Denon-AVR1612-avr-sm维修电路原理图.pdf
《Denon-AVR1612-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Denon-AVR1612-avr-sm维修电路原理图.pdf(146页珍藏版)》请在收音机爱好者资料库上搜索。
1、D&M Holdings Inc.SERVICE MANUALeeMODELJPE3E2EKEAE1E1KE1CAVR-1612PPPPAVR-1622PAV SURROUND RECEIVERVer. 1S0233-1V01DM/DG1104 Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without f
2、ail. For purposes of improvement, specifications and design are subject to change without notice.RadioFans.CN 收音机爱 好者资料库2CONTENTSSAFETY PRECAUTIONS .3NOTE FOR SCHEMATIC DIAGRAM .4TECHNICAL SPECIFICATIONS .5DIMENSION .5CAUTIONS IN SERVICING .6Initializing AV SURROUND RECEIVER .6Service Jig .6DISASSEM
3、BLY .71. HDMI UNIT ASSY .92. FRONT PANEL ASSY .103. INPUT PCB ASSY .114. RADIATOR ASSY .125. REGULATOR PCB .136. SMPS PCB .137. TRANS POWER .13SPECIAL MODE .14Special mode setting button .141. com/DSP Version display mode .152. Errors checking mode (Displaying the protection history) .173. Remote ID
4、 Setup mode .194. DIAGNOSTIC MODE (Video/Audio (signal) path confirmation mode) .21BLOCK DIAGRAM .23JIG FOR SERVICING .35WHEN THE MICROPROCESSOR IS REPLACED WITH A NEW ONE .37PROCEDURE FOR UPGRADING THE VERSION OF THE FIRMWARE .371. How to update by DFW .37ADJUSTMENT .41SURROUND MODES AND PARAMETERS
5、 .42TROUBLE SHOOTING .461. POWER .462. Analog video .473. HDMI/DVI .514. AUDIO .565. USB .596. SMPS .60WIRING DIAGRAM .64CLOCK FLOW & WAVE FORM IN DIGITAL BLOCK .65LEVEL DIAGRAM .66SCHEMATIC DIAGRAMS .71DIGITAL UNIT (1/8) .71 HDMI PART .71DIGITAL UNIT (2/8) .72 DIGITAL SUPPLY PART .72DIGITAL UNIT (2
6、/8) .72 HDMI PART .72DIGITAL UNIT (3/8) .73 MCU PART .73DIGITAL UNIT (4/8) .74 MCU_LEVEL_CHG PART .74DIGITAL UNIT (5/8) .75 USB TCC8600 PART.75DIGITAL UNIT (6/8) .76 DIR PART .76DIGITAL UNIT (7/8) .77 DSP PART .77DIGITAL UNIT (8/8) .78 MAIN DAC PART .78INPUT UNIT (1/2) .79 AUDIO PART .79INPUT UNIT (
7、2/2) .80 VIDEO PART .80FRONT UNIT .81VOLUME UNIT .81POWER UNIT .81HEADPHONE UNIT .81iPod/USB UNIT (AVR-1612 ONLY) .81PORTABLE UNIT (AVR-1312 ONLY) .81REGULATOR UNIT (AVR-1312 ONLY) .81MAIN UNIT .82REGULATOR UNIT .83D-TERMINAL UNIT(JP ONLY) .84CONNECTOR UNIT .85SMPS UNIT .86EXPLODED VIEW .87PARTS LIS
8、T OF EXPLODED VIEW .89PACKING VIEW .92PARTS LIST OF PACKING & ACCESSORIES .92PARTS LIST OF P.C.B. UNIT .94FRONT PCB UNIT ASSY .94DIGITAL PCB UNIT ASSY .96INPUT PCB UNIT ASSY .102MAIN PCB UNIT ASSY.104POWER PCB UNIT ASSY .108SEMICONDUCTORS .1101. ICs .1102. FL DISPLAY.135PRINTED WIRING BOARDS .137DIG
9、ITAL PCB UNIT .137FRONT PCB UNIT .139INPUT PCB UNIT .141MAIN PCB UNIT.143POWER PCB UNIT .145RadioFans.CN 收音机爱 好者资料库3SAFETY PRECAUTIONSThe following items should be checked for continued protection of the customer and the service technician.LEAKAGE CURRENT CHECKBefore returning the set to the custome
10、r, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current wit
11、h the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable.CAUTION Please heed the following cautions and instructions during servicing and inspection. Heed the cautions!Cautions which are delicate in particular for servicing are lab
12、eled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock!(1) An AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an
13、electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while the set is energized, or by unplugging the power cord when replacing parts, for example.(2) There are high voltage parts inside. Handle with extra care when the set is energized
14、. Caution concerning disassembly and assembly!Through great care is taken when parts were manufactured from sheet metal, there may be burrs on the edges of parts. The burrs could cause injury if fingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated
15、parts!The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which have the same properties for replacement. The burrs have the same properties. In particular, for the important safety parts that are indicated by the z mark on schematic diagr
16、ams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed!For safety seasons, some parts use tapes, tubes or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is als
17、o taken with the positions of the wires by arranging them and using clamps to keep them away from heating and high voltage parts, so be sure to set everything back as it was originally placed. Make a safety check after servicing!Check that all screws, parts and wires removed or disconnected when ser
18、vicing have been put back in their original positions, check that no serviced parts have deteriorate the area around. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured.(Insulation check procedure)Unplug
19、 the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistance value between the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.)
20、is 1M or greater. If it is less, the set must be inspected and repaired.Many of the electric and the structural parts used in the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and the use of replacement parts with higher ratings (rated powe
21、r and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety properties are indicated as shown below on the wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number.
22、(1) Schematic diagrams .Indicated by the z mark.(2) Parts lists .Indicated by the z mark.The use of parts other than the designated parts could cause electric shocks, fires or other dangerous situations.CAUTION Concerning important safety parts4NOTE FOR SCHEMATIC DIAGRAMWARNING:Parts indicated by th
23、e z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.CAUTION:Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if
24、the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective.WARNING:DO NOT return the set to the customer unless the problem is identified and remedied.NOTICE:ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHMALL CAPACITANCE VALUES ARE EXPRESSED
25、 IN MICRO FARAD, UNLESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO FARAD. EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.Parts indicated by nsp on this table cannot be supplied.When ordering a part, make a clear dist
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Denon AVR1612 avr sm 维修 电路 原理图