Bogen-MT125B-pa-sm维修电路原理图.pdf
《Bogen-MT125B-pa-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Bogen-MT125B-pa-sm维修电路原理图.pdf(6页珍藏版)》请在收音机爱好者资料库上搜索。
1、A DIVISION OF LEAR SIEGLER, INC.BOOSTER AMPLIFIERS MODELS MT-60A & MT-125BUNPACKING INPUT CONNECTIONSThe amplifier was thoroughly checked before leaving thefactory. Inspect the amplifier and shipping container carefullyfor evidence of improper handling during shipment. In case ofdamage, make an imme
2、diate claim to the dealer or distributorfrom whom the unit was purchased. If the amplifier was shippedto you, notify the carrier without delay and file a claim.Keep input leads away from the output leads and AC powercables. Unless the driving source provides a low-impedanceoutput, keep the input lea
3、d under ten feet in length. Refer to“Companion Units and Accessories” for Bogen preamplifierssuitable for use with the amplifier.TECHNICAL SPECIFICATIONSMT60A MT125BRATED OUTPUT POWER 60W 125WTOTAL HARMONIC DISTORTION Less than 2% at rated output 50 to 15,000 HzFREQUENCY RESPONSE 2 dB 20 to 20,000 H
4、zHUM & NOISE -85 dB below rated outputREGULATION Better than 2 dB no load to full loadINPUT SENSITIVITY 200mV for rated outputINPUT IMPEDANCE Hi-Z 50K ohm; Lo-Z 500/600 ohm with TL600 xfmr; Bridging input 1:1 with TL 100 xfmrCONTROLS AND INDICATORS Level control, illuminated power switch, speech fil
5、tersOUTPUT LOADS (Const. Volt.) 25V CT, 25V, 7OV, 11OVOUTPUT LOADS (Spkr. Imp.) 8 and 16 ohms 4, 8 and 16 ohms(See chart for other impedances) (See chart for other impedances)SEMICONDUCTORS 6 Transistors, 7 Diodes 10 Transistors, 6 DiodesPOWER CONSUMPTION I20VAC, 60Hz, 180 watts Rated 120VAC 60Hz, 3
6、60 watts Ratedoutput output120VAC 60Hz, 25 watts Quiescent 120VAC 60Hz, 45 watts Quiescent(no output) (no output)48-56 VDC, 3 Amp Rated 48-56 VDC, 6 Amps Ratedoutput output48-56 VDC, 350 mA Quiescent 48-56 VDC, 600 mA Quiescent(no output) (no output)AC Circuit BreakerOVERLOAD PROTECTION Thermal Circ
7、uit BreakerTransient Protection DiodesDIMENSIONS 3.1” x 8.5” x 14” (8 x 21.5 x 36 cm)WEIGHT 18% lbs. (8.40 kg.)5.25” x 8.5” x 15” (13 x 21.5 x 38 cm)27 lbs. (12.3 kg.)Printed in USA 8111 54469148RadioFans.CN 收音机爱 好者资料库COMPANION UNITS AND ACCESSORIESModelCAMCDMCSMCFC-1RPK-37TL100TL600Description and
8、InputsMixer-Preamplifier, 4 Hi-Z/Lo-Z Bal MIC, 1 AUXMixer-Preamplifier, 6 Lo-Z Bal MICStudio Mixer, 4 Lo-Z Bal MIC2/ 3 Octave EqualizerRack Mounting Kit 19” x 5” (48.26cm x 17.78cm; mounts 2 units)1: 1 Bridging Input TransformerLine Input Transformer, plug-in, 500/600-ohmimpedanceHigh impedance inpu
9、tThe amplifier can be driven to full output from any sourcedeveloping 200 mV across one of the Hi-Z inputs. Wire a single-conductor, low-capacity shielded input cable to a standardphono plug (Cinch 18A, or equivalent) and connect to one of theHi-Z jacks on the rear of the chassis. Amplifiers may als
10、o beconnected in parallel by connecting a patch cord from Hi-Zinput to Hi-Z input of the amplifiers without loss of gain.Low impedance inputThe amplifier will match a low-impedance (500/600 ohm)source if a Bogen Model TL-600 transformer is installed insocket Xl on the circuit board. Connect a twiste
11、d, shielded pair(Bogen BB-8450, or equiv.) input cable to the BAL INPUTLOW Z terminal strip on the rear of the unit. Use the twooutside terminals on the strip for input and connect the cableshield to the GND terminal. If an unbalanced input is required,connect a jumper from the GND terminal to an ad
