AustralianMonitor-AM1200-pwr-sm维修电路原理图.pdf
《AustralianMonitor-AM1200-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《AustralianMonitor-AM1200-pwr-sm维修电路原理图.pdf(58页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Australian Monitor 1 Clyde Street, Silverwater NSW 2128 Australia +61 2 9647 1411 .au SERVICE INFORMATION AM1200 POWER AMPLIFIER CONTENTS: OPERATION MANUAL SPECIFICATIONS COMPONENT & SUB ASSEMBLEY DISCRIPTIONS TEST PROCEDURE SCHEMATIC DIAGRAMS BOARD OVERLAYS PARTS LIST RadioFans.CN 收音机爱 好者资料库Operat
2、ionManualAM1200RadioFans.CN 收音机爱 好者资料库REFER SERVICING TOQUALIFIED PERSONNEL.NO USER SERVICEABLEPARTS INSIDE.!WARNING!DO NOT EXPOSE TO EITHERRAIN OR MOISTURE!CAUTION!RISK OF ELECTRICAL SHOCKDO NOT OPENThe user should not attempt to service the unit. Onlyqualified and knowledgeable personnel familiar
3、withthe internal workings of the unit should attempt anyrepair, servicing or authorized modification to theunit. The unit does not contain any parts which theuser can service or re-use in this or any other product.IMPORTANT!Please read carefully.This operation manual contains important information r
4、egardingsafety precautions, installation, performance, operation andmaintenance of your AM1200 power amplifier. You shouldfamiliarize yourself with the contents of thisSafety Precautionsand Labellingmanual before operating your amplifier.The rear panel of the unit has a number of markings andinterna
5、tionally recognized symbols related to thehazards and precautions that should be taken whenoperating MAINS connected equipment.The presence of a LIGHTNING FLASH with an arrowheadcontained within the boundaries of an equilateral triangleis intended to alert the user that dangerous uninsulatedvoltages
6、 may exist within the units enclosure. Thesevoltages may be of a sufficient magnitude as toconstitute the risk of an electrical shock.This symbol is reinforced with the text:The presence of an EXCLAMATION MARK containedwithin the boundaries of an equilateral triangle isintended to alert the user tha
7、t there is importantoperating and maintenance literature that accompaniesthe unit.The unit should not be operated in a situation where itmay encounter the entry of water, rain, or any fluids. Toexpose the unit to the above conditions may make theoperation of the unit hazardous and increase the risko
8、f electrical shock.If you are in need of special assistance and theinformation you require is outside the scope of thismanual, please contact your nearest service agent orAustralian Monitor direct:THE TECHNICAL OFFICERAUSTRALIAN MONITORC/- AUDIO TELEX COMMUNICATIONS PTY LTDPRIVATE BAG 149,SILVERWATE
9、R. N.S.W. 1811AUSTRALIA.PhoneFaxLocal(02) 9647-1411(02) 9748-2537International61-2-9647-141161-2-9748-2537E.auI.auFeatures:- 4, 3 or 2 channel operation.- Custom designed, 3RU heavy duty alloy chassis.- Modular construction.- Symmetrical layout - even weight distribution.- Linear, well-regulating, h
10、igh current power supply.- Dual isolated high current secondaries.- High efficiency toroidal mains transformer.- Continuous high power capability.- Lateral Mosfet Class AB output stage.- Binding post and Neutrik Speakon outputconnection.Protection Features- Suppression of inrush current at mains tur
11、n-on.- Input muting at turn-on.- Input overvoltage protection.- Radio-frequency interference suppression.- Thermal protection and indication.- Short-circuit protection and indication.- Input signal strapping (loop through) connectors.- Active balanced inputs.- 21 Position detented attenuators.- Mass
12、ive heat-sink / heat-exchangers.- Efficient front to back cooling.- Dual, twin speed axial fans.- Front and rear carry handles.- Front and rear mounting points.- High-quality, close-tolerance components used throughout.- Mains Circuit Breaker.- Independent DC supply rail fuses per channel.- Layout,
