sony_icf-s79_service_manual 电路图 维修原理图.pdf
《sony_icf-s79_service_manual 电路图 维修原理图.pdf》由会员分享,可在线阅读,更多相关《sony_icf-s79_service_manual 电路图 维修原理图.pdf(16页珍藏版)》请在收音机爱好者资料库上搜索。
1、ICF-S79 FM/AM SYNTHESIZED RADIO ICF-S79L FM/MW/LW SYNTHESIZED RADIO ICF-S79V TV/WEATHER/FM/AM SYNTHESIZED RADIO MICROFILM US Model ICF-S79V AEP Model ICF-S79/S79L UK Model ICF-S79L SPECIFICATIONS SERVICE MANUAL ICF-S79/S79L/S79V Photo: ICF-S79V Notes on chip component replacement Never reuse a disco
2、nnected chip component. Notice that the minus side of a tantalum capacitor may be dam- aged by heat. RadioFans.CN 2 This section is extracted from instruction manual. SECTION 1 GENERAL RadioFans.CN 3 RadioFans.CN 4 Note: Follow the disassembly procedure in the numerical order given. REAR CABINET SEC
3、TION 2 DISASSEMBLY 2 six screws (BTP 3 25) 1 battery case lid 4 rear cabinet 5 antenna lead 5 BATT lead (red) 3 two claws 5 BATT lead (white) RadioFans.CN FM FREQUENCY COVERAGE ADJUSTMENT Adjust for a reading on digital voltmeter. L887.5 MHz (TV 2 ch)2.3 0.1 V (1.0 0.1 V) Confirm108.0 MHz8.5 0.5 V (
4、12.5 0.5 V) Note: Not use the FM RF signal generator in this adjustment. ( ): ICF-S79V FM TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. L687.5 MHz (TV 2 ch (59.75 MHz) CT4108.0 MHz ( ): ICF-S79V ICF-S79L only LW FREQUENCY COVERAGE ADJUSTMENT Adjust for a reading on digital voltmet
5、er. CT5153 kHz2.3 0.1 V Confirm279 kHz8.5 0.5 V Note: Not use the AM RF signal generator in this adjustment. ICF-S79L only LW TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. L5 (LW side)162 kHz CT2243 kHz AM (MW) FREQUENCY COVERAGE ADJUSTMENT Adjust for a reading on digital voltmete
6、r. L9531 kHz (530 kHz)2.8 0.1 V Confirm1,602 kHz (1,710 kHz)9.5 0.5 V Note: Not use the AM RF signal generator in this adjustment. ( ): ICF-S79V AM (MW) TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. L5 621 kHz (590 kHz) CT31,395 kHz (1,490 kHz) : ICF-S79L ( ): ICF-S79V AM IF ADJUS
7、TMENT Adjust for a maximum reading on level meter. T2455 kHz 5 Repeat the procedures in each adjustment several times, and the frequency coverage and tracking adjustments should be finally done by the trimmer capacitors. SECTION 3 ELECTRICAL ADJUSTMENTS AM (LW/MW) Section Setting: BAND switch: AM (M
8、W) or LW 0dB=1 V FM/TV Section Setting: BAND switch: FM1 or TV ICF-S79V only TV FREQUENCY COVERAGE ADJUSTMENT Adjust for a reading on digital voltmeter. L2WEATHER 2 ch1.0 0.1 V ConfirmTV 13 ch10 0.5 V Note: Not use the FM RF signal generator in this adjustment. ICF-S79V only TV TRACKING ADJUSTMENT A
9、djust for a maximum reading on level meter. L1WEATHER 2 ch (162.40 MHz) CT1TV 13 ch (215.75 MHz) ICF-S79V only TV IF ADJUSTMENT Adjust for a maximum reading on level meter. T110.7 MHz AM RF SSG 30% amplitude modulation by 400 Hz signal Output level: as low as possible Put the lead-wire antenna close
10、 to the set. + level meter speaker terminal set FM RF SSG 22.5 kHz frequency deviation by 400 Hz signal Output level: as low as possible + level meter speaker terminal set FM lead wire antenna terminal 0.01F + digital voltmeter MAIN board TP (VT) RadioFans.CN 6 Adjustment and Connection Location: FM
11、 antenna ground (JW17) L8 FM FREQUENCY COVERAGE L9 AM (MW) FREQUENCY COVERAGE L5CT3 AM (MW) TRACKING TV TRACKING (ICF-S79V only) T1 TV IF (ICF-S79V only) L2 TV FREQUENCY COVERAGE (ICF-S79V only) CT5 LW FREQUENCY COVERAGE (ICF-S79L only) TV antenna ground (JW20) FM/TV antenna input (JW18) CT1 L1 T2 A
12、M IF FM TRACKING L6 CT4 CT2L5 LW TRACKING (ICF-S79L only) MWLWL5 IC1 IC2 TP (VT) MAIN BOARD (Component Side) MAIN BOARD (Conductor Side) RadioFans.CN Note on Printed Wiring Board: : parts extracted from the component side. : indicates side identified with part number. : internal component. : Pattern
