BO-HDR1_type464x-sm维修电路原理图.pdf
《BO-HDR1_type464x-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《BO-HDR1_type464x-sm维修电路原理图.pdf(38页珍藏版)》请在收音机爱好者资料库上搜索。
1、HDR 1 Type 4640, 4641, 4642Service Manual EnglishGerman, French, Italian, Spanish, Danish and Dutch versions are available in the Retail SystemThis Service Manual must be returned with the defective parts/back-up suitcase !RadioFans.CN 收音机爱 好者资料库CONTENTSSurvey of modules . 1.1How to service . 1.2Fau
2、lt flow chart . 2Adjustments and configuration . 3.1Final check after repair . 3.3Service menu . 3.5Service mode . 3.6Codec menu . 3.9ServiceTool . 3.11Remove cover . 4.1Replacement of modules . 4.2 - 4.5Specification guidelines for service use . 5.1Type survey . 5.2Wiring diagram . 6Available parts
3、 . 7RadioFans.CN 收音机爱 好者资料库Power supply boardA/V boardDisplay boardFANMAINSSCARTTuner213DATA(Mini jack)P7P4P1110TU 1+2P3P13Y/C InputP2P12P1P2P1P5P8HD unit complete998HD Drive4Codec board5P13NTCP10HD powerProcessorboard67PCB1 Power supply boardPCB2 A/V boardPCB3 Display boardPCB7 NTC998Module HD unit
4、 complete, incl. PCB4, PCB5, PCB7Survey of modules 1.1How to serviceStrategyThe HDR 1 is to be serviced in the customers home.The static-protective fi eld service kit must always be used when the product is disassembled or modules are being handled.The repair involves replacement of the HD unit, mod
5、ule(s) or fan.The replaced modules must be returned for repair at Bang & Olufsen, Module Repair Department.Fault description and error codes must be returned with the replaced parts.Use the Module Repair form or the form in the Retail Order System, Exchange Module.The EEPROM 6IC6 must be transferred
6、 to the A/V board in the HDR 1, hereby maintaining the customer settings.The ServiceTool is required in several service situations, e.g. update of SW.Refer to the ServiceTool for full description of features and operation.Preparations before serviceAlways remember to download the latest version of t
7、he Service Manual.Fault description and error codes must be returned with the replaced parts.Use the Module Repair form or the form in the Retail Order System, Exchange Module.Fault explanation and demonstrationBefore troubleshooting is initiated, let the customer demonstrate the fault, if possible.
8、Error codeThe error code contains data that may be used for repairing the module(s) and must be returned with the module(s).Handling the error code1. Take a note of the error code, for example on the Module repair form.2. Use the error code when troubleshooting.3. Return the error code, either on th
9、e Module Repair form or in the Retail system.4. Before returning the HDR 1 to the customer, clear the error code.Recommended tools for serviceB&O ServiceTool.White gloves.Soft lint-free cloth.IC-pliers. (Part no. 3629145).1.2 How to serviceHandling and cleaningStatic electricityStatic electricity ma
10、y damage the product.Static-protective fi eld service kit.A static-protective fi eld service kit must always be used when the product is disassembled or modules are being handled.Follow the instructions in the guide and use the ESD-mat for both old and new modules.Please note:When mains voltage on t
11、he product is required, remove the connection between the product and the ESD-mat.The chassis or modules must always be connected to the static-protective fi eld service kit or placed in an ESD-proof bag.Symbol of safety componentsWhen replacing components with this symbol, the same type has to be u
12、sed, also the same values for ohm and watt. The new component is to be mounted in the same way as the replaced one.Lithium batteryWARNINGShort-circuit and overcharging of some types of lithium batteries may result in a violent explosion.Transport and handlingIt is recommended to: - use the product c
