Denon-AVR1312XP-avr-sm维修电路原理图.pdf
《Denon-AVR1312XP-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Denon-AVR1312XP-avr-sm维修电路原理图.pdf(110页珍藏版)》请在收音机爱好者资料库上搜索。
1、START:|qzT7t3cIXfGvpSN6RPbAWw=|i4QKmwTsguF5/wkPVABzlM4GcWQGNoMv02uNeNz1Wog=|RtRIz5LbaS+BXuKmvA5tJg=|:ENDD&M Holdings Inc.SERVICE MANUALeeVer. 4 Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating i
2、nstructions without fail. For purposes of improvement, specifications and design are subject to change without notice.MODELJPE3E2EKEAE1E1K E1CAVR-1312PPPPAV SURROUND RECEIVERMODELJPE3E2EKEAE1E1K E1CDHT-1312XP sPP5.1CH HOME THEATER SYSTEMPlease refer to the MODIFICATION NOTICE.RadioFans.CN 收音机爱 好者资料库
3、2CONTENTSSAFETY PRECAUTIONS .3NOTE FOR SCHEMATIC DIAGRAM .4TECHNICAL SPECIFICATIONS .5DIMENSION .5CAUTIONS IN SERVICING .6Initializing AV SURROUND RECEIVER .6Service Jig .6DISASSEMBLY .71. FRONT PANEL ASSY .82. HDMI UNIT .93. INPUT UNIT .104. RADIATOR ASSY .115. POWER UNIT.126. POWER TRANS .12SPECIA
4、L MODE .13Special mode setting button .131. com/DSP Version display mode .14WHEN THE MICROPROCESSOR IS REPLACED WITH A NEW ONE .15PROCEDURE FOR UPGRADING THE VERSION OF THE FIRMWARE .151. Preparations .152. UPDATE FIRMWARE .163. Notice: .27Confirming the firmwares number after upgraded .27ADJUSTMENT
5、 .28Audio Section .28SURROUND MODES AND PARAMETERS .29TROUBLE SHOOTING .331. POWER .332. Analog video .343. HDMI/DVI .354. AUDIO .40CLOCK FLOW & WAVE FORM IN DIGITAL BLOCK .42BLOCK DIAGRAM .43LAEVEL DIAGRAM .47PRINTED WIRING BOARDS .49FRONT (COMPONENT SIDE) .49POWER (COMPONENT SIDE).49HEADPHONE (COM
6、PONENT SIDE) .49PORTABLE IN (COMPONENT SIDE) .49REGULATOR (COMPONENT SIDE) .49VOLUME (COMPONENT SIDE) .49VOLUME (FOIL SIDE) .50REGULATOR (FOIL SIDE).50FRONT (FOIL SIDE) .50PORTABLE IN (FOIL SIDE) .50HEADPHONE (FOIL SIDE) .50POWER (FOIL SIDE) .50MAIN (COMPONENT SIDE) .51INPUT (COMPONENT SIDE) .52INPU
7、T (FOIL SIDE) .53HDMI (COMPONENT SIDE) .54HDMI (FOIL SIDE) .54SCHEMATIC DIAGRAMS (1/7) .55FRONT UNIT .55POWER UNIT .55HEADPHONE UNIT .55PORTABLE UNIT .55PORTABLE UNIT(AVR-1312 ONLY) .55PORTABLE UNIT(AVR-1312 ONLY) .55iPOD/USB UNIT(AVR-1612 ONLY) .55SCHEMATIC DIAGRAMS (2/7) .56FRONT PART .56SCHEMATIC
8、 DIAGRAMS (3/7) .57INPUT & VOLUME UNIT .57SCHEMATIC DIAGRAMS (4/7) .58VIDEO UNIT .58SCHEMATIC DIAGRAMS (5/7) .59DSP UNIT .59SCHEMATIC DIAGRAMS (6/7) .60MCU UNIT .60SCHEMATIC DIAGRAMS (7/7) .61MAIN UNIT .61WIRING DIAGRAM .62EXPLODED VIEW .63PARTS LIST OF EXPLODED VIEW .64PACKING VIEW (for AVR-1312) .
9、67PARTS LIST OF PACKING & ACCESSORIES (for AVR-1312) .68PACKING VIEW (for DHT-1312XP) .69PARTS LIST OF PACKING & ACCESSORIES (for DHT-1312XP) .69SEMICONDUCTORS .701. ICs .702. FL DISPLAY.88PARTS LIST OF P.W.B. UNIT .90FRONT P.W.B. UNIT ASSY .90MAIN P.W.B. UNIT ASSY .93INPUT P.W.B. UNIT ASSY .97HDMI
10、P.W.B. UNIT ASSY .101SPEAKER SYSTEM PACK .103TECHNICAL SPECIFICATIONS .103DIMENSION .103SC-C1312 EXPLODED VIEW .104SC-C1312 PARTS LIST OF EXPLODED VIEW .104SC-F1312 EXPLODED VIEW .105SC-F1312(F) PARTS LIST OF EXPLODED VIEW .105SC-F1312(R) PARTS LIST OF EXPLODED VIEW .105DSW-1312 EXPLODED VIEW .106DS
11、W-1312 PARTS LIST OF EXPLODED VIEW .106SYS-1312 PACKING VIEW .107SYS-1312 PARTS LIST OF PACKING VIEW .108SCHEMATIC DIAGRAMS (1/1) .110RadioFans.CN 收音机爱 好者资料库3SAFETY PRECAUTIONSThe following items should be checked for continued protection of the customer and the service technician.LEAKAGE CURRENT CH
12、ECKBefore returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defectiv
13、e. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable.CAUTION Please heed the following cautions and instructions during servicing and inspection. Heed the cautions!Cautions which are de
14、licate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock!(1) An AC voltage is impressed on this set, so if you touch internal metal parts
15、when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while the set is energized, or by unplugging the power cord when replacing parts, for example.(2) There are high voltage parts inside. Handle
16、 with extra care when the set is energized. Caution concerning disassembly and assembly!Through great care is taken when parts were manufactured from sheet metal, there may be burrs on the edges of parts. The burrs could cause injury if fingers are moved across them in some rare cases. Wear gloves t
17、o protect your hands. Use only designated parts!The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which have the same properties for replacement. The burrs have the same properties. In particular, for the important safety parts that are
18、indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed!For safety seasons, some parts use tapes, tubes or other insulating materials, and some parts are mounted away from the surf
19、ace of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and high voltage parts, so be sure to set everything back as it was originally placed. Make a safety check after servicing!Check that all screws, parts
20、and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area around. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is
21、ensured.(Insulation check procedure)Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistance value between the inplug and the externally exposed metal parts (antenna terminal, h
22、eadphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired.Many of the electric and the structural parts used in the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and the use of replace
23、ment parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety properties are indicated as shown below on the wiring diagrams and the parts list in this service manual. Be sure to replace them with the pa
24、rts which have the designated part number.(1) Schematic diagrams .Indicated by the z mark.(2) Parts lists .Indicated by the z mark.The use of parts other than the designated parts could cause electric shocks, fires or other dangerous situations.CAUTION Concerning important safety parts4NOTE FOR SCHE
25、MATIC DIAGRAMWARNING:Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.CAUTION:Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the lea