Audiolab-8000S-int-sm维修电路原理图.pdf
《Audiolab-8000S-int-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Audiolab-8000S-int-sm维修电路原理图.pdf(36页珍藏版)》请在收音机爱好者资料库上搜索。
1、?RadioFans.CN 收音机爱 好者资料库introductionNo part of this document may be reproduced or transmitted in any form or by any means,electronic or mechanical, for any purpose, without the express written permission of International Audio Group Limited (IAG).This manual is for the exclusive use of IAG, its appr
2、oved distributors and approved UK service agents. No part of this manual shall be transferred to a third party without the written permission of IAG.It is the responsibility of the user to ensure that all the information contained in this manualis current. Notification for new issues of this manual
3、and minor updates will be given viathe IAG web-site or on request.This manual has been prepared with the greatest care, it is intended for information onlyand no liability shall be accepted for errors or changes to specification.For further service information, parts lists and updates, please contac
4、t our web-site. 2005 International Audio Group Limited. All rights reserved.Notification for new issues of this service manual will be given via the Audiolab web site:- issue number :- 2005/001/8000SG GR RP P0 00 00 00 03 3. .0011issue date :- September 04 20052 2 5 5 . . 0 0 1 1 . . 1 1 9 9 92 2 5
5、5 . . 0 0 1 1 . . 1 1 9 9 9 99999RadioFans.CN 收音机爱 好者资料库index1.0safety and servicing notes1.1Safety precautions.11.2Electrostatic discharge precautions .11.3Soldering.12.0front and rear panel layouts2.1Front panel controls .32.2Rear panel connections.33.0disassembly instructionsdisassembly instructi
6、onsPages 4 and 5 DELETED4.0functional tests4.1Test equipment required .64.2Functional test procedure.75.0performance tests5.1Test equipment required .115.2Performance test procedure .126.0test points6.1Functional and performance test points .167.0circuit schematics7.1Master schematic diagram (SCH267
7、M-01-05).177.2Line amplifier left channel schematic (SCH26701-07-02) .187.3 Line amplifier right channel schematic (SCH26701-08-02).197.4Power amplifier left channel schematic (SCH26701-09-02).207.5Power amplifier right channel schematic (SCH26701-10-02).217.6Power supplies schematic (SCH26701-01-02
8、) .227.7Protect and turn on schematic (SCH26701-06-02) .237.8Digital system controller schematic (SCH26701-02-01).247.9Digital system interface schematic (SCH26701-03-01).257.10Input interface schematic (SCH26701-04-04) .267.11Relay coils schematic (SCH26701-05-01) .277.12Front panel schematic (SCH2
9、6702-01-01) .287.13Speaker outputs schematic (SCH26703-01-01).298.0printed circuit board layout8.1Printed circuit board layout (top view).308.2 Printed circuit board layout (bottom view).319.0technical data9.1 8000S Technical specifications.329.2International standards.34 11.0 safety and servicing n
10、otes1.1Safety precautions1.This unit is Class II, which means that it is not connected to the protective earth system.All live voltages are insulated from the case by double insulation. 2.Do not attempt to service unless qualified to do so.3.Disconnect unit from AC power supply before removing cover
11、.4.Components marked with the symbol on the circuit schematic are safety critical and must only be replaced with an identical component, or an alternative approved bythe manufacturer.5.Switch unit off, and disconnect from supply before making and breaking anyconnections.6.Do not adjust any controls
12、unless instructed to do so in this manual.1.2Electrostatic discharge precautionsElectrostatic discharge (ESD) is due to charges produced by insulating materials rubbing together.Humans collect electrostatic charge through normal activities when clothes rub together and whenwalking on carpet. This ch
13、arge may be discharged suddenly when you touch a conductor. If theconductor is connected to a sensitive electronic circuit, you may damage the components. It is alsopossible to reduce the life of components without causing any obvious damage.To prevent ESD damage, it is necessary to follow these gui
14、delines.1.Prepare work area. Place an ESD protective mat on the bench, strapped to theprotective earth circuit.2.Prepare yourself. Put on an ESD protective wrist band, strapped to the protective earthcircuit, or to the ESD protective mat.3.Keep all PCBs removed from unit in ESD protective bags.4.Kee
15、p all replacement electronic components, PCBs and stock items in ESD protectivebags or boxes.5.Be particularly careful with components marked with the following symbol:1.3SolderingHow to de-solder componentsComponents should be removed, wherever possible, using a de-soldering tool. Be careful not to
16、damage tracks and pads by applying too much pressure.How to make good solder joints1.Ensure surfaces are clean.2.Keep soldering iron clean and wetted with solder. Use an appropriate bit. Do not leavesoldering iron on when not in use. 21.0 safety and servicing notes3.Apply soldering iron to both comp
17、onent lead and padbefore applying solder. Make sure that the solderingiron is applied long enough for the solder to wetproperly, but do not apply for too long or componentdamage may occur.4.Allow a small gap between component body andpad. Solder must not reach the base of thecomponent.How to detect
18、acceptable joints1.Solder joints should have from a shiny to satin lustreand a generally smooth appearance.2.Solder should have wetted both the component leadand pad.3.There should be a concave meniscus between theobjects being soldered. The angle of solder to padshould be less than 90 unless the so
19、lder joint extendsover the edge of the pad.4.Solder should fill the component pad and wetcomponent lead around the full circumference (360).How to detect unacceptable joints1.Poor wetting produces a bead of solder. The fillet willbe convex instead of concave, and there will not be afeather edge.2.On
20、 double-sided PCBs, solder should wet all roundplated-through hole, on both sides of the PCB.Cleaning up after soldering1.Flux is very corrosive. Remove with IPA (propan-2-ol) before completing the job. 2.Remove any solder balls and splashes from the unit.3.Check all new solder joints and ensure all
21、 PCBs are clean before replacing covers.4.After replacing covers, clean the case and any display windows with a damp cloth. Donot use any organic solvents. If scratched, replace display windows.Trim Line? ? ? ? ? ? 64.0 functional testsThese notes are provided to assist you in servicing the amplifie
22、r. The circuit schematics are markedwith typical voltage levels, which may assist in defining the cause of any problem.4.1Test equipment requiredEquipmentDigital MultimeterDual Tracking DC PowerSupplyVarious LeadsSpecificationAccuracy better than 0.5% in V and mV rangesOutput: 32 V DC 2 APositive te
23、rminal of negative supply must be connected tonegative terminal of the positive supply unless internally linkedVmAVmA-ve+ve-ve+veSelect Tracking0 V+32 V-32 VBlack= -veRed= +veGreen = 0 VFigure 4.1 - Functional test set-up 74.0 functional tests4.2Functional test procedureFor test point (TP) reference
24、s, see section 6.0 Test Points.No4.2.1.4.2.2.4.2.3.4.2.4.4.2.5.4.2.6.4.2.7.4.2.8.4.2.9.ActionDisconnect allcables fromamplifierCheck voltagesettingCheck fusetypeCheck fuseresistanceSet up powersupplyRemove coverConnectsupplies asshown inFigure 4.1Apply DCvoltage toamplifierMeasure leftchannel supply
25、railsTest EquipmentMultimeter set to Dual tracking DCpower supplyDual tracking DCpower supplyDual tracking DCpower supplyMultimeter set to V DCDetailsRead ratings label on rear of amplifier.Open fuse holder in power socket on rearpanel.Rated supplyFuse Type230 V AC T2.5A L250V115 V AC T4A 125V110 V