12、jacent inputterminal.CA UTIONRemove all power from unittransformers.before installingOUTPUTTERMINALSTRIP OFDRIVERAMPLIFIERn74-0736-AAT 70V RI - IOK, WA T 25V RI = 3.3K,WFigure 1 -Input from another amplifierBalanced bridging inputThe inputs for two or more amplifiers may be paralleledwithout loss of
13、 gain. To do this, install a Bogen Model TLlOOtransformer in socket Xl. Connect the 6OOa source to the BALLOW Z terminal strip on the rear of the unit. Use the twooutside terminals on the strip and connect the cable shields tothe GND terminal. If an unbalanced input is required, connect ajumper from
14、 the GND terminal to an adjacent input terminal.Input from another amplifierThe amplifier can be driven from a standard public addressamplifier that provides a 25-volt or 70-volt constant voltageoutput. To do this, connect the output of the amplifier to one ofthe Hi-Z INPUT jacks via a resistor netw
15、ork (see figure 1). Theresistors shown in figure 1 are in addition to the normalloudspeaker load on the output of the public address amplifier.OUTPUTCONNECTIONSCA UTIONBe sure to foIlow 1ocaI electrical codes whenconnecting amplifier output.A variety of outputs is provided from the amplifier, either
16、balanced or unbalanced. Refer to Table 1 for appropriateconnections. Generally, the ground link does not need to beconnected unless an unbalanced output is especially desired.TABLE 1- Output Connections*110V 2607ov 83.350V 4245V -32.5V-31v 1625v 8to 10.5* 13v 2.812.5V 2.5*Unbalanced output only*Disc
17、onnect link between COM and GNDOUTPUTIMPEDANCE (ohms)VOLTAGE MT 60A MT 125B11254020168to 10-4 to 51.41.251 2 3 4 5 6 7*JUMPER1 to3OUTPUT2-7OUTPUT 3-7 5-7 36 4-6 3-6 3-5 l-2 342RadioFans.CN 收音机爱 好者资料库Figure 2 -External level control for amplifiers70V constant-voltage outputFor 70V constant voltage op
18、eration, connect the speakerleads to the 70V and COM terminals on the rear of the unit. Ifgrounding is required, connect the link from COM to GND.25V constant-voltage outputFor 25V constant-voltage unbalanced operation, connect thespeaker leads to 25V and COM, leaving the link connectedbetween COM a
19、nd GND. For balanced operation, open the linkbetween COM 1 and GND. If the output transformer center tapmust be grounded, connect a jumper between 25VCT and GND.CONNECTING AMPLIFIERS IN SERIESCAUTIONConnect only amplifiers of the same model inseries; do not mix different amplifier types.Bogen MTl25B
20、 or MT60A amplifiers may be connected inseries to increase total power output where absolutely necessaryto a single speaker line. Typical output connections are shown inTable 2. Note: GND straps on all except AMP I must be opened.Input connectionsIf the amplifier Hi-Z inputs are being driven directl
21、y, simplyparallel the amplifier Hi-Z inputs with a phono patch cord, andconnect the input line to one amplifier. When a balanced inputtransformer is being used, parallel the inputs at the screwterminals.Level control adjustmentIt is extremely important that the amplifiers have the samegain and produ
22、ce equal power output. This adjustment is mosteasily accomplished by setting both amplifier level controls tomaximum and then providing an external gain control as shownin figure 2. Make sure speech filter switches are in the sameposition. If an external control cannot be provided, amplifiergain mus
23、t be set with the use of an external tone source,adjusting the amplifiers to produce the same output with inputsparalleled. Always keep level controls at approximately thesame position even when setting up the amplifiers.CONNECTING AMPLIFIERS IN PARALLELIt is not recommended that amplifiers be conne
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Bogen MT125B pa sm 维修 电路 原理图