 or better with polarized plug, UL approved wired with the hot side to fused side. Use with factory replacement panel strain relief (70305) only.TRX042-010053-003Power Transformer.
14、Use80116only factory replacement.BR RECTBR1Bridge diode. Use only50100052-400080-000factory replacement.C1,2C6,8Large electrolytic filter(2200uF 100V)(3300uf 80v)caps. Be sure 30710034-470745-200replacement part is at least the same working voltage and capacitance rating.Also the lead spacing is imp
15、ortant. Incorrect spacing may cause premature failure due to internal cabinet pressure and vibration.C10Does not apply4.7uF, 100 volt NPE low30718df radial. (On Power amp PCB)S64AMIDoes not applyPower output module.60302 Use only factory replacementFaceplaten/aUse only factory70325replacementRear Am
16、p Cover063-531808-000Use only factoryDoes not applyreplacementInductorDoes not applyCMC - Use only factory80100replacementInductorDoes not applyL1 - Use only factory80121replacementDoes not applyInductorL2 - Use only factory043-300101-000replacementDoes not applyInductorL3 - Use only factory043-7001
17、01-000replacementPB124Output Power250 watts RMSDriver12 WooferFrequency Response25Hz Low-Pass Frequency settingInputsLine Level (option: LFE); Speaker LevelOutputsSpeaker level fixed frequency 150HzLow-Pass FrequencyVariable from 50Hz 150HzHigh-Pass Frequency150Hz when using Speaker Level OutputDime
18、nsions (H x W x D)15 1/2 x 15 x 16394mm x 381mm x 406mm(with feet) 17 1/2 x 15 x 16445mm x 381mm x 406mmWeight40 lb/18.2kgRefinements may be made on occasion to existing products without notice but will always meet or exceed originalspecifications unless otherwise stated.PowerBass is a registered tr
19、ademark of JBL, Incorporated.00261-1BASIC SPECIFICATIONS PB12 SubwooferPB125JBL PB12 250W Powered Sub AmpLINE VOLTAGEYes/NoHi/Lo LineNom.UnitNotesUS 120vac/60HzYes108- 132120VrmsNormal OperationEU 230vac/50- 60HzYes207- 264230VrmsNormal operation, MOMS requiredParameterSpecificationUnitQA Test Limit
20、sConditionsNotesAmp SectionType (Class AB, D, other)Dn/an/aLoad Impedance (speaker)5.6Ohmsn/aNominalRated Output Power (120VAC)250Watts140Domestic version only 120 VAC- 60 HzRated Output Power (230VAC)250Watts130EU Version only 230 VAC- 50 HzTHD Rated Power0.3%122k filter145 WattsTHD 1 Watt0.1%0.522
21、k filterDC Offset10mV- DC20 Speaker OutputsDamping factor50DF35Measured at amplifier board At spkr cable. 150 Watts THD LP T 1M (NO LOAD)Resistance from V+ (C6 P+) to V- (C8 P-) gradually Fully CHARGED should read 10k Resistance from V+ (C6 P+) to S+ (SPK O/P) should read 1MResistance from V- (C8 P-
22、) to S+ (SPK O/P) should read 1M 2. Power UpLED RED With a 5mV signal to Low level input, LED should change to GREEN -Voltage measurements (DVM)OP AMPLEDP-U4(1)P-U4(7)RED0Vrms11.84VDCGREEN7.13Vrms-12.93VDC3. D.C. Operation -Voltage measurements (DVM) on CLASS D POWER AMPBetweenV+Q4(E)Q1(C)Q10(C)U7(1
23、)U7(2)U7(4)U7(6)U7(7)U7(8)And ThisPointGNDV-GNDGNDGNDGNDGNDGNDGNDGNDGet thisReading71.7V0V-71.7V0V-71.7V-71.5V-71.2V0V0V4.65V4. Check Switching Frequency Oscilloscope - USE THE PROBE TIP TO U6(7) TO GND Reading 100kHz +/-10%,24Vp-pB. Pre Amp SectionLine Level Input Sensitivity -Set upTurn level, XOV
24、ER FREQ POT Fully CW and LFE switch offGenerator Set at 200mV50HzSignal to Line level inputPB1230PB12 Testing Procedure (Cont.) (Revision 2 Only) - Voltage measurementsOP AMPU2(1)U2(14)U2(8)U3(7)U3(1)U3(14)U3(8)U5(7)U5(1)SPEAKERO/P306.9mV461mV460mV658mV628mV598mV2.326V2.02V3.57V23.33V2. High Level I
25、nput Sensitivity -Set upTurn level, XOVER FREQ POT Fully CW and LFE switch off Set Generator at 1.3V50HzSignal to High level input -Voltage measurements 15.3V at speaker output3. Low- Pass -Set upSet Generator at 200 mV100HzSignal to Line level inputMeasure voltage at S+ speaker output -Voltage meas