1、SR4023Please use this service manual with referring to the user guide ( D.F.U. ) without fail.ServiceManualSR4023SR4023 /N1B/U1BPart no. 90M03DW855010First Issue 2008.07MZReceiverTABLE OF CONTENTSSECTION PAGE 1. TECHNICAL SPECIFICATIONS . 1 2. POWER AMPLIFIER ADJUSTMENT . 2 3. SERVICE MODE . 3 4. UP
2、DATE MICROPROCESSOR SOFTWARE PROCEDURE . 4 5. WIRING DIAGRAM .15 6. BLOCK DIAGRAM .17 7. SCHEMATIC DIAGRAM .19 8. PARTS LOCATION .24 9. EXPLODED VIEW AND PARTS LIST . 33 10. MICROPROCESSOR AND IC DATA . 36 11. ELECTRICAL PARTS LIST . 44 12. ABOUT REPLACE THE MICROPROCESSOR WITH A NEW ONE . 62TUNING/
3、PRESETMEMORYST ANDBYPOWER ON/ST ANDBYMUTECLEART.MODEDIMMERF/PBANDS.DIRECTDOWNVOLUMEUPINPUTSELECTORRECEIVER SR4023PHONESDISPAUTOTUNEDSTSLEEPDIRECTSPKRB安全上注意:部品、安全上重要部品。必指定部品番号使用下。MARANTZ DESIGN AND SERVICEUsing superior design and selected high grade components, MARANTZ company has created the ultima
4、te in stereo sound.Only original MARANTZ parts can insure that your MARANTZ product will continue to perform to the specifications for which it is famous. Parts for your MARANTZ equipment are generally available to our National Marantz Subsidiary or Agent. ORDERING PARTS : Parts can be ordered eithe
5、r by mail or by Fax. In both cases, the correct part number has to be specified. The following information must be supplied to eliminate delays in processing your order : 1. Complete address 2. Complete part numbers and quantities required 3. Description of parts 4. Model number for which part is re
6、quired 5. Way of shipment 6. Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void.SHOCK, FIRE HAZARD SERVICE TEST : CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary A
7、C cord connector pins ( with unit NOT connected to AC mains and its Power switch ON ), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verified before
8、it is return to the user/customer. Ref. UL Standard No. 60065.In case of difficulties, do not hesitate to contact the Technical Department at above mentioned address. 080702MZUSAMARANTZ AMERICA, INC100 CORPORATE DRIVEMAHWAH, NEW JERSEY 07430USAEUROPE / TRADING D&M EUROPE B. V. P. O. BOX 8744, BUILDI
9、NG SILVERPOINTBEEMDSTRAAT 11, 5653 MA EINDHOVENTHE NETHERLANDSPHONE : +31 - 40 - 2507844FAX : +31 - 40 - 2507860KOREAD&M SALES AND MARKETING KOREA LTD.CHUNG JIN B/D., #1001,53-5, WONHYORO 3 GA, YONGSAN-GU,SEOUL, 140-719, KOREAPHONE : +82 - 2 - 323 - 2155FAX : +82 - 2 - 323 - 2154CANADAD&M Canada Inc
10、.5-505 APPLE CREEK BLVD. MARKHAM, ONTARIO L3R 5B1CANADAPHONE : 905 - 415 - 9292FAX : 905 - 475 - 4159JAPAND&M BUILDING, 2-1 NISSHIN-CHO,KAWASAKI-KU, KAWASAKI-SHI,KANAGAWA, 210-8569 JAPAND&M Holdings Inc.CHINAD&M SALES AND MARKETING SHANGHAI LTD.ROOM.808 SHANGHAI AIRPORT CITY TERMINAL NO.1600 NANJING
11、 (WEST) ROAD, SHANGHAI, CHINA. 200040TEL : 021 - 6248 - 5151FAX : 021 - 6248 - 4434NOTE ON SAFETY :Symbol Fire or electrical shock hazard. Only original parts should be used to replaced any part marked with symbol . Any other component substitution (other than original type), may increase risk of fi
12、re or electrical shock hazard.1TUNING/PRESETMEMORYST ANDBYPOWER ON/ST ANDBYMUTECLEART.MODEDIMMERF/PBANDS.DIRECTDOWNVOLUMEUPINPUTSELECTORRECEIVER SR4023PHONESDISPMULTIAUTOTUNEDSTV OFFNIGHTPEAKANALOGDIGITALATTSLEEPSURRAUTODIRECTDISC 6.1MTX 6.1SPKRBEQDIGITALSURROUNDPCMLCRSLSSRLFE15-5/16 in (388 mm)7/8
13、in(22 mm)3/4 in(17.5 mm)13-3/4 in (348.5 mm)9/16 in(14 mm)5-13/16 in(146.5 mm)17-5/16 in (440.0 mm)6-3/8 in(160.5 mm)FM TUNER SECTIONFrequency Range .87.5 - 108.0 MHzUsable Sensitivity .IHF 1.8 V/16.4 dBfSignal to Noise Ratio .Mono/Stereo 75/70 dBDistortion .Mono/Stereo 0.2/0.3 %Stereo Separation .1
