GrundigSonoclock900 维修电路图、原理图.pdf
《GrundigSonoclock900 维修电路图、原理图.pdf》由会员分享,可在线阅读,更多相关《GrundigSonoclock900 维修电路图、原理图.pdf(10页珍藏版)》请在收音机爱好者资料库上搜索。
1、M 7-C / M 17-C / M 27-CAllgemeiner Teil / General Section GRUNDIG Service1 - 1 Service Manual Audio sonoclock 900 Zustzlich erforderliche Unterlagen fr den Komplettservice Additionally required Service Manuals for the Complete Service Service Manual Service Manual Btx * 32700 # Sachnummer Part Numbe
2、r 72010-754.45 nderungen vorbehalten Subject to alteration Printed in Germany VK231 0797 sonoclock 900 Sach-Nr./Part No. 72010-754.45 Sicherheit Safety Sach-Nr./Part No. 72010-800.00 p SONOCLOCK 900 PRESETALARMAL. MODESLEEP ? 23.15:30 FM IIIIAL6.15 1 - 2GRUNDIG Service Allgemeiner Teil / General Sec
3、tionsonoclock 900 Es gelten die Vorschriften und Sicherheitshin- weise gem dem Service Manual Sicherheit, Sach-Nummer 72010-800.00, sowie zustzlich die eventuell abweichenden, landesspezifischen Vorschriften! The regulations and safety instructions shall be valid as provided by the Safety Service Ma
4、nual, part number 72010-800.00, as well as the respective national deviations. k Table of Contents Page General Section. 1 - 2 Test Equipment / Aids . 1 - 2 Adjustment Procedures.2 - 1 Circuit Diagrams and Layout of the PCBs. 3 - 1 3 - 7 Circuit Diagrams: Main Board . 3 - 2 Clock-, Volume-, Function
5、-, Jack Board. 3 - 4 Layout of the PCBs: Main Board . 3 - 1 Clock-, Volume-, Function-, Jack Board. 3 - 6 Exploded View and Spare Parts List. 4 - 1 4 - 2 Exploded View . 4 - 1 Spare Parts List . 4 - 2 j Inhaltsverzeichnis Seite Allgemeiner Teil . 1 - 2 Megerte / Memittel . 1 - 2 Einstellvorschriften
6、.2 - 1 Schaltplne und Platinenabbildungen . 3 - 1 3 - 7 Schaltplne: Main Board . 3 - 2 Clock-, Volume-, Function-, Jack Board. 3 - 4 Platinenabbildungen: Main Board . 3 - 1 Clock-, Volume-, Function-, Jack Board. 3 - 6 Explosionszeichnung und Ersatzteilliste . 4 - 1 4 - 2 Explosionszeichnung . 4 - 1
7、 Ersatzteilliste . 4 - 2 Allgemeiner Teil Megerte / Memittel Trenntrafo Mesender Digitalvoltmeter NF-Voltmeter Beachten Sie bitte das GRUNDIG Metechnik-Programm, das Sie unter folgender Adresse erhalten: GRUNDIG Instruments Test- und Mesysteme GmbH Wrzburger Str. 150, D-90766 Frth/Bay Tel. 0911/703-
8、4118, Telefax 0911/703-4130 General Section Test Equipment / Aids Isolating Transformer Test Generator Digital Voltmeter AF Voltmeter Please note the Grundig Catalog “Test and Measuring Equipment” obtainable from: GRUNDIG Instruments Test- und Mesysteme GmbH Wrzburger Str. 150, D-90766 Frth/Bay Tel.
