AustralianMonitor-DCM250-pwr-sm维修电路原理图.pdf
《AustralianMonitor-DCM250-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《AustralianMonitor-DCM250-pwr-sm维修电路原理图.pdf(23页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Australian Monitor 1 Clyde Street, Silverwater NSW 2128 Australia +61 2 9647 1411 .au SERVICE INFORMATION DCM250 POWER AMPLIFIER CONTENTS: OPERATION MANUAL CIRCUIT DESCRIPTION SET-UP / TEST PROCEDURE SCHEMATIC DIAGRAMS PCB OVERLAYS COMPONENT LISTS RadioFans.CN 收音机爱 好者资料库DCM250250w Power AmplifierOp
2、erating ManualTEM PFAILON 24211815129630+3HIMAINSD C M 2 5 0RadioFans.CN 收音机爱 好者资料库Product DescriptionThe DCM250 is a 250 watt power amplifier designed for commercial installations. It can be used for either low impedance(4 ohm) or 100v line speaker systems. The amplifier can be mounted in a standar
3、d 19” equipment rack or it can be usedon a shelf or table. The DCM250 features a line level input (with parallel output) and is normally used with mixers, mixeramplifiers or other power amplifiers. The DCM250 will operate from 230/240 VAC 50 Hz (115 VAC 60 Hzwith factory modification) or 24 VDC and
4、will meet its full performance specification on either voltage supply. TheDCM250 also features a DC battery trickle charge facility, auto-sensing fan cooling, plus overload, short circuit andover temperature protection.DCM250, 250 Watt Power AmplifierFront Panel FeaturesPower SwitchThe rocker switch
5、 located in the front centre of the panel turns AC power on to the DCM250. Rocking the power switchto the right to turns the AC power on. When the AC power is on, a blue LED will glow. Please note that this switchdoes not switch DC voltage. If a DC voltage supply is connected to the DCM250, the ampl
6、ifier will operate as soonas the connection is made, regardless of the position of the AC power switch. If both an AC and DC voltage supply areconnected and you rock the AC power switch to the off position, the DCM250 will automatically continue tooperate normally from the DC supply (and the mains f
7、ailure LED will also glow under these conditions).Level ControlThe output level control is located in the centre of the front panel, just to the left of the mains rocker switch (re-cessed screwdriver adjustable pot). Turning the control clockwise will increase the output of the DCM250 towardsits max
8、imum output level while turning the control counter-clockwise will decrease the output level. Adjust thiscontrol for the desired output level depending on the level of the input signal (from a mixer or other signal source).The factory default setting for this control is such that a 1 volt input will
9、 give a 100 volt output.Amplifier Status DisplayThe amplifier status display highlights the operating condition of the DCM250.The status display indicates:High Temperature: This red LED glows if one of the fans has failed and the amplifier has been shut down by itstemperature control circuitry. If t
10、his LED is glowing and the fans have not failed, it means that the amplifier is operatingin an ambient environment that is too hot for fan cooling to make any difference to the temperature of the amplifier.Power: This LED glows blue if AC power is switched on to the DCM250. Note that this LED does n
11、ot indicate thepresence of a DC supply voltage.TEM PFAILON 24211815129630+3HIMAINSD C M 2 5 0Rear Panel FeaturesAC Power InletThe 3 pin IEC power inlet is located on the bottom left of the rear panel and accepts a standard mains power lead fittedwith an IEC connector. Before plugging in a power lead
12、, please check the rear panel of the amplifier to ensure that thevoltage label shows the correct AC operating voltage for your part of the world.The inlet is equipped with an in-built AC fuse holder fitted with a 6 Amp slow blow fuse plus a spare fuse. Please ensurethat the mains power cord is disco
13、nnected before attempting to check or replace this fuse. Power consumption is 400VA (max).Speaker Output Terminal StripLocated on the top left of the rear panel is the speaker output terminal strip. Reading from left to right, the connectionsare:COMCommon or “-” for low impedance speaker loads (4 oh
14、ms).4The “+” for 4 ohm speaker loads (use with common)COMCommon or “-” for 100v speaker loads (maximum load of 40 ohms at 100v)100The “+” for 100v line speaker loads (use with common)Please ensure that the correct “Common” is used. Low impedance and 100v loads can be used simultaneously but pleasepa
15、y careful attention to the overall speaker load. When used individually, the low impedance load should be 4 ohms orhigher while the 100v line load should not fall below 40 ohms. When both outputs are used simultanously, ensure thatneither output is loaded to maximum.24 Volt PowerLocated on the rear
16、panel are the red and black connection posts for 24v power. This feature can be used as either a back-up facility (if mains power fails) or for applications where AC power is not available. The left side red post is the +(positive) terminal while the right side black post is the - (negative) termina
17、l. The DC current drain is 15 Amps maximumat full power. This socket also provides trickle charge to a DC battery supply (if connected) when the DCM250 isoperated from AC mains power. The level of trickle charge is 300 mA, maximum.Mains Failure: The LED glows red if there is a failure in the AC main
18、s power supply. However, this LED will only glowif there is a DC supply voltage present. If no DC supply voltage is present then this LED will not glow.Output Level VU Meter: A 10 segment LED VU meter is provided to give an indication of the output signal level of theamplifier from -25 to +3 dB. Dur
19、ing normal operation, the LEDs will oscillate with changes in the program signal. Careshould be taken to avoid more than occasional illumination of the red LEDs. If the LEDs in the red zone are litcontinually, then the output level control (or the level of the input signal to the DCM250) should be a
20、djusted to reducethe output level. Too much output level can cause distortion, activate the internal limiter or possibly damage theconnected speaker system.230 VCC4100NCOHMAC FUSE 6A S/BDC FUSE2 X 10A S/B24 VDCINPUTENGINEERED BY AUDIO TELEX COMMUNICATIONS PTY LTD SYDNEY AUSTRALIAVOLTNC240 VTwin DC F
21、use ReceptaclesLocated on the rear panel are two DC fuse receptacles. Access each DC fuse by turning the cap counter-clockwisewith a screwdriver. The value of the fuse is 10 Amps slow blow. Please ensure that the AC power switch is in theoff position and that the mains power cord is disconnected bef
22、ore attempting to check or replace this fuseCooling Fan (Air Intake)The cooling fans are temperature sensitive and will only switch on when the temperature of the DCM250 had reached apre-determined range. The fan will stay on and only switch off again once the temperature of the DCM250 has fallenbel
23、ow a pre-determined level. If the DCM250 is operating continually at conservative levels and proper load conditions,it is possible that the cooling fan will not switch on at any time during normal operation. When operating, the fan workswith air flow from the front to the rear of the DCM250.Fuse Siz
24、esMains, 240 VAC : 6 Amperes Slow Blow.XLR Audio Input and Parallel OutputThe input to the DCM250 is transformer balanced 10K ohms. When signal is connected to one XLR, the otherXLR becomes a line level output allowing the input signal to be distributed (split) to other amplifiers. In someprojects,
25、the same input may be looped through to multiple amplifiers using this method. Up to 6 amplifiers can belooped together without any noticeable loss in level. A distribution amplifier should be used when more than 6amplifiers need to be looped.The XLRs are wired as follows: Pin 1: Shield. Pin 2: Hot,