SphinxProject-12-pwr-sm维修电路原理图.pdf
《SphinxProject-12-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《SphinxProject-12-pwr-sm维修电路原理图.pdf(23页珍藏版)》请在收音机爱好者资料库上搜索。
1、1. SERVICE MANUAL PROJECT TWELVE MONO POWER AMPLIFIER RadioFans.CN 收音机爱 好者资料库 SPHINX Project Twelve Service Manual 2 Contents 1. UNPACKING.3 2. SPHINX WARRANTY CARD .3 3. CONTACTING THE MANUFACTURER.3 4. THE POWER AMP AT A GLANCE.4 Front panel.4 Rear panel .5 5. TECHNICAL SPECIFICATIONS.6 6. GENERAL
2、 CHECKLIST.7 Optical connections .7 Switching the amp on.7 Protection mode.7 Cables.7 7. USING THE AMP WITHOUT PROTECTION CIRCUIT.8 Removing the protection circuit board .8 Repositioning the protection circuit board.8 8. ADJUSTMENT PROCEDURES.9 Bias.9 Offset .10 Common mode .10 9. PROBLEMS AND SOLUT
3、IONS.11 10. DIAGRAMS AND PARTS LISTS .12 Connection diagram for testing the project 12.13 Schematic layout of project 12 with securityprint.14 Schematic layout of all relevant parts.15 Project 12 amplifier diagram.16 Project 12 protection diagram.17 PCB drawings of Project 12.18 Partlist amplifier .
4、19 Partlist protection.22 RadioFans.CN 收音机爱 好者资料库 SPHINX Project Twelve Service Manual 3 The Sphinx Project Twelve design The Sphinx Project Twelve was designed for the ever-increasing group of quality-conscious audiophiles. We are very proud of the tradition connected with the SPHINX name, especial
5、ly concerning audio quality perfection. This service manual will help you to optimally service and repair the Sphinx Project Twelve Mono Power Amplifier. The design is based on the long experience of the Sphinx design team with ultra-wide bandwidth power FETs. These have an unique and extremely wide
6、 power bandwidth exceeding 1.5 MHz, a very high slew rate of over 100 V/s and an unequalled perfect phase linearity over the complete frequency bandwidth. Six of these 100 W FETs are used to obtain maximum reliability. The extremely low output impedance results in a damping factor of over 600! Toget
7、her with the very heavy power supply and its large energy buffer of 26,920 F, this results in an effortless sound with a very large dynamic range and an unsurpassed transient response. Much attention has also been paid to the physical layout, the positioning of components and the internal grounding.
8、 This results in an equivalent input noise value of 1 V (-120 dBV): remarkable for a pre-amp, but really astounding for a big power amp with two transformers. All of this means that the Project Twelve can work with all kind of loads from every loudspeaker: even the most difficult ones like electrost
9、atic and magnetostatic. To obtain the maximum quality from this power amp it is necessary to use it with top quality audio components preferably with other Sphinx components. 1. UNPACKING Before leaving the factory every Project Twelve is subjected to stringent and extensive technical and exterior q
10、uality inspections. This ensures the user many years of high quality audio from a perfect- looking product. We recommend owners to ship the Project Twelve in its original carton. After unpacking the Project Twelve we therefore recommend you carefully check it for any transport damage. If you find an
11、y damage and the product has not been shipped in the original carton the ensuing repair costs will not be covered by the warranty. 2. SPHINX WARRANTY CARD To be entitled to any warranty repairs the owner must have send the filled out warranty card to Sphinx or a distributor where it has been registe
12、red. Other regulations may apply in your specific country: when in doubt, please consult the proper authorities. 3. CONTACTING THE MANUFACTURER In case of any problem not covered in this manual or if you have other questions you may contact the Sphinx International Service Department in The Netherla
13、nds (local time: GMT +1h) during office hours at the following numbers: Telephone(+31) 35 602 0302 Fax(+31) 35 602 2806 E-mailaudionleuronet.nl It is always very helpful and efficient if you have all relevant information about the specific product and the problem ready. Please also refer to the User
14、 Manual of the Project Twelve for information about functions not described in this manual. It is important to familiarise yourself with the special functions, operation and possibilities of the Sphinx Project Twelve. SPHINX Project Twelve Service Manual 4 4. THE POWER AMP AT A GLANCE Front panel 1.
15、 LED: Indicates the selected function: stand-byred ongreen protectionblinking red. 2. STANDBY: To switch the component on and off. SPHINX Project Twelve Service Manual 5 Rear panel 3. BALANCED/UNBALANCED: With this switch you may select the balanced input (5.) or the unbalanced input (8). 4. CONTROL
16、 IN: To connect the optical cable from another Sphinx component like a pre-amp. CONTROL OUT: To connect the optical cable that goes to another Sphinx component. 5. BALANCED INPUT: To connect the balanced XLR cable from the pre-amp output. 6. MAINS: This is the combined mains master switch (0/1) and
17、input. MAINS: To connect the power amp to a mains outlet (230 - 240 VAC). 7. OUTPUT: To connect the cable from the loudspeaker: red+ white- 8. UNBALANCED INPUT: To connect the unbalanced cinch cable from the pre-amp output. Manufacturers label: Here youll find important data on this component, such
18、as serial number and mains voltage to be used. SPHINX Project Twelve Service Manual 6 5. TECHNICAL SPECIFICATIONS Bandwidth0 - 1.5 MHz (+0/-3 dB) 0 - 203,000 Hz after RF input filter Phase response error151 W into 8 ohm (21.8 dBW), THD 246 W into 4 ohm (23.9 dBW), THD 340 W into 2 ohm (25.3 dBW), TH
19、D 0.01% Output voltage / current, max.36 V / 16 A THD+N (IHF-A)0.006% (100 W into 8 ohm, 1 - 20,000 Hz) IMD120 dB Slew rate20 V/s Common Mode Rejection Ratio30dB 100 Hz Damping factor645 10 Hz 629 100 Hz 595 1 kHz 155 10 kHz InputXLR balanced / cinch WBT unbalanced level, nominal1.25 V (1.9 dBV) / 1