9、 0911/703-4118, Telefax 0911/703-4130 sonoclock 900Einstellvorschriften / Adjustment Procedures GRUNDIG Service2 - 1 j Einstellvorschriften Megerte: Mesender, Digitalvoltmeter, NF-Voltmeter AbgleichVorbereitung Abgleichvorgang Die Frequenz ist werkseitig mit TC201 auf 16384Hz 0,04Hz eingestellt. Mit
10、 VR102 Abstimmspannung auf 1,7V 0,15V einstellen. Mit L103 bei 87,5MHz Maximum einstellen. Mit TC102 bei 108MHz Maximum einstellen. Abgleich wechselseitig wiederholen. Mit L102 bei 88MHz Maximum einstellen. Mit TC101 bei 106MHz Maximum einstellen. Abgleich wechselseitig wiederholen. 1. Quarz Oszilla
11、tor (Uhr) 2. Abstimm- spannung 3. FM Oszillator 4. FM Vorkreis Pin 28 IC201 kurzzeitig zur Aktivierung der Uhrfrequenz an Masse (GND) legen. Frequenzzhler an Pin11 IC201, (Testpunkte siehe Seite 3-6 Clock Board). FM, auf niedrigste Frequenz abstimmen. Digitalvoltmeter an Mepunkt VTUN. FM, 87,5MHz/10
12、8MHz Mesendersignal an Antenneneingang (fmod = 1kHz, f = 22,5kHz). NF-Voltmeter an NF-Ausgang. Einen Abstimmspeicher auswhlen und auf unteren An- schlag einstellen. Abstimmspeicher auf oberen Anschlag einstellen. FM, 88MHz/106MHz Mesendersignal an Antenneneingang (UA , f = 22,5kHz). NF-Voltmeter an
13、NF-Ausgang. Adjustment Procedures Test Equipment: Test Generator, Digital Voltmeter, AF Voltmeter k AdjustmentPreparations Adjustment Procedure For activating the clock frequency connect pin 28 IC201 for a short time to ground (GND). Frequency counter to Pin11 IC201. (Testpoints see page 3-6 Clock B
14、oard). FM, tune the selected preset to lowest frequency. Digital voltmeter to testpoint VTUN. FM, 87,5MHz/108MHz Couple in a standard signal to antenna input (fmod = 1kHz, f = 22.5kHz). AF voltmeter to AF output. Select a pre-set pot and tune to lowest frequency. Tune this pre-set pot to highest fre
15、quency. FM, 88MHz/106MHz Couple in a standard signal to antenna input (UA = , f = 22.5kHz). AF voltmeter to AF output. The frequency is set to 16384Hz 0.04Hz with TC201 in the factory. With VR102 adjust the tuning voltage to 1.7V 0.15V. At 87.5MHz adjust to maximum with L103. At 108MHz adjust to max
16、imum with TC102. Repeat this adjustment. At 88MHz adjust to maximum with L102. At 106MHz adjust to maximum with TC101. Repeat this adjustment. 1. Quartz oscillator (Clock) 2. Tuning voltage 3. FM Oscillator 4. FM Aerial bandpass TC101 TC102 L103 L102 GND ANT. IN NF/AF OUT VTUN D103 JP103 JP101JP102
17、IC101 MAIN BOARD VR102 Schaltplne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBssonoclock 900 3 - 1GRUNDIG Service Main Board Component side + GND -24.9V F2 F1 ON DC-VOL UREF AGND DO CE DI CL T O N E CONTROL HEADPHONE SPEAKER TRANSF. AC 9V TRANSF. AC 4V TRANSF. AC 27V FM ANT. IN O
18、UT ADJ Schaltplne und Druckplattenabbildungen Circuit Diagrams and Layout of PCBs sonoclock 900Schaltplne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBssonoclock 900Schaltplne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs GRUNDIG Service3 - 2GRUNDIG Service3 -
19、3 Main Board 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 5.8V 1.1V 2.5V 1.3V 1.3V 1.2V 0.3V 1.3V 1.1V 2.5V 1.0V 1.2V 0V 1.4V 6.3V 6.9V VTUN TUNING VOLTAGE 11V -24V -24.9V-32.5V 20V 10V 27V AC 4V AC 9V AC 7V 7.6V 6.9V 10.5V 7.6V 0V 0V 0.6V 0V ? TO JP303 JACK BOARD
20、 PAGE 3-5 TO JP201 CLOCK BOARD PAGE 3-4 TO JP202 CLOCK BOARD PAGE 3-4 11V Schaltplne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBssonoclock 900Schaltplne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBssonoclock 900 3 - 4GRUNDIG Service3 - 5GRUNDIG Service CLOCK
21、BOARD DISPLAY Clock Board Volume Board Function Board Jack Board 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 34 35 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 49 50 51
22、52 53 54 55 56 57 58 59 60 61 62 63 64 -24.8V 0.9V 4.6V 4.6V 4.6V 4.6V 4.6V 2.3V -4.4V 4.6V 0.7V 4.6V 1.8V 2.1V 2.1V 1.9V 0.8V 4.6V 0.3V 4.7V -24.9V 4.7V 4.7V 0V 0.7V 5.2V 4.7V10.5V 3.9V 4.6V 0V 4.6V 0.4V 0.5V 2.7V 1.25V 0V VOLUME BOARD FUNCTION BOARD JACK BOARD TO JP101/102 MAIN BOARD PAGE 3-2 TO J
23、P105 MAIN BOARD PAGE 3-3 TO JP112 MAIN BOARD PAGE 3-3 DCF77 sonoclock 900Schaltplne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs GRUNDIG Service3 - 6 Clock Board Component side Clock Board Solder side PIN11 (IC201)PIN28 (IC201) GNDTC201 1 2 3 4 5 6 7 8 3 2 1 1 2 3 4 5 1 2 3 4 5
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Grundig Sonoclock900 维修电路图、原理图 维修 电路图 原理图