Hitachi-HTADD1W-avr-sm 维修电路原理图.pdf
《Hitachi-HTADD1W-avr-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Hitachi-HTADD1W-avr-sm 维修电路原理图.pdf(31页珍藏版)》请在收音机爱好者资料库上搜索。
1、CAUTION:Before servicing this chassis, it is important that the service technician read the “Safety Precautions” and “Product Safety Notices” in this service manual.ATTENTION:Avant deffectuer lentretien du chassis, le technicien doit lire les Prcautions de scurit et les Notices de scurit du produit
2、prsents dans le prsent manuel.VORSICHT:Vor ffnen des Gehuses hat der Service-Ingenieur die Sicherheitshinweise“ und Hinweise zur Produktsicherheit“ in diesem Wartungshandbuch zu lesen.SERVICE MANUALMANUEL DENTRETIENWARTUNGSHANDBUCHData contained within this Service manual is subject to alteration fo
3、r improvement.Les donnes fournies dans le prsent manuel dentretien peuvent faire lobjet de modifications en vue de perfectionner le produit.Die in diesem Wartungshandbuch enthaltenen Spezifikationen knnen sich zwecks Verbesserungen ndern.September 2000AV SURROUND RECEIVERPARTS ARE SUBJECT TO CHANGE
4、FOR IMPROVEMENTCONTENTSSPECIFICATIONS.4SERVICE POINTS . .5ADJUSTMENTS .9WIRING DIAGRAM. .11PRINTED WIRING BOARD . .12CIRCUIT DIAGRAM.22BLOCK DIAGRAM . .28EXPLODED VIEW.29REPLACEMENT PARTS LIST . .30SM0102HTADD1EHTADD1EBSHTADD1WHTADD1WUNRadioFans.CN 收音机爱 好者资料库 ENGLISH SAFETY PRECAUTIONS WARNING: The
5、following precautions must be observed.ALL PRODUCTS Before any service is performed on the chassis an isolation transformer should be inserted between the power line and the product. 1. When replacing the chassis in the cabinet, ensure all the protective devices are put back in place. 2. When servic
6、e is required, observe the original lead dressing. Extra precaution should be taken to ensure correct lead dressing in any high voltage circuitry area. 3. Many electrical and mechanical parts in HITACHI products have special safety related characteristics. These characteristics are often not evident
7、 from visual inspection, nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified by marking with a ? on the schematics and the replacement
8、parts list. The use of a substitute replacement component that does not have the same safety characteristics as the HITACHI recommended replacement one, shown in the parts list, may create electrical shock, fire, X-radiation, or other hazards. 4. Always replace original spacers and maintain lead len
9、gths. Furthermore, where a short circuit has occurred, replace those components that indicate evidence of overheating. 5. Insulation resistance should not be less than 2M ohms at 500V DC between the main poles and any accessible metal parts. 6. No flashover or breakdown should occur during the diele
10、ctric strength test, applying 3kV AC or 4.25kV DC for two seconds between the main poles and accessible metal parts. 7. Before returning a serviced product to the customer, the service technician must thoroughly test the unit to be certain that it is completely safe to operate without danger of elec
11、trical shock. The service technician must make sure that no protective device built into the instrument by the manufacturer has become defective, or inadvertently damaged during servicing. CE MARK 1. HITACHI products may contain the CE mark on the rating plate indicating that the product contains pa
12、rts that have been specifically approved to provide electromagnetic compatibility to designated levels. 2. When replacing any part in this product, please use only the correct part itemised in the parts list to ensure this standard is maintained, and take care to replace lead dressing to its origina
13、l state, as this can have a bearing on the electromagnetic radiation/immunity. PICTURE TUBE 1. The line output stage can develop voltages in excess of 25kV; if the E.H.T. cap is required to be removed, discharge the anode to chassis via a high value resistor, prior to its removal from the picture tu
14、be. 2. High voltage should always be kept at the rated value of the chassis and no higher. Operating at higher voltages may cause a failure of the picture tube or high voltage supply, and also, under certain circumstances could produce X-radiation levels moderately in excess of design levels. The hi
15、gh voltage must not, under any circumstances, exceed 29kV on the chassis (except for projection Televisions). 3. The primary source of X-radiation in the product is the picture tube. The picture tube utilised for the above mentioned function in this chassis is specially constructed to limit X-radiat
16、ion. For continued X-radiation protection, replace tube with the same type as the original HITACHI approved type 4. Keep the picture tube away from the body while handling. Do not install, remove, or handle the picture tube in any manner unless shatterproof goggles are worn. People not so equipped s
17、hould be kept away while picture tubes are handled LASERS If the product contains a laser avoid direct exposure to the beam when the cover is open or when interlocks are defeated or have failed. RadioFans.CN 收音机爱 好者资料库WARNINGCheck that exposed parts are acceptably insulated from the supply circuit b
18、efore returning the repaired instrument to the customer.CHECKING METHODMeasure the resistance value between the both poles of attachment cup (power supply plug) and the exposed parts (parts such as covers etc. where the customer can easily touch) and check that the resistance value is 500k ohms or m
19、ore.SAFETY PRECAUTIONSThe following precautions should be observed when servicing.Since many parts in the unit have special safety related characteristics, always use genuine HITACHI replacement parts. Especially critical parts in the power circuit block should not be replaced with other makers. Cri
20、tical parts are marked with a ? in the circuit diagram and printed wiring board.Before returning a repaired unit to the customer, the service technician must thoroughly test the unit to ascertain that it is completely safe to operate without danger of electrical shock.SPECIFICATIONS Audio section Vi
21、deo section Tuner section General Remote control unit (RB-DD1S)(Power amplifier)Rated output:Front:60 W + 60 W(8W/ohms, 20 Hz 20 kHz with 0.08 % T.H.D.)Centre:60 W(8W/ohms, 20 Hz 20 kHz with 0.08 % T.H.D.)Surround:60 W + 60 W(8W/ohms, 20 Hz 20 kHz with 0.08 % T.H.D.)Output terminalsFront:A or B8 to
22、16W/ohmsA + B16W/ohms or moreCenter/Surround:8 to 16W/ohms(Analog)LINE input - PRE OUTInput sensitivity / input impedance:200 mV / 47 kW/kohmsFrequency response:10 Hz 50 kHz: +1, 3 dBS/N ratio:92 dB (IHF-A weighted)Total harmonic distortion:0.08 % (20 Hz 20 kHz)Rated output:1.2 VPHONO input-REC OUTI
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Hitachi-HTADD1W-avr-sm 维修电路原理图 Hitachi HTADD1W avr sm 维修 电路 原理图