1、RadioFans.CN 收音机爱 好者资料库 AIRMEC RADIVET MODEL 211 PAGE 2 OF 37 www.TheValvePage.Com RadioFans.CN 收音机爱 好者资料库 AIRMEC RADIVET MODEL 211 PAGE 3 OF 37 www.TheValvePage.Com RadioFans.CN 收音机爱 好者资料库 AIRMEC RADIVET MODEL 211 PAGE 4 OF 37 www.TheValvePage.Com RadioFans.CN 收音机爱 好者资料库 AIRMEC RADIVET MODEL 211 PA
2、GE 5 OF 37 www.TheValvePage.Com RadioFans.CN 收音机爱 好者资料库 AIRMEC RADIVET MODEL 211 PAGE 6 OF 37 www.TheValvePage.Com RadioFans.CN 收音机爱 好者资料库 AIRMEC RADIVET MODEL 211 PAGE 7 OF 37 www.TheValvePage.Com RadioFans.CN 收音机爱 好者资料库 AIRMEC RADIVET MODEL 211 PAGE 8 OF 37 www.TheValvePage.Com INTRODUCTION The Ra
3、diVet has been designed and built primarily as a very compact piece of test gear for checking, aligning and locating faults in all stages of FM receivers. The facilities provided also enable tests to be carried out on Public Address equipment, tape decks, and AM broadcast receivers. Basically the Ra
4、diVet consists of three independent instruments housed in one case: an AM/FM signal generator, with crystal calibration, an audio oscillator and an oscilloscope. These three instruments, which can be used either separately or in conjunction one another, enable every function of a receiver to be thor
5、oughly investigated. The interconnections required for the different tests are set up by means of switches on the front panel. A brief summary of the facilities of the RadiVet is given in Section 2 from which an experienced service engineer will be able to work out his own methods of employing the i
6、nstrument. Full instructions for operating the RadiVet to obtain each of the facilities are given in Section 3, and the application of these facilities to testing FM and AM receivers, audio amplifiers, tape recorders and television receivers are dealt with in Sections 4 to 8. A detailed technical de
7、scription of the circuit appears in Section 9, a specification in Section 10 and maintenance instructions in Section 11. 1. SUMMARY OF FACILITIES The facilities provided by the RadiVet are listed below and further information on voltage ranges, accuracy, etc. is given in Section 10. Signal Generator
8、 The signal generator covers the frequency ranges 0 to 15 mc/s and 85 to 100 mc/s, that is the normal broadcast AM band and FM IF band, and the FM transmission band. The output is in each case obtained by mixing the outputs of two oscillators, one of which may be frequency modulated and the other am
9、plitude modulated. The signal may therefore be un-modulated, modulated with FM or AM or simultaneously with FM and AM at different modulating frequencies. In addition, signals in the bands 0-30 mc/s, 45-60 mc/s, 65-80 mc/s and 195-240 mc/s are obtainable at a lower output level (see Sect. 8). The si
10、gnal generator output is fed through a coaxial cable, to a probe unit which contains an attenuator. Output signal levels between approximately 5 micro-volts and 50 milli-volts may be obtained. 1.1. Wobbulator The signal generator may be frequency modulated at 50 c/s with a frequency sweep of up to 5
11、00 kc/s. If this signal is applied to the IF section of an FM receiver, and the resultant audio signal is applied to the Y plates of the crt in the RadiVet, a wobbulator display of either the IF filter characteristics or the discriminator or ratio detector characteristics may be obtained. The effect
12、 of trimming these circuits can be observed and the circuits aligned for optimum performance very rapidly. If a ratio detector is being aligned, since it is possible to provide simultaneous AM at a higher frequency, the wobbulator display so obtained enables the circuit to be set up correctly for op
13、timum rejection of AM. A similar procedure, using a very much lower frequency sweep, can be applied to give the response characteristics of a normal AM receiver IF filter. 1.2. Audio Oscillator An audio oscillator providing a choice of eleven fixed frequencies between 40 c/s and 15 kc/s is incorpora
14、ted in the RadiVet. This oscillator may be used for amplitude or frequency modulation of the RF oscillator, as an audio output signal for tests on audio equipment and tape recorders and to scan the X axis of the cathode ray tube. RadioFans.CN 收音机爱 好者资料库 AIRMEC RADIVET MODEL 211 PAGE 9 OF 37 www.TheV
15、alvePage.Com 1.3. Oscilloscope The crt has an associated DC coupled Y amplifier and time-base. The frequency response extends from DC up to 1 mc/s and in conjunction with the saw-tooth time-base generator, provides a useful oscilloscope for general waveform investigations. The Y attenuator is calibr
16、ated, and in conjunction with a calibrated Y-shift control, enables the amplitude of any observed waveform to be measured. 1.4. DC valve voltmeter The cathode ray tube, calibrated “Y” attenuator, and calibrated “Y-shift” control form a DC valve voltmeter which enables voltages to be measured without
17、 placing an appreciable loss on the circuit. This is particularly useful when measuring the potentials of valve electrodes, where an appreciable current drawn by the measuring instrument can completely change the voltage and provide very misleading results. 1.5. AC Valve Voltmeter As mentioned in th
18、e paragraph dealing with the oscilloscope facility above, the amplitude of a waveform displayed on the crt may be measured by means of the Y attenuator and calibrated Y- shift control. The input impedance is high, as in the case of DC measurements, and the instrument therefore operates as an AC valv
19、e voltmeter at 50 c/s and audio frequencies. 1.6. Frequency Calibrator The instrument contains a 5 mc/s crystal oscillator that may be used to calibrate the output frequency to a very high degree of accuracy. 1.7. Suitability for AC/DC receivers The chassis and earth line of the RadiVet are isolated
20、 from earth and from the case, and the instrument may therefore safely be used with AC/DC sets where the chassis may be live relative to earth. 2. OPERATION 2.1. Initial Adjustment The RadiVet is supplied complete and ready for use. All probes are permanently connected, and a mains lead is provided
21、to which a plug should be connected. The red, black and green leads are live, neutral and earth respectively and it is important that the earth lead should be connected to ensure correct screening. The RadiVet is despatched with the mains tapping panel set for operation on 230 volt supplies. If oper
22、ation on supplies of different voltage is required, the fused plug on the tapping panel, which is accessible inside the right-hand probe storage aperture, should be moved to the required tap. 2.2. Frequency Calibration If the full accuracy of the frequency calibration of which the RadiVet is capable
23、 is to be realised, it is necessary before use to reset the scale by means of the trimmer C75, which is located in the right- hand compartment of the case, as shown in Fig. 2. It is also desirable, where freedom from drift is essential, (for instance when operating on the Long and Medium broadcast b
24、ands) for the instrument to have been switched on for a period of at least twenty minutes. The normal procedure for crystal calibration is as follows:- (a) Set the tuning dial accurately to the check-point nearest to the frequency at which the instrument is to be used. The check-points at 2.5 mc/s i
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Airmec_211 维修电路原理图 维修 电路 原理图