Crown-CE4000-pwr-sm维修电路原理图.pdf
《Crown-CE4000-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Crown-CE4000-pwr-sm维修电路原理图.pdf(140页珍藏版)》请在收音机爱好者资料库上搜索。
1、POWER AMPLIFIERSERVICE MANUAL130485-111/02Rev. B 2002 by Crown Audio, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone: 574-294-8000. Trademark Notice: Amcron and Crown are registered trademarks of Crown International. Other trademarks are the property of their respective owners.CE
2、Series CE 4000Some models may be exported under the name AmcronRadioFans.CN 收音机爱 好者资料库CE 4000 Service Manual II130485-1 Rev. B2002 Crown Audio, Inc. PRVENIR LE CHOC LECTRIQUE NENLEVEZ PAS LES COUVERTURES. RIEN DES PARTIES UTILES LINTRIEUR. DBRANCHER LA BORNE AVANT DOUVRIR LA MODULE EN ARRIRE.TO PREV
3、ENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSON-NEL. DISCONNECT POWER CORD BEFORE REMOVING REAR INPUT MODULE TO ACCESS GAIN SWITCH.CAUTIONAVISWARNINGTO REDUCE THE RISK OF ELECTRICSHOCK, DO NOT EXPOSE THISEQUIPMENT T
4、O RAIN OR MOISTURE!The information furnished in this manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance. If you need special assistance beyond the s
5、cope of this manual, please contact the Crown Technical Support Group.Mail: P.O. Box 1000 Elkhart IN 46515-1000Shipping: Crown Factory Service 1718 W. Mishawaka Road Elkhart IN 46517Phone: (800) 342-6939 / (574) 294-8200FAX: (574) 294-8301The lightning bolt tri-angle is used to alert the user to the
6、 risk of electric shock.The exclamation point trian-gle is used to alert the user to important operating or main-tenance instructions.RadioFans.CN 收音机爱 好者资料库 III CE 4000 Service Manual2002 Crown Audio, Inc.Revision HistoryRevision NumberDateCommentsRev. ARev. B05-200111-2002Initial PrintingAdded mis
7、sing parts list on Page 5-76. Updated area code and mailing address on Pages 1, 2 and 7. Updated sections 3.2.4, 4.3.3, 4.3.9, 4.4.5, 4.6.1, 4.6.8, 4.7.2, 4.7.3, Figure 4.16. Added notes to pages 5-39, 5-73, 5-97.130485-1 Rev. BCE 4000 Service Manual IV130485-1 Rev. B2002 Crown Audio, Inc.This page
8、intentionally left blank V130485-1 Rev. BCE 4000 Service Manual2002 Crown Audio, Inc.1 Introduction.1-1 1.1 Introduction.1-1 1.2 The CE 4000 Amplifi er.1-1 1.3 Scope.1-1 1.4 Warranty.1-12 Specifi cations.2-13 Theory of Operation .3-1 3.1 Audio Signal Path .3-1 3.1.1 Input Stage.3-1 3.1.2 Error Ampli
9、fi er.3-1 3.1.3 Modulator .3-1 3.1.4 Triangle Generator.3-2 3.1.5 Output.3-2 3.1.6 Output Filter.3-3 3.2 Protection and Control Circuitry.3-3 3.2.1 Current Monitor.3-3 3.2.2 Current Limiter.3-4 3.2.3 Display Circuitry.3-4 3.2.4 Control Circuitry.3-4 3.3 Power Supply Operation.3-5 3.3.1 Power Entry a
10、nd Filtering .3-5 3.3.2 Fuse.3-5 3.3.3 Low-Voltage Supplies (Flyback).3-5 3.3.4 Turn-On Control Circuitry.3-5 3.3.5 PFC Boost Stage.3-6 3.3.6 Bridge Isolation Stage.3-64 Maintenance.4-1 4.1 Where to Begin .4-1 4.2 Surface Mount Technology.4-1 4.3 Disassembly for Inspection & Service.4-1 4.3.1 Top Co
11、ver Removal.4-1 4.3.2 Power Supply Discharge.4-1 4.3.3 Flyback Supply PWA Removal.4-3 4.3.4 Input Module (SST) Removal.4-3 4.3.5 Output Panel Removal.4-3 4.3.6 Back Panel Assembly Removal.4-3 4.3.7 Line Filter PWA Removal .4-4 4.3.8 BFG PWA Removal.4-4 4.3.9 Main PWA Removal.4-4 4.4 Troubleshooting
12、.4-4 4.4.1 Troubleshooting Flyback Power Supply.4-4Table of ContentsCE 4000 Service Manual VI130485-1 Rev. B2002 Crown Audio, Inc. 4.4.2 Troubleshooting Trianglewave Generator and BCA Output Stage.4-5 4.4.3 Troubleshooting Power Supply, PFC PWA and Full Bridge DC to DC Converter.4-6 4.4.4 Identifyin
13、g Symptoms.4-6 4.4.5 Identifying and Repairing the Cause.4-7 4.5 Required Test Equipment.4-8 4.6 Electrical Checkout Procedures .4-9 4.6.1 Quiescent AC Power Draw.4-9 4.6.2 Gain Switches.4-9 4.6.3 Bridge Mono Operation.4-9 4.6.4 Frequency Response .4-9 4.6.5 Short Circuit Test .4-9 4.6.6 Output Powe
