Fostex-PH100-pad-sm(1)维修电路原理图.pdf
《Fostex-PH100-pad-sm(1)维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Fostex-PH100-pad-sm(1)维修电路原理图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service ManualModelPH-100HEADPHONE AMP DISTRIBUTORRadioFans.CN 收音机爱 好者资料库SAFETY INSTRUCTIONSRead instructions - All the safety and operating instruc-tions should be read before the appliance is operated.Retain instructions - The safety and operating instructionsshould be retained for future referenc
2、e.Heed warnings - All warnings on the appliance and in theoperating instructions should be adhered to.Follow instructions - All operating and use instructionsshould be followed.Water and Moisture - The appliance should not be usednear water - for example, near a bathtub, washbowl,kitchen sink, laund
3、ry tub, in a wet basement, or near aswimming pool, and the like.Carts and Stands - The appliance should be used onlywith a cart or stand that is recommended by the manufac-turer.An appliance and cart combination should be moved withcare. Quick stops, excessive force, and uneven surfacesmay cause the
4、 appliance and cart combination to over-turn.Wall or Ceiling Mounting - The appliance should bemounted to a wall or ceiling only as recommended by themanufacturer.Ventilation - The appliance should be situated so that itslocation or position does not interfere with its proper ven-tilation. For examp
5、le, the appliance should not be situ-ated on a bed, sofa, rug, or similar surface that may blockthe ventilation openings; or, placed in a built- in installa-tion, such as a bookcase or cabinet that may impede theflow of air through the ventilation openings.Heat - The appliance should be situated awa
6、y from heatsources such as radiators, heat registers, stoves, or otherappliances (including amplifiers) that produce heat.Power Sources - The appliance should be connected to apower supply only of the type described in the operatinginstructions or as marked on the appliance.Grounding or Polarization
7、 - The precautions that shouldbe taken so that the grounding or polarization means ofan appliance is not defeated.Power Cord Protection - Power supply cords should berouted so that they are not likely to be walked on orpinched by items placed upon or against them, payingparticular attention to cords
8、 at plugs, convenience recep-tacles, and the point where they exit from the appliance.Cleaning - The appliance should be cleaned only as rec-ommended by the manufacturer.Nonuse Periods - The power cord of the appliance shouldbe unplugged from the outlet when left unused for a longperiod of time.Obje
9、ct and Liquid Entry - Care should be taken so thatobjects do not fall and liquids are not spilled into the en-closure through openings.Damage requiring Service - The appliance should be ser-viced by qualified service personnel when:A.B.C.D.E.Servicing - The user should not attempt to service the ap-
10、pliance beyond that described in the operating instruc-tions. All other servicing should be referred to qualifiedservice personnel.REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.CAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,DO NOT REMOVE COVER (OR BACK).NO USE
11、R- SERVICEABLE PARTS INSIDE.TO PREVENT ELECTRIC SHOCK, MATCHWIDE BLADE OF PLUG TO WIDE SLOT,FULLY INSERT.POUR VITER LES CHOCS LECTRIQUES,INTRODUIRE LA LAME LA PLUS LARGE DELA FICHE DANS LA BORNE CORRE-SPONDANTE DE LA PRISE ET POUSSERJUSQU AU FOND.CAUTION:ATTENTION:The exclamation point within an equ
12、ilateraltriangle is intended to alert the user to thepresence of important operating and mainte-nance (servicing) instructions in the litera-ture accompanying the appliance.The lightening flash with arrowhead symbol,within an equilateral triangle, is intended toalert the user to the presence of unin
13、sulated“dangerous voltage” within the productsenclosure that may be of sufficient magni-tude to constitute a risk of electric shock topersons.“WARNING”“TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS-TURE.”1.2.3.4.5.6.7.8.The power supply cord or the plug ha
14、s been damaged;orObjects have fallen, or liquid has been spilled into theappliance; orThe appliance has been exposed to rain; orThe appliance does not appear to operate normally orexhibits a marked changed in performance; orThe appliance has been dropped, or the enclosuredamaged.9.10.11.12.13.14.15.