13、 from the side which enables seeing. 7 8 ICF-S79/S79L/S79V MarkCenter frequency red10.70 MHz blue10.67 MHz orange10.73 MHz black10.64 MHz white10.76 MHz HOW TO CHANGE THE CERAMIC FILTERS This model is used two ceramic filters of CF1, CF3. You must use same type of color marked ceramic filters in ord
14、er to meet same specifications. Therefore, the ceramic filter must change two pieces together since its supply two pieces in one package as a spare parts. mark CF1 CF3 SECTION 4 DIAGRAMS 4-1.PRINTED WIRING BOARDS Semiconductor Location D1G-1Q1F-1 D2F-1Q2E-4 D3E-2Q3I-6 D4E-4Q4G-7 D5H-2Q5E-6 D6H-7Q6B-
15、7 D7G-6Q7H-6 D8F-7Q9E-5 D9E-2Q10D-6 D10B-2Q11C-2 D11B-2Q12A-2 D12C-7Q13D-7 D13C-7Q14C-7 D14H-7Q15D-2 Q16D-1 IC1F-2Q17A-3 IC2E-7 IC3C-7 IC4C-6 IC5C-6 IC6B-5 Ref. No.LocationRef. No.Location RadioFans.CN 9 10 ICF-S79/S79L/S79V Note on Schematic Diagram: All capacitors are in F unless otherwise noted.
16、pF: F 50 WV or less are not indicated except for electrolytics and tantalums. All resistors are in and 1/4 W or less unless otherwise specified. : internal component. : panel designation. B+ : B+ Line. : adjustment for repair. Power voltage is dc 4.5 V and fed with regulated dc power supply from bat
17、tery terminal. Voltages and waveforms are dc with respect to ground under no-signal (detuned) conditions. no mark : FM (TV 2 6 ch) () : AM (MW) : LW 4-2.SCHEMATIC DIAGRAM (ICF-S79/S79L) See page 11 for Waveforms and IC Block Diagrams. Voltages are taken with a VOM (Input impedance 10 M). Voltage var
18、iations may be noted due to normal production tolerances. Waveforms are taken with a oscilloscope. Voltage variations may be noted due to normal production tolerances. Circled numbers refer to waveforms. Signal path. : FM : AM (MW/LW) RadioFans.CN 4-3.SCHEMATIC DIAGRAM (ICF-S79V) See page 11 for Wav
19、eforms and IC Block Diagrams. 11 12 Note on Schematic Diagram: All capacitors are in F unless otherwise noted. pF: F 50 WV or less are not indicated except for electrolytics and tantalums. All resistors are in and 1/4 W or less unless otherwise specified. : internal component. : panel designation. :
20、 B+ Line. : adjustment for repair. Power voltage is dc 4.5 V and fed with regulated dc power supply from battery terminal. Voltages and waveforms are dc with respect to ground un- der no-signal (detuned) conditions. no mark : FM (TV 2 6 ch) () : AM : TV (7 13 ch) Voltages are taken with a VOM (Input
21、 impedance 10 M). Voltage variations may be noted due to normal production tolerances. Waveforms are taken with a oscilloscope. Voltage variations may be noted due to normal production tolerances. Circled numbers refer to waveforms. Signal path. : FM : AM : TV ICF-S79/S79L/S79VRadioFans.CN 13 Wavefo
22、rms 1 IC6 (XIN) 2 Vp-p 13.3 s 2 IC6 # # (COM0 COM3) 3 Vp-p 32 ms 3 IC6 # $ (LCD0 LCD13) 3 Vp-p 32 ms 4 D11 ANODE 440 ns 30 Vp-p 5 Q11-1 COLLECTOR 6 Vp-p 360 ns IC Block Diagrams IC1TA7358P (ICF-S79V only) 123456789 RF AMP REGULATORBIAS MIXOSC RF IN BYPASS RF OUT MIX GND MIX OUT OSC OUT OSC VCC 12345
23、6789101514131211 FM DISCRIMINATOR AF POWER AMPAM FEFM IF TUNING METER AM IF DET AGC FM FE 232221202425191817162928272630 GND GND AF OUT VCC RIPPLE FILTER AF IN DET OUT AFC AGC AFC AGC IF GND METER N.C FM IF IN AM IF IN FM/AM BAND SELECT FM/AM IF OUT N.C FE GND AM RF IN FM RF REG OUT FM OSC FM RF IN
24、AFC AM OSC VOL NF FM DISCRI GND GND RadioFans.CN 14 Pin No.Pin NameI/OFunction 1INIT OUTOInitialize signal output for the destination select 2POWERORadio power on/off control signal output “H”: power on 3MUTEOMute on/off control signal output “L”: mute on 4AL LEVELOBeep sound level variable output t