14、r.4-9 4.6.7 Intermodulation Distortion .4-9 4.6.8 Signal to Noise Ratio.4-9 4.6.9 Crosstalk at 20 kHz .4-10 4.6.10 Post Test Settings.4-10 4.7 Calibrations.4-10 4.7.1 Gaussian Filter Calibration.4-10 4.7.2 Overlap Correction and Adjustment.4-10 4.7.3 Current Sensing Calibration .4-11 4.7.4 Output Fi
15、lter Calibration .4-115 Parts.5-1 5.1 General Information.5-1 5.2 Ordering and Receiving Parts .5-1 5.2.1 Terms.5-1 5.2.2 Shipment .5-1 5.3 Mechanical Parts.5-1 5.3.1 CE4000 Amplifi er Assembly.5-2 5.3.2 Back Panel Assembly.5-4 5.3.3 CE4000 PS Primary Heatsink Assembly .5-5 5.3.4 CE4000 PS Diode Hea
16、tsink Assembly.5-6 5.3.5 CE4000 PS Output Heatsink Assembly.5-7 5.3.6 CE4000 Standard Input Assembly.5-8 5.3.7 CE4000 Standard Domestic Ouput Assembly.5-9 5.3.8 CE4000 Power Switch Assembly .5-10 5.4 Circuit Board Parts.5-11 5.4.1 Circuit Board and Schematic Part Numbers.5-116 Schematics.6-1Table of
17、 ContentsIntroduction 1-1130485-1 Rev. BCE 4000 Service Manual2002 Crown Audio, Inc.Crown Customer ServiceTechnical Support GroupFactory ServiceParts DepartmentMailing Address: P.O. Box 1000, Elkhart IN 46515Shipping Address: 1718 W. Mishawaka Rd., Elkhart IN 46517Phone: (574) 294-8200Toll Free: (80
18、0) 342-6939Fax: (574) 294-8301http:/1.1 IntroductionThis manual contains complete service information on the Crown CE 4000 power amplifi er. It is designed to be used in conjunction with the CE 4000 Reference Manual; however, some important information is duplicated in this Service Manual in case th
19、e CE 4000 Reference Manual is not readily available.NOTE: THE INFORMATION IN THIS MANUAL IS INTENDED FOR USE BY AN EXPERIENCED TECHNICIAN ONLY!1.2 The CE 4000 Amplifi erThe Crown CE 4000 is a compact audio amplifi er designed for professional use, providing high-power amplification from 20 Hz20 kHz
20、with minimum distortion. The CE 4000 features Crowns patented, award-winning BCA (Balanced Current Amplifi er) engineering, for superior power output, increased effi ciency, legendary Crown sound and extraordinary reliability. Crowns enhanced, switch-mode power supply with power factor correction al
21、lows the amplifier to be used worldwide without changing power supply components or settings. Other features include selectable on-board high-and low-pass fi lter sets, SST (System Solution Topologies) module compatibility, and a choice of dual output connectors: Speakon plus 5-way barrier block, 5-
22、way barrier block plus binding strip, or dual Speakon. 1.3 ScopeThis Service Manual in intended to apply to all versions of the CE 4000 amplifi er. The Parts Listings include parts specifi c for the US version and the European version. For parts specifi c only to other versions contact the Crown Tec
23、hnical Support Group for help in fi nding part numbers.1.4 WarrantyEach Reference Manual contains basic policies as related to the customer. In addition, it should be stated that this service documentation is meant to be used only by properly trained personnel. Because most Crown products carry a 3-
24、Year Full Warranty (including round trip shipping within the United States), all warranty service should be referred to the Crown Factory or Authorized Warranty Service Center. See the applicable Reference Manual for warranty details. To fi nd the location of the nearest Authorized Warranty Service
25、Center or to obtain instructions for receiving Crown Factory Service, please contact the Crown Technical Support Group (within North America), or your Crown/Amcron Importer (outside North America). If you are an Authorized Warranty Service Center and have ques-tions regarding the warranty of a produ