1、 AUDIOACCESS PX-612 MULTI-ROOM AMPLIFIER PRELIMINARY SERVICE MANUAL Harman Consumer Group 250 Crossways Park Dr. Woodbury, New York 11797 RadioFans.CN 收音机爱 好者资料库RadioFans.CN 收音机爱 好者资料库MADRIGAL AUDIO LABS Procedure No: Revision: Title: PX 612 TEST PROCEDURE MP10.01-F1 Prepared By: Wayne Mergel Approv
2、ed By: Page 1 of 1 Procedure: I. Connect AC Line to PX-612, and then turn on with the power switch on rear panel. Observe LED on the front panel. It should initially be Red, then change to Amber. Watch for about 1 minute to ensure it does not turn Green. Set all six stereo/bridged switches to the st
3、ereo position (switched to right). II. Connect speaker harness to PX-612 and the speaker switch box. III. On PX-612 back panel connect Audio Source to Zone 1 Input. IV. As soon as the Audio Source is connected to Zone Inputs on the rear of the unit, the front panel LED should change from Amber to Gr
4、een. V. Make sure that the speaker switch box is set to the same number as the Audio Source is plugged into. You should be able to hear Audio in both speakers. VI. Move Right Audio Source to other Zone 1 Right RCA and listen for Audio cut off and come back on the right speaker. VII. Switch Zone 1 to
5、 bridged mode by moving switch Left. Then move Left Audio Source to the second Zone 1 Left RCA. The Audio should cut out completely on both Left and Right speakers. VIII. Switch back to stereo on Zone 1 by switching switch back to the Right (stereo mode) and move the Left RCA connector to Zone 2 and
6、 listen for the Left speaker to cut out. IX. Switch the speaker switch box to Zone 2 and listen for the Left channel to come on as the Right goes off. X. Move Left RCA to Zone 2 also. XI. Repeat steps VI through X, working through all Six Zones. XII. As each Zone is activated observe that the Green
7、LEDS inside unit light as its respective zone “sees” an Input. XIII. After testing all Six Zones disconnect Audio Source and leave unit on for several minutes. The Front panel LED should eventually change to Amber Again. XIV. This completes Testing. Purpose: The purpose of this document is to establ
8、ish a procedure for testing PX-612 units. Application: For use in the PX-612 Department Related Documents: None Equipment Needed: 1-Audio Source, 1 -Speaker Switch Box, 1-48” Speaker Wire Harness PX-612PX-612PARTS CROSS-REFERENCEDESCRIPTION023-0110-0BRIDGE RECTIFIER, KBPC25-02030-2271-0CAP, CER AX,
9、271, 10%, 50V001-1042-0CAP, CER, AX, 101, 10%, 50V, NPO030-2103-0CAP, CER, AX, 103, 10%, 50V030-2104-0CAP, CER, AX, 104, 10%, 50V030-2104-0CAP, CER, AX, 151, 10%, 50V030-2180-0CAP, CER, AX, 18 pf, 10%, 50V, NPO030-2222-0CAP, CER, AX, 222, 10%, 50V030-2224-0CAP, CER, AX, 224, 10%, 50V030-2332-0CAP, C
10、ER, AX, 332, 10%, 50V030-2334-0CAP, CER, AX, 334, 10%, 50V038-0106-0CAP, ELEC, AX TR, 106, 20%, 16V038-0107-0CAP, ELEC, AX TR, 107, 20%, 6.3V, 5X11M038-0336-0CAP, ELEC, AX TR, 336, 20%, 25V038-2106-0CAP, ELEC, AX, 106, -10/+50%, 50V038-1107-0CAP, ELEC, AX, 107, -10/+50%, 50V039-7102-0CAP, MET PAPER
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Audioaccess PX612 pwr sm 维修 电路 原理图