Denon-AVR2312CI-avr-sm维修电路原理图.pdf
《Denon-AVR2312CI-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Denon-AVR2312CI-avr-sm维修电路原理图.pdf(226页珍藏版)》请在收音机爱好者资料库上搜索。
1、D&M Holdings Inc.SERVICE MANUALeeMODELJPE3E2EKEAE1CE1KCIAVR-2312CIPAVR-2312PPPINTEGRATED NETWORK AV RECEIVERVer. 5S0376-0V05DM/DG1110 Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instruction
2、s without fail. For purposes of improvement, specifications and design are subject to change without notice.sssPlease refer to the MODIFICATION NOTICE.RadioFans.CN 收音机爱 好者资料库2CONTENTSSAFETY PRECAUTIONS .3NOTE FOR SCHEMATIC DIAGRAM .4TECHNICAL SPECIFICATIONS .5DIMENSION .5CAUTIONS IN SERVICING .6Init
3、ializing INTEGRATED NETWORK AV RECEIVER .6Service Jig .6DISASSEMBLY .71. FRONT PANEL ASSY .92. HEAT SINK ASSY .103. HDMI UNIT ASSY .124. TRANS MAIN .15SPECIAL MODE .16Special mode setting button .161. com/DSP Version display mode .172. Errors checking mode (Displaying the protection history) .203. R
4、emote ID Setup mode .22PROTECTION DIAGRAM .234. DIAGNOSTIC MODE (Video/Audio (signal) path confirmation mode) .24BLOCK DIAGRAM .29JIG FOR SERVICING .59WHEN THE MICROPROCESSOR IS REPLACED WITH A NEW ONE .63PROCEDURE FOR UPGRADING THE VERSION OF THE FIRMWARE .63ADJUSTMENT .70SURROUND MODES AND PARAMET
5、ERS .71TROUBLE SHOOTING .751. POWER .752. Analog video .763. HDMI/DVI .824. AUDIO .915. Network/USB .946. SMPS .97CLOCK FLOW & WAVE FORM IN DIGITAL BLOCK .100LAEVEL DIAGRAM .101PRINTED WIRING BOARDS .1077CH AMP (COMPONENT SIDE) .1077CH AMP (FOIL SIDE) .107SPMS (COMPONENT SIDE) .108SMPS (FOIL SIDE) .
6、108SPK_PREOUT (COMPONENT SIDE) .109SPK_PREOUT (FOIL SIDE) .110INPUT (COMPONENT SIDE) .111INPUT (FOIL SIDE) .112FUSE (COMPONENT SIDE).113RS232C_CNT (COMPONENT SIDE) .113FUSE (FOIL SIDE) .113RS232C_CNT (FOIL SIDE) .113POSISTOR (COMPONENT SIDE) .113POSISTOR (FOIL SIDE) .113FRONT (COMPONENT SIDE) .114V.
7、AUX (FOIL SIDE) .114FRONT (FOIL SIDE) .114V.AUX (COMPONENT SIDE) .114HDMI FFC (COMPONENT SIDE) .115GUIDE TOP (COMPONENT SIDE).115GUIDE L (COMPONENT SIDE) .115HDMI FFC (FOIL SIDE) .115GUIDE TOP (FOIL SIDE) .115GUIDE L (FOIL SIDE) .115USB (COMPONENT SIDE) .115HP (COMPONENT SIDE) .115GUIDE R (COMPONENT
8、 SIDE) .115USB (FOIL SIDE) .115HP (FOIL SIDE) .115GUIDE R (FOIL SIDE) .115SELECTOR (COMPONENT SIDE) .116RS232C (COMPONENT SIDE).116SELECTOR (FOIL SIDE) .116RS232C (FOIL SIDE) .116SIDE_CNT (COMPONENT SIDE) .117SIDE_CNT (FOIL SIDE) .117VIDEO (COMPONENT SIDE) .118VIDEO (FOIL SIDE) .119FRONT CNT (COMPON
9、ENT SIDE) .120FRONT CNT (FOIL SIDE) .121HDMI (COMPONENT SIDE) .122HDMI (FOIL SIDE) .123SCHEMATIC DIAGRAMS .124USB UNIT.124FRONT UNIT .124AMP UNIT (1/2) .125AMP UNIT (2/2) .126SPK/PREOUT/REG UNIT (1/4).127SPK/PREOUT/REG UNIT (2/4).128SPK/PREOUT/REG UNIT (3/4).129FRONT_CNT UNIT .130CNT/RS232C UNIT (1/
10、4).131CNT/RS232C UNIT (2/4).132CNT/RS232C UNIT (3/4).133CNT/RS232C UNIT (4/4).134INPUT UNIT .135VIDEO UNIT .136SMPS UNIT .137DIGITAL UNIT (1/16) .138DIGITAL UNIT (2/16) .139DIGITAL UNIT (3/16) .140DIGITAL UNIT (4/16) .141DIGITAL UNIT (5/16) .142DIGITAL UNIT (6/16) .143DIGITAL UNIT (7/16) .144DIGITAL
11、 UNIT (8/16) .145DIGITAL UNIT (9/16) .146DIGITAL UNIT (10/16) .147DIGITAL UNIT (11/16) .148DIGITAL UNIT (12/16) .149DIGITAL UNIT (13/16) .150DIGITAL UNIT (14/16) .151DIGITAL UNIT (15/16) .152DIGITAL UNIT (16/16) .153WIRING DIAGRAM .154EXPLODED VIEW .155PARTS LIST OF EXPLODED VIEW .157PACKING VIEW .1
12、60PARTS LIST OF PACKING & ACCESSORIES .160SEMICONDUCTORS .1621. ICs .1622. FL DISPLAY.193PARTS LIST OF P.C.B. UNIT .195PCB INPUT ASSY .195PCB FRONT ASSY .197PCB 7CH AMP ASSY .200PCB MAIN ASSY.207PCB CNT ASSY .211PCB VIDEO ASSY .213PCB HDMI ASSY .215PCB SMPS ASSY .224RadioFans.CN 收音机爱 好者资料库3SAFETY PR
13、ECAUTIONSThe following items should be checked for continued protection of the customer and the service technician.LEAKAGE CURRENT CHECKBefore returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current
14、exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable
15、.CAUTION Please heed the following cautions and instructions during servicing and inspection. Heed the cautions!Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handli
16、ng instructions. Cautions concerning electric shock!(1) An AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while th
17、e set is energized, or by unplugging the power cord when replacing parts, for example.(2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly!Through great care is taken when parts were manufactured from sheet metal, ther
18、e may be burrs on the edges of parts. The burrs could cause injury if fingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts!The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which
19、have the same properties for replacement. The burrs have the same properties. In particular, for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originall
20、y placed!For safety seasons, some parts use tapes, tubes or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and high voltage pa
21、rts, so be sure to set everything back as it was originally placed. Make a safety check after servicing!Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area around. Then ma
22、ke an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured.(Insulation check procedure)Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resista
23、nce tester, check that the insulation resistance value between the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired.Many of the electric and the structural parts used in
24、 the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and the use of replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety properti
25、es are indicated as shown below on the wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number.(1) Schematic diagrams .Indicated by the z mark.(2) Parts lists .Indicated by the z mark.The use of parts other than the desi
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Denon AVR2312CI avr sm 维修 电路 原理图