Denon-AVRX2000-avr-sm维修电路原理图.pdf
《Denon-AVRX2000-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Denon-AVRX2000-avr-sm维修电路原理图.pdf(198页珍藏版)》请在收音机爱好者资料库上搜索。
1、MODELJPE3E2EKEAE1E1KE1CAVR-E400PAVR-X2000PPPPINTEGRATED NETWORK AV RECEIVERVer. 4 Please use this service manual with referring to the operating instructions without fail. Some illustrations using in this service manual are slightly different from the actual set. For purposes of improvement, specifi
2、cations and design are subject to change without notice. Cautions when replacing the FRONT PANEL(Only AVR-X2000E3):Depending on when the model was manufactured, there may be washers in the FRONT PANEL screw positions. Washers are not used in the replacement FRONT PANEL.If you are replacing a FRONT P
3、ANEL that has washers, discard the washers.Please refer to the MODIFICATION NOTICE.eSERVICE MANUALeD&M Holdings Inc.RadioFans.CN 收音机爱 好者资料库ABOUT THIS MANUAL .3What you can do with this manual .3Using Adobe Reader (Windows version) .4SAFETY PRECAUTIONS .6NOTE FOR SCHEMATIC DIAGRAM .7NOTE FOR PARTS LI
4、ST .7TECHNICAL SPECIFICATIONS .9DIMENSION .10CAUTION IN SERVICING .11Initializing INTEGRATED NETWORK AV RECEIVER .11Service Jig .11DISASSEMBLY .121. FRONT PANEL ASSY .142. PCB MX PORT/PCB RS232C (AVR-X2000E3 only) .153. PCB HDMI .164. POWER TRANS MAIN .175. PCB VIDEO ASSY .176. PCB SMPS .187. RADIAT
5、OR ASSY .20SPECIAL MODE .22Special mode setting button (for E400E3 model) .22Special mode setting button (for X2000 model) .231. com/DSP Version display mode .242. PANEL/REMOTE LOCK Selection mode .283. Service Related Selection mode .29BLOCK DIAGRAM .324. Protection Pass mode .495. DM860A Reboot mo
6、de .496. Remote ID Setup mode .507. NETWORK Initialization mode .50JIG FOR SERVICING .52WHEN THE MICROPROCESSOR IS REPLACED WITH A NEW ONE .55PROCEDURE FOR UPGRADING THE VERSION OF THE FIRMWARE .551. How to update by DFW .552. How to update by DPMS .593. How to update by USB Memory .66ADJUSTMENT .74
7、TROUBLE SHOOTING .821. POWER .822. Analog video .833. HDMI/DVI .874. AUDIO .895. Network/USB .926. SMPS .95CLOCK FLOW & WAVE FORM IN DIGITAL BLOCK DIAGRAM .98LEVEL DIAGRAM .99BLOCK DIAGRAM .105POWER DIAGRAM .106WIRING DIAGRAM .107PRINTED WIRING BOARDS .108SCHEMATIC DIAGRAMS (1/24) .119FRONT UNIT (1/
8、1) .119INPUT UNIT (1/1) .120SMPS UNIT (1/1) .121VIDEO UNIT (1/3) .122VIDEO UNIT (2/3) .123VIDEO UNIT (3/3) .124AMP UNIT (1/2) .125AMP UNIT (2/2) .126MAIN UNIT (1/2).127MAIN UNIT (2/2).128HDMI UNIT (1/13) .129HDMI UNIT (2/13) .130HDMI UNIT (3/13) .131HDMI UNIT (4/13) .132HDMI UNIT (5/13) .133HDMI UNI
9、T (6/13) .134HDMI UNIT (7/13) .135HDMI UNIT (8/13) .136HDMI UNIT (9/13) .137HDMI UNIT (10/13) .138HDMI UNIT (10/13) .139HDMI UNIT (11/13) .140HDMI UNIT (12/13) .141HDMI UNIT (13/13) .142EXPLODED VIEW .143PARTS LIST OF EXPLODED VIEW .145PACKING VIEW .146PARTS LIST OF PACKING & ACCESSORIES .147SEMICON
10、DUCTORS .1481. ICs .1482. FL DISPLAY .170CONTENTS2RadioFans.CN 收音机爱 好者资料库Jump to the target of a schematic diagram connectorClick the Ref. No. of the target connector in the red box around a schematic diagram connector.The screen jumps to the target connector. Page magnification stays the same as be
11、fore the jump.CP401CP106vABOUT THIS MANUALRead the following information before using the service manual.What you can do with this manualSearch for a Ref. No. (phrase)(Ctrl+Shift+F)You can use the search function in Acrobat Reader to search for a Ref. No. in schematic diagrams, printed wiring board
12、diagrams, block diagrams, and parts lists.1.Press Ctrl+Shift+F on the keyboard. The Search window appears.2.Enter the Ref. No. you want to search for in the Search window, and then click the Search button.A list of search results appears.3.Click an item on the list. The screen jumps to the page for
13、that item, and the search phrase is displayed.CtrlShiftF3Using Adobe Reader (Windows version) PropertiesClick this button and check that the printer is set to a suitable paper size. PagetoprintSelect the following checkbox.More Options : Current View PageSizing&HandlingSelect the following checkbox.
14、Size / SizeOptions : FitAdd notes to this data (Sign)The Sign function lets you add notes to the data in this manual.Save the file once you have finished adding notes.Example using Adobe Reader XOn the View menu, click Sign. The Sign pane appears.Example using Adobe Reader 9On the Document menu, cli
15、ck Sign. Magnify schematic / printed wiring board diagrams - 1(Ctrl+Space, mouse operation)Press Ctrl+Space on the keyboard and drag the mouse to select the area you want to view. The selected area is magnified. When you want to move the area shown, hold down Space and drag the mouse. When you want
16、to show a full page view, press Ctrl+0 on the keyboard.CtrlSpace0PrintamagnifiedpartofthemanualThe Properties dialog box and functions will vary depending on your printer.1. Drag the mouse to magnify the part you want to print.2. On the File menu, click Print.3. Configure the following settings in t
17、he Print dialog box.4. Click the Print button to start printing.4Magnify schematic / printed wiring board diagrams - 2(Pan & Zoom function)The Pan & Zoom function lets you see which part of a magnified diagram is being shown in a separate window.Example using Adobe Reader XOn the View menu, point to
18、 Zoom, and then click Pan & Zoom. The Pan & Zoom window appears on the screen.Example using Adobe Reader 9On the Tools menu, point to Select & Zoom, and then click Pan & Zoom Window.Magnify schematic / printed wiring board diagrams - 3(Loupe Tool function)The Loupe Tool function lets you magnify a s
19、pecific part of a diagram in a separate window.Example using Adobe Reader XOn the View menu, point to Zoom, and then click Loupe Tool. The Loupe Tool window appears on the screen.Example using Adobe Reader 9On the Tools menu, point to Select & Zoom, and then click Loupe Tool Window.5SAFETY PRECAUTIO
20、NSThe following items should be checked for continued protection of the customer and the service technician.leakage current checkBefore returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds
21、 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable.CAUTIO
22、N Please heed the following cautions and instructions during servicing and inspection. Heed the cautions!Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling inst
23、ructions. Cautions concerning electric shock!(1) An AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while the set i
24、s energized, or by unplugging the power cord when replacing parts, for example.(2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly!Through great care is taken when parts were manufactured from sheet metal, there may b
25、e burrs on the edges of parts. The burrs could cause injury if fingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts!The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which have th
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Denon AVRX2000 avr sm 维修 电路 原理图