15、16.17.RadioFans.CN 收音机爱 好者资料库3PH-100 Service ManualParts marked with this sign are safety critical components. They must always be replaced with identicalcomponents. Refer to the Fostex Parts List and ensure exact replacement.CAUTIONTABLE OF CONTENTSNOTES*Exploded view, PCB assembly, parts list and
16、circuit diagrams are given in this manual to assist the servicetechnician in maintaining the Model PH-100.*The following accessories are supplied with PH-100 as the standard accessories.PH-100 owners manual, MULTI: 8288495000*Following is the packing material for the Model PH-100.Carton, inner, PH-1
17、00: 8528031000Packing, side, A, PH-100: 8528029000Packing, side, B, PH-100: 85280300001.2.3.4.45614SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CONTROLS, INDICATORS & CONNECTORS . . . . . . . . . . . . . . . . . . . . . .
18、 . . . . . . . . . .EXPLODED VIEW, PCB ASSEMBLY & PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . .CIRCUIT & BLOCK DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4PH-100 Service Manual1. SPECIFICATIONSSPECIFICATION UNIT0 dBV = 1 V r.m.s., 0
19、 dBu = 0.775 V r.m.s.INPUTINPUT L/RConnectorXLR balanced, 6 mm balanced / unbalanced phone jackInput Level+ 4 dBu (XLR), - 10 dBVInput Impedance20 k or moreINPUT, AUX RTN L MONO / R, CH INConnectorRCA jackInput Level- 10 dBVInput Impedance20 k or moreOUTPUTPHONESConnector6 mm stereo phone jackMaximu
20、m Output Level500 mW (32 )Load Impedance8 32 CASCADE OUT L/RConnectorRCA jackOutput Level-10 dBVLoad Impedance10 k or moreOUTPUT49 (H) x 484 (W) x 267 (D) mmWEIGHTAbout 4 kgPOWERJPNAC 100 V 50 / 60 HzUSA /CND (UL)AC 120 V 60 HzEUR (IEC CLASS I)AC 230 V 50 / 60 HzUK (BS)AC 230 V 50 HzPOWER CONSUMPTIO
21、N18 WSTANDARD ENVIRONMENTStandard Temperature20 3 CStandard Humidity60 5 %ENVIRONMENT CONDITIONCharacteristics GuaranteedTemperature+ 5 + 35 CHumidity30 % 65 %AC Voltage Deviation 5 % or lessOperation GuaranteedTemperature- 5 + 45 CHumidity10 % 90 %AC Voltage Deviation 5 % or lessPHONES MAXIMUM OUTP
22、UT500 mW (at 32 load, 3 % distortion, -10 dBV / 1 kHz input)DISTORTIONPHONES- 65 dBV or less (DIN AUDIO), - 80 dBV or less (IHF A)CASCADE OUT- 85 dBV or less (DIN AUDIO), - 90 dBV or less (IHF A)RESIDUAL NOISEPHONES0.1 % or less (200 mW, 32 , 1 kHz)CASCADE OUT0.05 % or less (-10 dBV, 1 kHz)FREQUENCY
23、 RESPONSEPHONES30 Hz 20 kHz: 2 dB (200 mW, 32 )CASCADE OUT30 Hz 20 kHz: 1 dBCLICK NOISE- 20 dBVp-p or less (CASCADE OUT)Specifications and physical appearance are subject to change without notice for product improvement.5PH-100 Service Manual2. CONTROLS, INDICATORS & CONNECTORS1.PHONES level control
24、s (1 through 10)2.PEAK indicator3.AUX IN level control4.POWER switch / indicator5.INPUT level control6.INPUT (ST, MONO) select switch7.PHONES jacks (1 through 10)100HEADPHONE AMP DISTRIBUTORPOWER100PH-10055AUX ININPUTMONOST1005100510051005100510051005100510051005PEAK10987654321PHONESCAL1234567+4dBu5
25、4321109876PHONES (PRIORITY TO FRONT PHONES OUTPUT)AC INCASCADEOUT (-10dBV)L109876RL/MONOINPUT(-10dBV)CHANNEL IN (-10dBV)INPUT LINPUT R-10dBV-10dBVHOTRL/MONOAUX IN(-10dBV)COLDGNDXLRPHONE231TRS21435R+4dBu21345 6781.AC IN connector2.PHONES jacks (1 through 10)3.CASCADE OUT jacks (L, R) (RCA: -10 dBV)4.
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Fostex PH100 pad sm 维修 电路 原理图