14、 kHz 45 dBAlternate Channel Selectivity . 300 kHz 60 dB N . 400 kHz 60 dB UImage Rejection .98 MHz 70 dBTuner Output Level .1 kHz, 40 kHz Dev 500 mV NTuner Output Level .1 kHz, 75 kHz Dev 800 mV UAM TUNER SECTIONFrequency Range .531 - 1602 kHz N .520 - 1710 kHz U Signal to Noise Ratio . 50 dBUsable
15、Sensitivity . Loop 400 V/mDistortion . 400 Hz, 30 % Mod. 0.5 %Selectivity . 18 kHz 70 dB NSelectivity . 20 kHz 70 dB UAUDIO SECTIONRated Power (40 Hz - 20 kHz) 8 ohms .80 W / Ch 6 ohms .100 W / ChTHD (40 Hz - 20 kHz) .0.08%Input Sensitivity/Impedance Linear .200 mV/ 47 kohmsSignal to Noise Ratio (HI
16、F A) Linear . 95 dBGENERALPower Requirement .AC 230 V 50/60 Hz /N .AC 120 V 60 Hz /U Power Consumption .220 WWeight .9.0 kg ACCESSORIESRemote Control Unit RC002SR .1AAA-size batteries . 2FM Antenna .1AM Loop Antenna .1AC Power Cord .1User Guide .11. TECHNICAL SPECIFICATIONSDIMENSIONS22. POWER AMPLIF
17、IER ADJUSTMENTIdling Current Alignment1. Each of the measurement points are provided with the two test points. Set a digital Voltage meter to DC voltage input, connect the meter to the test points at both contact points.2. After the setup above, turn on the main switch.3. Adjust variable resistors (
18、VR51 - VR61) according to the digital voltmeter readings. The target setting value is the following table for each channels.Settings : Master Volume Minimum Speaker out No Load Top lid OPENTime Table of Idling Current RiseChannelAlignment PointMeasurement PointL chVR51CN51R chVR61CN61After Turning O
19、NAmbient temperature20 to 30 degrees centigradeMeasurement Voltage 10 min.5 mV 0.5 mV20 min.5 mV 0.5 mV30 min.5 mV 0.5 mV3V0806121NMonthDateRelease No. DestinationYearMZ XXXXXXXXX(XX is displayed in Hex)SERVICEMODESR40233. SERVICE MODEMicroprocessor (IC41) and FLD Segment Check Mode.Connect the main
20、s cord into the unit.1. Press the 2. POWER ON/STANDBY button for turn on the unit.Press the 3. DIMMER, MUTE and TUNING/PRESET UP buttons simultaneously more then 3 seconds.The FL display shows SERVICE MODE for 2 seconds then shows the model name. 4. Press the 5. S.DIRECT button, the software version
21、 of the MAIN CPU (IC41) is displayed in the format below. Press the 6. S.DIRECT button again, the serial Number of the unit is displayed. Press the 7. S.DIRECT button again, the left half, right half and center of the label area in the FLD light on and off each other.Press the 8. S.DIRECT button aga
22、in, the segments of the character area in the FLD flick in checker pattern.Press the 9. S.DIRECT button again to quit this mode.HOW TO RESET THE UNITShould the operation or display seem to be abnormal, reset the unit with the following procedure.The unit is turned on, press and hold the MUTE and S.D
23、IRECT buttons simultaneously for 3 seconds or more. Remember that the procedure will reset the settings of the TUNER PRESET etc., to their initial settings.44. UPDATE MICROPROCESSOR SOFTWARE PROCEDUREWhen microprocessor software was updated, update the software in the following procedure.Necessary E
24、quipment Windows PC (OS: Windows2000 or WindowsXP) with Serial port. RS-232C Dsub-9 pin cable (female to female/straight type). DATA UPDATE KIT (90M-SR4500JIG) Update tool (FlashProg.exe, other files and folders in Flash Programmer folder) Update data (SR4023_yymmdd-vv.h16)NOTE : The yy is two digit
25、s of year. The mm is month. The dd is date. The vv is release number. The update data is same as SR5023 and ST6003.A Update ProcedureCreate the MODEL NAME folder into anywhere on your 1. PCs hard disk. (Ex.: SR4023_SR5023_ST6003)Put the Flash Programmer and software folder into the 2. MODEL NAME fol
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Marantz-SR4023-avr-sm 维修电路原理图 Marantz SR4023 avr sm 维修 电路 原理图