Bose-1800V-pwr-sup1维修电路原理图.pdf
《Bose-1800V-pwr-sup1维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Bose-1800V-pwr-sup1维修电路原理图.pdf(5页珍藏版)》请在收音机爱好者资料库上搜索。
1、1CAUTION: THE 1800-V PROFESSIONAL STEREO POWERAMPLIFIER SYSTEM CONTAINS NO USER-SERVICEABLE PARTS.TO PREVENT WARRANTY INFRACTIONS, REFER SERVICING TOWARRANTY SERVICE STATIONS OR FACTORY SERVICE.PROPRIETARY INFORMATIONTHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OFBOSE CORPORATION WHICH IS BEING FU
2、RNISHED ONLY FORTHE PURPOSE OF SERVICING THE IDENTIFIED BOSE PRODUCTBY AN AUTHORIZED BOSE SERVICE CENTER OR OWNER OF THEBOSE PRODUCT, AND SHALL NOT BE REPRODUCED OR USEDFOR ANY OTHER PURPOSE.Table of ContentsSAFETY INFORMATION. 2SUPPLEMENT OVERVIEW AND PROCEDURES . 3Figure 1. 1800-V Amplifier PCB. 4
3、Figure 2. 1800-V Power Supply PCB . 4Figure 3. 1800-V Regulator PCB . 4RadioFans.CN 收音机爱 好者资料库21. Parts that have special safety characteristics are identified by the symbol onschematics or by special notes on the parts list. Use only replacement parts that havecritical characteristics recommended b
4、y the manufacturer.2. Make leakage current or resistance measurements to determine that exposed partsare acceptably insulated from the supply circuit before returning the unit to thecustomer. Use the following checks to perform these measurements:A. Leakage Current Hot Check-With the unit completely
5、 reassembled, plug the ACline cord directly into a 120V AC outlet. (Do not use an isolation transformer duringthis test.) Use a leakage current tester or a metering system that complies withAmerican National Standards Institute (ANSI) C101.1 Leakage Current for Appli-ances and Underwriters Laborator
6、ies (UL) 1492 (71). With the unit AC switch first inthe ON position and then in OFF position, measure from a known earth ground(metal waterpipe, conduit, etc.) to all exposed metal parts of the unit (antennas,handle bracket, metal cabinet, screwheads, metallic overlays, control shafts, etc.),especia
7、lly any exposed metal parts that offer an electrical return path to the chassis.Any current measured must not exceed 0.5 milliamp. Reverse the unit power cordplug in the outlet and repeat test. ANY MEASUREMENTS NOT WITHIN THE LIM-ITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUSTBE ELI
8、MINATED BEFORE RETURNING THE UNIT TO THE CUSTOMER.B. Insulation Resistance Test Cold Check-(1) Unplug the power supply and con-nect a jumper wire between the two prongs of the plug. (2) Turn on the power switchof the unit. (3) Measure the resistance with an ohmmeter between the jumpered ACplug and e