1、101 2 0 6SERVICE MANUALIMPORTANT NOTICEThis manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.It has been assumed that basic service procedures inherent to the industry, and more specifi cally YAMAHA Products, are already known and understood by the user
2、s, and have therefore not been restated.WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specifi ed. For these reasons, we advise all YAMAHA pr
3、oduct owners that any service required should be performed by an authorized YAMAHA Retailer or the appointed service representative.IMPORTANT: The presentation or sale of this manual to any individual or fi rm does not constitute authorization, certifi cation or recognition of any applicable technic
4、al capabilities, or establish a principle-agent relationship of any form.The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications
5、are, therefore, inevitable and specifi cations are subject to change without notice or obligation to retrofi t. Should any discrepancy appear to exist, please contact the distributors Service Division.WARNING: Static discharges can destroy expensive components. Discharge any static electricity your
6、body may have accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).IMPORTANT: Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. CONTENTSTO SERVICE PERSONNEL .2FRONT PANELS .34REAR
7、 PANELS .59REMOTE CONTROL PANELS .10SPECIFICATIONS . 1115INTERNAL VIEW .16SERVICE PRECAUTIONS .16DISASSEMBLY PROCEDURES .1719UPDATING FIRMWARE .2022SELF-DIAGNOSTIC FUNCTION .2346DISPLAY DATA .4748IC DATA .4960BLOCK DIAGRAM .61PRINTED CIRCUIT BOARDS .6275PIN CONNECTION DIAGRAMS .76SCHEMATIC DIAGRAMS
8、.7785REPLACEMENT PARTS LIST .8795REMOTE CONTROL .96100ADVANCED SETUP . 101102AV RECEIVER11.02RX-V371/HTR-3064When the following parts are replaced, the model name and the destination MUST be written to the back-up IC (EEPROM: IC222 on DIGITAL P.C.B.) to have proper operation. (See No. 22 SOFT SWITCH
9、 menu of the self-diagnostic function.) DIGITAL P.C.B. EEPROM: IC222 on DIGITAL P.C.B.P.O.Bo , Hamamatsu, apanRX-V371/HTR-3064Copyright 2011 All rights reserved.This manual is copyrighted by YAMAHA and may not be copied orredistributed either in print or electronically without permission.RadioFans.C
10、N 收音机爱 好者资料库This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive harm.DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON WHATSOEVER!Avoid prolonged, unprotected contact between solder and y
11、our skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor!If you come in contact with solder or components located inside the enclosure of this product, wash your hands before handling food.1. Critical Components InformationComponents having special characteristics are
12、 marked and must be replaced with parts having specifications equal to those originally installed.2. Leakage Current Measurement (For 120V Models Only)When service has been completed, it is imperative to verify that all exposed conductive surfaces are properly insulated from supply circuits. Meter i
13、mpedance should be equivalent to 1500 ohms shunted by 0.15 F.All of the P.C.B.s installed in this unit and solder joints are soldered using the lead free solder.Among some types of lead free solder currently available, it is recommended to use one of the following types for the repair work. Sn + Ag
