GrundigUMS4600DECServiceManual2 维修电路图、原理图.pdf
《GrundigUMS4600DECServiceManual2 维修电路图、原理图.pdf》由会员分享,可在线阅读,更多相关《GrundigUMS4600DECServiceManual2 维修电路图、原理图.pdf(11页珍藏版)》请在收音机爱好者资料库上搜索。
1、VERTIGA UMS 4600 DEC GLR1200 Zustzlich erforderliche Unterlagen fr den Komplettservice Additionally required Service Documents for the Complete Service Service Manual Service Manual HiFiService Manual 1. Ergnzung / Supplement 1 Materialnummer/Part Number 720107740100 nderungen vorbehalten/Subject to
2、 alteration TCC 1207 HH Prepared in Germany NUR FR INTERNEN GEBRAUCH FOR INTERNAL USE ONLY UMS 4600 Materialnr./Part No. 720107740000 Sicherheit Safety Materialnr./Part No. 720108000001 GRUNDIG ServiceVERTIGA UMS 4600 DEC 2 Es gelten die Vorschriften und Sicherheitshin- weise gem dem Service Manual
3、Sicherheit, Materialnummer 720108000001, sowie zustz- lich die eventuell abweichenden, landes- spezifischen Vorschriften! The regulations and safety instructions shall be valid as provided by the Safety Service Manual, part number 720108000001, as well as the re- spective national deviations! Table
4、of Contents Page General Section. 2 Introduction . 2 General Notes . 2 Layout of PCBs and Circuit Diagrams . 3 9 Amplifier . 3 Main PCB . 4 CD Section . 7 Exploded Views and Spare Parts List . 10 11 Exploded Views . 10 Spare Parts List . 11 Inhaltsverzeichnis Seite Allgemeiner Teil . 2 Einfhrung. 2
5、Allgemeine Hinweise. 2 Platinenabbildungen und Schaltplne . 3 9 Verstrker . 3 Hauptplatte. 4 CD-Teil . 7 Explosionszeichnungen und Ersatzteilliste . 10 11 Explosionszeichnungen . 10 Ersatzteilliste . 11 General Section Introduction This Supplement of Service Manual describes changed circuit dia- gra
6、ms and PCB illustrations. These changed PCBs are used from serial number 28801 on. Note: Basic instructions for servicing are given in the following Service Manuals: Service Manual Safety, Part Number 720108000001 Service Manual UMS 4600, Part Number 720107740000 General Notes Before opening the cab
7、inet disconnect the mains plug! Attention: Observe the ESD safety regulations Wiring Before disconnecting any leads and especially the earth connecting leads observe the way they are routed to the individual assemblies like the chassis, mains switch panel, keyboard control panel, picture tube panel,
8、 deflection unit, loudspeaker and so on. On completion of the repairs the leads must be laid out as originally fitted at the factory to avoid later failures or disturbances. Carrying out Measurements When making measurements on semi-conductors with an oscillo- scope, ensure that the test probe is se
9、t to 10:1 dividing factor. If the previous measurement was made on AC input, please note that the coupling capacitor in the oscilloscope will be charged. Discharge via the item being checked can damage the components. Measured Values The measured values given in the circuit diagrams are approximates
10、! Allgemeiner Teil Einfhrung In dieser Service-Manual-Ergnzung sind genderte Schaltplne und Leiterplattenabbildungen dokumentiert. Diese genderten Leiterplatten werden ab Seriennummer 28801 verwendet. Hinweis: Grundlage fr den Service sind folgende Service Manuals: Service Manual Sicherheit, Materia
11、lnummer 720108000001 Service Manual UMS 4600, Materialnummer 720107740000 Allgemeine Hinweise Vor dem ffnen des Gehuses zuerst den Netzstecker ziehen! Achtung: ESD-Vorschriften beachten Leitungsverlegung Bevor Sie die Leitungen und insbesondere die Masseleitungen lsen, muss die Leitungsverlegung zu
12、den einzelnen Baugruppen beachtet werden. Nach erfolgter Reparatur ist es notwendig, die Leitungsfhrung wieder in den werkseitigen Zustand zu versetzen um evtl. sptere Ausflle oder Strungen zu vermeiden. Durchfhren von Messungen Bei Messungen mit dem Oszilloskop an Halbleitern sollten Sie nur Tastkp