《Sony-STRDE197-rec-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Sony-STRDE197-rec-sm维修电路原理图.pdf(34页珍藏版)》请在收音机爱好者资料库上搜索。
1、1 SERVICE MANUALUS Model Canadian Model AEP Model STR-DE197 FM STEREO/FM-AM RECEIVER AUDIO POWER SPECIFICATIONS POWER OUTPUT AND TOTAL HARMONIC DISTORTION: (Models of area code US only) With 8 ohm loads, both channels driven, from 20 20,000 Hz; rated 100 watts per channel minimum RMS power, with no
2、more than 0.09 % total harmonic distortion from 250 milliwatts to rated output. Amplifier section POWER OUTPUT Models of area code US, CND Power Output at Stereo Mode (8 ohms 1 kHz, THD 0.7 %) 125 W + 125 W 1) Models of area code AEP Power Output at Stereo Mode (8 ohms 1 kHz, THD 0.7 %) 100 W + 100
3、W 1) 1) Measured under the following conditions: Area codePower requirements US, CND120 V AC, 60 Hz AEP230 V AC, 50 Hz Frequency response CD, MD/TAPE,20 Hz 50 kHz VIDEO 1, 2+0/0.5 dB (with bass boost and tone bypassed) Inputs (Analog) CD, MD/TAPE,Sensitivity: 500 mV VIDEO 1, 2Impedance: 50 kilohms S
4、/N 2) : 85 dB (A, 500 mV 3) ) 2) INPUT SHORT (with bass boost and tone bypassed). 3) Weighted network, input level. SPECIFICATIONS Outputs (Analog) MD/TAPE (OUT),Voltage: 500 mV VIDEO 1 (AUDIO OUT)Impedance: 10 kilohms Bass Boost:+8 dB at 70 Hz Tone:10 dB at 100 Hz and 10 kHz FM tuner section Tuning
5、 range87.5 108.0 MHz AntennaFM wire antenna Antenna terminals75 ohms, unbalanced Intermediate frequency10.7 MHz Sensitivity Mono:18.3 dBf, 2.2 V/75 ohms Stereo:38.3 dBf, 22.5 V/75 ohms Usable sensitivity11.2 dBf, 1 V/75 ohms S/N Mono:76 dB Stereo:70 dB Harmonic distortion at 1 kHz Mono:0.3% Stereo:0
6、.5% Separation45 dB at 1 kHz Frequency response30 Hz 15 kHz, +0.5/2 dB Selectivity60 dB at 400 kHz Ver. 1.2 2006. 02 9-877-864-03 2006B04-1 2006. 02 Sony Corporation Home Audio Division Published by Sony Techno Create Corporation Continued on next page Photo: Black type RadioFans.CN 收音机爱 好者资料库 2 STR
7、-DE197 AM tuner section Tuning range Models of area code US, CND With 10-kHz tuning scale: 530 1,710 kHz 4) With 9-kHz tuning scale:531 1,710 kHz 4) Models of area code AEP With 9-kHz tuning scale:531 1,602 kHz AntennaLoop antenna Intermediate frequency450 kHz Usable sensitivity50 dB/m (at 1,000 kHz
8、 or 999 kHz) S/N54 dB (at 50 mV/m) Harmonic distortion0.5 % (50 mV/m, 400 Hz) Selectivity At 9 kHz:35 dB At 10 kHz:40 dB 4) You can change the AM tuning scale to 9 kHz or 10 kHz. After tuning in any AM station, turn off the receiver. Hold down PRESET TUNING + and press ?/1. All preset stations will
9、be erased when you change the tuning scale. To reset the scale to 10 kHz (or 9 kHz), repeat the procedure. General Power requirements Area codePower consumption US, CND120 V AC, 60 Hz AEP230 V AC, 50/60 Hz Power consumption Area codePower consumption US190 W CND270 VA AEP210 W Power consumption (dur
10、ing standby mode) 0.5 W AC outlets Area codeAC outlets US, CND1 switched, 120 W/1A MAX AEP1 switched, 100 W MAX Dimensions430 132.5 302 mm (17 5 1/4 11 7/8 inches) including projecting parts and controls Mass (Approx.)7.0 kg (15 lb 7 oz) Supplied accessories FM wire antenna (1) AM loop antenna (1) R