14、+ Cu (tin + silver + copper) Sn + Cu (tin + copper) Sn + Zn + Bi (tin + zinc + bismuth)Caution:As the melting point temperature of the lead free solder is about 30C to 40C (50F to 70F) higher than that of the lead solder, be sure to use a soldering iron suitable to each solder. TO SERVICE PERSONNEL
15、Leakage current must not exceed 0.5mA. Be sure to test for leakage with the AC plug in both polarities.WARNING: CHEMICAL CONTENT NOTICE!About lead free solderFor U model“CAUTION”“F1501: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 6A, 125V FUSE.”For C modelCAUTIONF1501:
16、 REPLACE WITH SAME TYPE 6A, 125V FUSE.ATTENTIONF1501: UTILISER UN FUSIBLE DE RECHANGE DE MME TYPE DE 6A, 125V.WALLOUTLETEQUIPMENTUNDER TESTAC LEAKAGETESTER OREQUIVALENTINSULATINGTABLE2RX-V371/HTR-3064RX-V371/HTR-3064RadioFans.CN 收音机爱 好者资料库 FRONT PANELSTop viewFront viewRX-V371 (R, K, A, B, G, F, L,
17、S models)RX-V371 (U, C, T models)RX-V371 / HTR-30643RX-V371/HTR-3064RX-V371/HTR-3064HTR-3064 (U, C, T models)HTR-3064 (R, K, A, G, F, L, S models)4RX-V371/HTR-3064RX-V371/HTR-3064 REAR PANELSRX-V371 (U, C models)RX-V371 (R, S models)RX-V371 (T model)5RX-V371/HTR-3064RX-V371/HTR-3064RX-V371 (K model)
18、RX-V371 (A model)RX-V371 (B, G, F models)6RX-V371/HTR-3064RX-V371/HTR-3064RX-V371 (L model)HTR-3064 (U, C models)HTR-3064 (R, S models)7RX-V371/HTR-3064RX-V371/HTR-3064HTR-3064 (A model)HTR-3064 (T model)HTR-3064 (K model)8RX-V371/HTR-3064RX-V371/HTR-3064HTR-3064 (G, F models)HTR-3064 (L model)9RX-V
19、371/HTR-3064RX-V371/HTR-3064 REMOTE CONTROL PANELSRCU sheet(T model)RAV331(U, C, R, K, A, L, S models)RAV332(T model)RAV433(B, G, F models)10RX-V371/HTR-3064RX-V371/HTR-3064 SPECIFICATIONS Audio SectionRated Output Power (1 channel driven)(1 kHz, 0.9 % THD)U, C models (8 ohms)FRONT L/R .100 W/chCENT
20、ER .100 WSURROUND L/R .100 W/chR, T, K, A, B, G, F, L, S models (6 ohms)FRONT L/R .100 W/chCENTER .100 WSURROUND L/R .100 W/chRated Output Power (2 channel driven)(1 kHz, 0.9 % THD)U, C models (8 ohms)FRONT L/R .80 W + 80 WCENTER .80 WSURROUND L/R .80 W + 80 WMaximum Effective Output Power (1 channe
21、l driven, JEITA) (1 kHz, 10 % THD, 6 ohms)R, T, K, L, S modelsFRONT L/R .135 W/chCENTER .135 WSURROUND L/R .135 W/chDynamic Power Per Channel (IHF) (1 channel driven)U, C models8/6/4/2 ohms .110/130/160/180 WR, T, K, A, B, G, F, L, S models 6/4/2 ohms .105/130/150 WDynamic HeadroomU, C models (8 ohm
22、s) .0.23 dBInput Sensitivity/Input ImpedanceAV5, etc. . 200 mV / 47 k-ohmsMaximum Input Signal (1 kHz, 0.5 % THD, Effect on)AV5, etc. .2.3 VOutput Level/Output ImpedanceAUDIO OUT (REC) . 200 mV / 1.2 k-ohmsSUBWOOFER (2 ch STEREO and FRONT speaker: Small) . 1 V / 1.2 k-ohmsHeadphone Jack Rated Output
23、/ImpedanceAV5, etc. (1 kHz, 50 mV, 8 ohms) . 100 mV / 470 ohmsFrequency Response (10 Hz to 100 kHz)AV5, etc. to FRONT L/R .0 / -3.0 dBTotal Harmonic Distortion (1 kHz, 50 W)AV5, etc. (straight) to FRONT L/R speaker outU, C models(8 ohms) .0.06 % or lessR, T, K, A, B, G, F, L, S models(6 ohms) .0.06
24、% or lessSignal to Noise Ratio (IHF-A Network)AV5, etc. (STEREO) (Input shorted) to speaker out250 mV . 98 dB or moreResidual Noise (IHF-A Network)FRONT L/R speaker out .150 V or lessChannel SeparationAV5, etc. (Input 5.1 k-ohms shorted, 1 kHz / 10 kHz) . 60 dB or more / 45 dB or moreVolume Control
25、.MUTE / -80 dB to +16.5 dB / 0.5 dB stepTone Control Characteristics* FRONT L/R channel onlyBASSBoost/Cut . 10 dB / 2 dB step / 50 HzTurnover frequency .350 HzTREBLEBoost/Cut .10 dB / 2 dB step / 20 kHzTurnover frequency .3.5 kHzFilter CharacteristicsFRONT, CENTER, SURROUND (H.P.F.) .fc=40/60/80/90/