13、grounding, decoupling and componentryhave been optimized to provide the user withstability, reliability and longevity.ContentsPage1.Introduction52.Controls, Connectors and Indicators62.1 Front Panel72.2 Rear Panel93.Installation114.Operation135.Bridge Mode156.Two Ohm or Not Two Ohm167.Maintenance178
14、.Warranty189.Specification19List of IllustrationsPageFigure 1. Block Diagram5Figure 2. Front Panel Layout6Figure 3. Rear Panel Layout8Figure 4. Case Dimensions10Figure 5. Speakon Connector Wiring12Figure 6. Bridge Mode Speaker Wiring151. IntroductionCongratulations on choosing Australian Monitor for
15、your professional amplification requirements.The design of your AM1200 Audio Power Amplifierembraces all the aspects of a well designed unit. Thevisual design, mechanical, electrical and sonicparameters, along with our dedicated manufacturingprocess, have all been optimized to provide aprofessional
16、tool that exhibits quality, reliability andlongevity.The AM1200 amplifiers are 3 unit (5.25) tall, 19 wideFigure 1 Amplifier Block DiagramIntroduction 5rack mountable units.Each channel of the amplifier comprises a balancedactive input with an attenuator driving a differentialclass A drive stage whi
17、ch in turn drives a fan-cooled,class AB MOSFET output stage configured as asource follower. The unit operates from a high currentcapable linear power supply.These units have been specifically designed to delivertheir high power output with minimal distortion, andprovide the critical degree of contro
18、l required by yourspeakers, at high duty cycles for extended periods.6 Controls & ConnectorsFigure 2 Front Panel Layout2. Controls,Connectors& IndicatorsFront PanelFigure 1 shows the panel layout of the AM1200. Thefunctions of the controls and indicators are as follows:1. AttenuatorLevel control for
19、 your amplifier is provided by a 21position detented potentiometer and indicates gainreduction in decibels from the 0 dB position(maximum gain, no attenuation).2. Status IndicatorThis is a dual colour LED which displays the statusof the output stage and displays three levels ofoperation.These levels
20、 are:Below -20dB(unlit)-20dB and above(green)1dB below actual clipping(red)The LED will turn green once the output voltageexceeds the -20dB point (3.5 volts).The LED will change to red once the output ex-ceeds the -1dB point before actual clipping of theamplifiers output stage. The threshold of the
21、-1dBpoint is referred to the amplifier supply rails andalters with changes in the mains supply, changesin the load and duty cycle fluctuations.The attack and decay time (ballistics), of the statuscircuit are those of a Peak Programme Meter(P.P.M.)NOTE: The amplifier is not damaged by running intocli
22、pping, but speakers may be. To maximise the lifeof your speakers, try to keep clipping infrequent.3. Fault IndicatorThis amber LED will illuminate when a fault conditionexists.The fault detection circuit monitors the differencebetween drive and output in your amplifier.If you have a short on the spe
23、aker output (or a blownnegative rail fuse) the LED will flash brightly in syncwith the programme. This LED will also flash withprogramme peaks for gross overloads or if the loadis 2 ohms or less.The circuit has two stages of operation:1. It will provide indication (e.g. gross overload) butdoes not a
24、ffect the input signal (a faint flash).2. It will indicate and mute the input signal (e.g.shorted output) (brightly flashing or permanentlyon).4. Power SwitchPress the switch DOWN for power ON and UP forpower OFF. At start-up (turn-on) the input to theamplifier is muted by 30dB for approximately two
25、seconds.5. On / Thermal IndicatorWhen switching the amplifier on, this red LED willmomentarily flash Red, indicating correct operationof the Mains In-Rush Current Suppression circuit.After establishment of the Inrush CurrentSuppression circuit the LED will change to Greenindicating the unit is on an
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AustralianMonitor AM1200 pwr sm 维修 电路 原理图