13、over when transporting the product.- do not move the HDR 1 when it is operating.CleaningPlease refer to the chapter “Final check after repair” or the Users guides.STATIC ELECTRICITYMAY DESTROY THEPRODUCTESDHow to service 1.31.4Fault fl ow chart 2.1 HD unitDisplaySplitterTunerIF +DEMODSwitchVideoproc
14、essorEncoderY/CA/V BoardBeoVisionPower supply5V SB+12V+40V+8V-8V+3.3V+5V32V40V2.5V3.3VCVBSCVBSRGB+5VStandbyTimerRecordAnt outRGBY/CScartAnt inPower supply boardA/V BoardDisplay boardFANMAINSSCARTTuner020103DATA(Mini jack)P7P4P11P10TU 1+2P3P13Y/C InputP2P12P1P2P1P5P8HD unit complete998HD Drive04Codec
15、 board05P13NTCP10HD powerProcessorboard0607(X1)(O200)(X12)(X8)(X10)(X5)(X11)(X4)(X7)(X10)(X13)2.2 Fault fl ow chartHDR 1Fault symptom: - TV: Fault - V.Tuner: OK - HD: OKPossible causes: - Splitter defect - Splitter circuit on A/V boardCheck connectionAnt out - TVOK?Reestablish connectionReplace A/V
16、board PCB2Fault symptom: - TV: Fault - V.Tuner: Fault - HD: OKPossible causes: - Splitter defect - Splitter circuit on A/V boardCheck connectionAntenna - Ant inputOK?Reestablish connectionReplace A/V board PCB2NoYesFault fl ow chartFault fl ow chart 2.3 Fault symptom: - TV: Fault - V.Tuner: Fault -
17、HD: FaultPossible causes: - Power supply defect - A/V board defectMains suppliedApply mainsCheck fuseOK?Replace fuseCheck output from power supply O200- - - - - - - -Power supply (01)Replace power supplyPCB1Replace A/V boardPCB2NoYesA/V BoardPCB2Power supplyPCB12W+12V+12V+5V+5V+3.3V+5V_A+5V_D+2.5V+3
18、.3V+3.3V+2.5V+40V+40V+32V+8V+8V-8V-8V+32V+5V_SB+5V_SBMainsFuseO2002.4 Fault fl ow chartFault symptom: - TV: OK - V.Tuner: Fault - HD: FaultPossible causes: - Connection HDR 1 - TV failure - Power supply failure - A/V board failureCheck connectionHDR 1 - TV- - - - - - - -Scart connectionReestablish c
19、onnectionReplace Power supply PCB1Replace A/V board PCB2Fault symptom: - TV: OK - V.Tuner: Fault - HD: OKPossible causes: - Power supply failure - A/V board failureCheck power supply outputOK?- - - - - - - -Power supply, PCB1Replace Power supply, PCB1Replace A/V board, PCB2NoYesCheck power supply ou
20、tputOK?- - - - - - - -Power supply, PCB1A/V BoardPCB2Power supplyPCB12W+12V+12V+5V+5V+3.3V+5V_A+5V_D+2.5V+3.3V+3.3V+2.5V+40V+40V+32V+8V+8V-8V-8V+32V+5V_SB+5V_SBMainsFuseO200Fault fl ow chart 2.5 Power supplyPCB1A/V BoardPCB2Hard discCodecHD unitModule 9982W1W3W7W8WVoltageVoltageVoltageVoltageVideoAu
21、dioI3CFault symptom: - TV: OK - V.Tuner: OK - HD: FaultPossible causes: - HD unit - Connection to HD unitCheck HD status- - - - - - - -Enter HD menuSelect source “Hard Disc”- - - - - - - -OSD “starting up”No communication to HD unitReplace A/V boardPCB2Replace HD unitModule 998Check cable connection
22、 to HD unitOK?ReestablishconnectionReplace HD unitNoYes2.6 Fault fl ow chartConfi rm the HDR 1 is functioning OK- - - - - - - -HDR 1 functionFault symptom: - HDR 1 display - no or missing lightPossible causes: - No power - Display board failureCheck that the Mains supply is connected and applied- -
23、- - - - - -Mains supply appliedConnect Mains supplyCheck cable W5 is OK?- - - - - - - -Cable connectionReconnect cable W5Fuse on PCB1 OK?- - - - - - - -Fuse on PCB1Replace fuse on PCB1Replace Display board PCB3- - - - - - - -Display boardCheck 5v_SB at X11 pin 1- - - - - - - -5V standby supplyReplac
24、e power supply board, PCB1NoYesReplace Display board, PCB3- - - - - - - -Display boardA/V Board, PCB2Power supply, PCB12W+5V_SBMainsFuseDisplay board, PCB35W+5V_SB9911Red/Greenstandby ledO200X1X11X12Fault fl ow chart 2.7 Fault symptom: - OSD Warning “The hard disc recorder is overheating please swit
25、ch it to standby” - Standby light = blinking red/greenPossible causes: - NTC function - NTC PCB defect - W6 cable to NTC PCB defect - FAN function - FAN defect - FAN circuit defectCheck that cable W6is OK?- - - - - - - -NTC cable connectionReestablish connectionReplace / connect a new NTC PCB (PCB7)