1、PRO-SVR_LEGACY Page 1 of 13 Date:July 17, 2007 Model Number: CA-301Class Audio Inc.Subject:Service manual Class Audio, Inc. 5070 Franois Cusson Lachine, Qubec Canada H8T1B3, RadioFans.CN 收音机爱 好者资料库PRO-SVR_LEGACY Page 2 of 13 Table of ContentsIntroduction 3Important Notes on Servicing 3Ordering Repla
2、cement Parts 3Block Diagrams 4Start up Procedure 5Protection Modes and Indicators 6Troubleshooting Guide 7Output Transistors Testing and Replacement 8Calibrations and Adjustments 9Parts List 10Updates 11Fuses 12Voltage Change 12IR Interface Information 13Schematics 14The contents of this document as
3、 well as the files associated with it contain confidential information that is proprietary to Class Audio Incorporated and are intended solely for the purpose of servicing product. No part of its contents may be used, copied, disclosed, or conveyed to any party in any manner whatsoever without prior
4、 written permission from Class Audio Incorporated. RadioFans.CN 收音机爱 好者资料库PRO-SVR_LEGACY Page 3 of 13 IntroductionPlease read this manual carefully before commencing servicing! Only qualified and authorized personnel should attempt to service this product. The lightning flash with arrowhead symbol,
5、within an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to aler
6、t the user to the presence of important operating and maintenance (servicing) instructions. Class has a global product support network. For product assistance or to order replacement parts please contact your nearest service center always quoting the unit serial number. North America Phone: (978) 66
7、4-2870 E-mail: EuropePhone: 44 (0) 1903 221 700 E-mail: AsiaPhone: (852) 2790 8903 E-mail: classebwgroup.hkRest of the World Phone: (514) 636-6384 E-mail: Important Notes on Servicing 1.ALWAYS observe ESD precautions when handling electronic modules or PCBAs. 2.NEVER exchange boards with a different
8、 revision number, unless authorized by Class. 3.ALWAYS use Class original replacement parts. The use of generic parts may void the warranty of the unit. Ordering Replacement Parts There may be a delay in processing incomplete requests. Please be sure to include all required information. Remember to
9、quote the serial number of the unit on all replacement part orders and the Class order number when returning defective parts for credit. PRO-SVR_LEGACY Page 4 of 13 Block diagramsPRO-SVR_LEGACY Page 5 of 13 Start Up ProcedureWhen receiving a unit, an assiduous visual inspection must be performed. Do
10、 not connect the unit without analysing the symptoms reported by the customer and the results of the inspection. Using the troubleshooting guide, find the problem and proceed to the repair. Once this step is done, follow these steps, known as the start-up procedure, to ensure that everything in the
11、unit is in working condition. 1. Proceed with a post repair visual inspection. Take the time to check if every wire is reconnected properly, every screw is bolted on, no soldering and/or metal residues lying in the unit, every fuse has been replaced, etc. 2. Connect the unit to a variable transforme
12、r, setted to 0Vac. 3. Turn the bias trimpot (RV1) counter clockwise until a click is heard. 4. Connect the bypass wire to the variable transformer. This bypass is a power cord, modified on the female side in order to bypass the soft start sequence. It is connected to the line tab on voltage selector
13、 PCB. 5. Slowly raise the voltage to 10Vac, and check positive and negative rails and pre-driver supply. Check fuses.6. If one or more supply are not within specifications, return to the troubleshooting guide. 7. Slowly raise voltage until you hear relays click, this point is around 55Vac. Recheck e
14、very supply. 8. If one or more supply are not within specifications, return to the troubleshooting guide. 9. Raise voltage to 120Vac. Recheck every supply 10. If every supply is within specifications, unplug the unit and bypass from the variable transformer. Reconnect only the unit. 11. Report to ca
15、libration and adjusments section to adjust bias and DC offset. Note that bias can be adjusted to 14mV, and the following tests can be performed before the unit is send to the burn-in bench for a 24 hours warm-up. 12. Connect the unit to a load, and to a source using balanced inputs and single ended
16、inputs, independently. 13. Perform a test with a 100Hz, a 1kHz and a 10kHz tone. Check the output with a oscilloscope, on 4 ohms and 8 ohms loads. Take special cares about oscillation and phase corelation between channels. 14. Connect the unit to a small speaker, and short the input. Check for any n
17、oise. Perform this step with single ended inputs and balanced inputs, independently. 15. Put the unit on a burn-in bench, and let it sit for 24 hours, then readjust bias. Let the unit on the burn-in bench for another 72 hours. 16. Redo steps 11 to 14 before shipping to the customer. PRO-SVR_LEGACY P
18、age 6 of 13 Protection Modes and IndicatorsThe front LED shows the status of the amplifier. When starting up normally, the CA301 will show a FLASHING RED LED for about 15 seconds and if all is normal, the LED will go SOLID RED. If there is a fault, the LED will go to a FLASHING GREEN LED. The CA301
19、is equipped with four Mosfet protection fuses. In the event that one or more of these fuses would blow, the technician will first need to identify and cure the cause of failure (please report to troubleshooting guide). When the cause has been identified, disconnect the unit from the system including
20、 the AC power. Remove the top cover and look for damaged or burned components. If no other components than the fuses appear to be damaged, the technician can then replace the broken fuses with the same value and rating (please report to fuses section). The Mosfet fuses are located on the control boa
21、rd. When replacing fuses, please make sure that the fuse holder are holding the fuses very tightly. A loose fuse holder can translate into distortion on top of the signal. PRO-SVR_LEGACY Page 7 of 13 Troubleshooting GuideSymptom Possible cause Unit won t turn on Check connections; Check fuses; Check
22、 soft-start circuit; Check relays; Check power supply circuits (positive rail, negative rail, Mosfet supply). Smoked and/or burned components Check for short between components and ground; Check output transistors; Check output relays; Check power supply circuits (positive rail, negative rail, Mosfe
23、t supply). Blown fuses Check for short between fuse and ground; Check power supply circuits (positive rail, negative rail, Mosfet supply). No output Check connexions; Check output relays; Check power supply circuits (positive rail, negative rail, Mosfet supply);Check output transistors. Unit turn in
24、to protection Check for smoked and/or burned components; Check power supply circuits (positive rail, negative rail, Mosfet supply);Check source and load; Check protection circuit; Check sensor wires between sensor PCB and control PCB; Check outputs transistors and Mosfet drivers. Excessive buzz and/