HarmanKardon-AVR300-avr-sm维修电路原理图.pdf
《HarmanKardon-AVR300-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《HarmanKardon-AVR300-avr-sm维修电路原理图.pdf(91页珍藏版)》请在收音机爱好者资料库上搜索。
1、harman/kardon AVR300A/V DOLBY DIGITAL RECEIVERSERVICE MANUALCONTENTSSPECIFICATIONS.2ESD WARNING. .4LEAKAGE TESTING.5CONTROLS AND FUNCTIONS. .6SERVICE PROCEDURE.9ALIGNMENT PROCEDURE. .9IDLE CURRENT/DC OFFSET.10ALIGNMENT/TEST POINTS. 11CIRCUIT DESCRIPTION. 13BLOCK DIAGRAM 16BULLETIN HK2000-05. 17BULLE
2、TIN HK2000-02 Rev1.18DISASSEMBLY PROCEDURE.21UNIT EXPLODED VIEW.22MECHANICAL PARTS LIST.23PCB DRAWINGS25ELECTRICAL PARTS LIST.30INTEGRATED CIRCUIT DRAWINGS.52SCHEMATICS.80SEMICONDUCTOR PINOUTS.89WIRING DIAGRAM.90PACKAGE.91harman/kardon, Inc. 250 Crossways Park Dr. Woodbury, New York 11797Rev0 6/2002
3、RadioFans.CN 收音机爱 好者资料库RadioFans.CN 收音机爱 好者资料库Eachprecautioninthismanualshouldbefollowedduringservicing.Components identified with the IEC symbolin the parts list are special significance to safety. When replacing a component identified with, use only the replacement parts designated, or parts with
4、the same ratings or resistance, wattage, or voltage that are designated in theparts list in this manual. Leakage-current or resistance measurements must be made to determine that exposed parts are acceptablyinsulated from the supply circuit before retuming the product to the customer.Some semiconduc
5、tor (solid state) devices can be damaged easily by static electricity. Such components commonly are calledElectrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field effect transistors andsemiconductor chip components.The following techniques shoul
6、d be used to help reduce the incidence of component damage caused by static electricity.1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge onyour body by touching a known earth ground. Alternatively, obtain and wear a com
7、mercially available discharging wrist strap device,which should be removed for potential shock reasons prior to applying power to the unit under test.2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, toprevent electro
8、static charge build-up or exposure of the assembly.3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.4. Use only an anti-static solder removal device. Some solder removal devices not classified as anti-static can generate electrical chargessufficient to damage ES devices.5.
9、Do not use freon-propelled chemicals. These can generate electrical change sufficient to damage ES devices.6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most replacementES devices are packaged with leads electrically short
10、ed together by conductive foam, aluminum foil or comparable conductive material.)7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to thechassis or circuit assembly into which the device will be installed.Be sure no power
11、is applied to the chassis or circuit, and observe all other safety precautions.8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing togetheror your clothes fabric or the lifting of your foot from a carpeted floor can generate sta
12、tic electricity sufficient to damage an ES devices.CAUTION :- 4 -3001. lnspect all lead dress to make certain thatleads are not pinched or that hardware is notlodged between the chassis and other metalpartsintheunit.2. Be sure that any protective devices such asnonmetallic control knobs, insulating
13、fish-papers,cabinetbacks,adjustmentandcompartment covers or shields, isolationresistor-capacitynetworks,mechanicalinsulators, etc. Which were removed for theservicingareproperlyre-installed.Before returning the unit to the user, perform the following safety checks :3. Be sure that no shock hazard ex
14、ists ; check for leakagecurrentusingSimpsonModel229LeakageTester,standardequipment item No. 21641, RCA Model WT540A or usealternate method as follows : Plug the power cord directlyInto a 120 volt AC receptacle (do not use an IsolationTransformer for this test). Using two clip leads, connect a1500ohm
15、s,10wattResistorparalleledbya0.15uFcapacitor,inserieswithallexposedmetalcabinetpartsandaknownearthground,suchas a water pipe or conduit. Use a VTVM or VOM with 1000 ohms per volt, or higher sensitivity to measure the AC voltage drop across theresistor. (See diagram) Move the resistor connection to e
16、ach exposed metal part having a return path to the chassis (antenna, metal, beperformedwiththe0.35voltRMSormoreisexcessiveandindicatesapotentialshockhazardwhichmustbecorrectedbeforereturningtheunittotheowner.- 5 -300?SERVICE PROCEDURETEST EQUIPMENT REQUIRED1) AM/FM Signal generator2) Digital Multime
17、ter3) Distortion lever meter2. VFD segment illumination & textThis set do not have VFD segment check function because lack of u-com memory sizeSo For your checking VFD states according to each functionPlease refer to owners manual process.1. All ClearThis service program can clear all memorized oper
18、ations and functions.When the POWER ON, press the AM/FM button while pressing the PRO LOGICbutton.After this, Preset memory will be set to these frequencies.FMAMVERSION120230RDSVERSION120230RDSP187.587.50P9520522P288.088.00P10600594P390.090.00P11610999P495.095.00P1210001395P598.098.00P1314001611P699
19、.099.00P141500P7106.0106.00P151710P8108.0108.00ALIGNMENT PROCEDURES1. FM MONO. Distortion adjustmentstep12Input Signal SourceConnectionSignal generatoroutput to FMantennaterminal.(750hm)SignalFrequency98MHzSource Signal Output Level andModulation1000uV/m (60dBu)MONO 1kHz/Dev. 75kHzReceptionFrequency
20、98MHz(P5)AdjustmentPointT804T805AdjustmentValue0mV0.5mV(R831)DistortionlevelatTAPE-OUTMinimum4. FM STEREO Separation Adjustmentstep12Input Signal SourceConnectionSignal generatoroutput to FMantennaterminal.(750hm)SignalFrequency98MHzSource Signal Output Level andModulationsame specification asdistor
21、tion adjustment.Input only L channelFM STEREOsame specification asdistortion adjustment.Input only R channelFM STEREOReceptionFrequency98MHz(P5)98MHz(P5)AdjustmentPointVR803VR803AdjustmentValueOutput levelat TAPE-OUTchannel RMinimumOutput levelat TAPE-OUTchannel RMinimum2. FM MUTING LEVEL ADJUSTMENT
22、Turn variable resistor VR801 and stop at position TUNED is not shown (not indicated), then again turn the variable resistor VR801 to theopposite revolution and stop at a position TUNED is shown.step12Input Signal SourceConnectionSignal generatoroutput to FMantennaterminal.(750hm)SignalFrequency98MHz
23、Source Signal Output Level andModulation10uV/m (20dBu)MONO 1kHz/Dev. 75kHzReceptionFrequency98MHz(P5)AUTOSCANAdjustmentPointVR801Only confirmAdjustmentValueTUNEDindicate on VFDTUNEDindicate on VFD- 9 -2stepInput Signal SourceConnectionSignalFrequencySource Signal Output Level andModulationReceptionF
24、requencyAdjustmentPointAdjustmentValue11395kHz(230,230RDS)1400kHz(120)CT8015. AM-Tracking Adjustment (MW)Signal Generatoroutput to transmissionloop antenna(standard required loop)5mV/m(74dBu)400HzMOD.30%594kHz(230,230RDS)600kHz(120)594kHz(230,230RDS)600kHz(120)T801Output level(L or R)atTAPE-OUTMinim
25、umOutput level(L or R)atTAPE-OUTMinimum6. AM IF AdjustmentstepInput Signal SourceConnectionSignalFrequencySource Signal Output Level andModulationReceptionFrequencyAdjustmentPointAdjustmentValueT803Output level(L or R)atTAPE-OUTMaximumSignal Generatoroutput to transmissionloop antenna(standard requi