11、emote commander RM-U185 (1) R6 (size-AA) batteries (2) Design and specifications are subject to change without notice. Abbreviation CND: Canadian model 1.5 k0.15 F AC voltmeter (0.75 V) To Exposed Metal Parts on Set Earth Ground Fig. A. Using an AC voltmeter to check AC leakage. SAFETY CHECK-OUT Aft
12、er correcting the original service problem, perform the following safety check before releasing the set to the customer: Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. LEAKAGE TEST The AC leakag
13、e from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA
14、WT-540A. Follow the manufacturers instructions to use these instruments. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job. 3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indicati
15、on is 0.75 V, so analog meters must have an accurate low-voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2V AC range are suitable. (See Fig. A) SAFETY-RELATED COMPONENT WARNING! COMPONENTS I
16、DENTIFIED BY MARK 0 OR DOTTED LINE WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY. ATTENTION AU COMPOSANT AYANT RAPPORT LA SCURI
17、T! LES COMPOSANTS IDENTIFIS PAR UNE MARQUE 0 SUR LES DIAGRAMMES SCHMATIQUES ET LA LISTE DES PICES SONT CRITIQUES POUR LA SCURIT DE FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS QUE PAR DES PICES SONY DONT LES NUMROS SONT DONNS DANS CE MANUEL OU DANS LES SUPPLMENTS PUBLIS PAR SONY. RadioFans.CN 收音机爱 好者
18、资料库 3 TABLE OF CONTENTS 1. GENERAL Main unit . 4 Remote button description. 6 2. DISASSEMBLY 2-1. Case . 7 2-2. Front Panel Section . 8 2-3. Back Panel. 8 2-4. Main Board . 9 3. TEST MODE. 10 4. DIAGRAMS 4-1. IC Pin Description. 11 4-2. Circuit Boards Location . 13 4-3. Block Diagram Main Section .1
19、5 4-4. Block Diagram Power Section . 16 4-5. Printed Wiring Boards Main Section .17 4-6. Schematic Diagram Main Section (1/2) .18 4-7. Schematic Diagram Main Section (2/2) .19 4-8. Printed Wiring Boards Panel Section .20 4-9. Schematic Diagram Panel Section .21 4-10. IC Block Diagrams. 22 5. EXPLODE
20、D VIEWS 5-1. Case Section .23 5-2. Front Panel Section .24 5-3. Chassis Section . 25 6. ELECTRICAL PARTS LIST. 26 STR-DE197 MODEL IDENTIFICATION BACK PANEL Part No. MODELPART No. US4-253-299-0s AEP4-253-299-1s CND4-253-299-3s Abbreviation CND: Canadian model 4 STR-DE197 SECTION 1 GENERALThis section
21、 is extracted from instruction manual. 5 STR-DE197 6 STR-DE197 7 STR-DE197 Note : This set can be disassemble according to the following sequence. SECTION 2 DISASSEMBLY 2-1. CASE 2-1.CASE (Page 7) 2-2.FRONT PANEL SECTION (Page 8) 2-3.BACK PANEL (Page 8) SET 2-4.MAIN BOARD (Page 9) Note : Follow the
22、disassembly procedure in the numerical order given. 1 two screws (case 3 TP2) 2 two screws (case 3 TP2) 3 two screws (case 3 TP2) 4 case 8 STR-DE197 2-2. FRONT PANEL SECTION 2-3. BACK PANEL 6 front panel section 4 two screws (BVTP3 x 8) 1 CNS2 2 CNS3 3 CNP801 5six screws (BVTP3 x 8) 1 connector 2 CN
23、P905 3 CNP901 4 three screws (BVTP3 x 8) 6 two screws (BVTP3 x 8) 7 two screws (BVTP3 x 8) 5 two screws (BVTP3 x 8) 8 back panel (DE10) 9 STR-DE197 2-4. MAIN BOARD 5 two screws (+BV SUMITITE (B3) 6 screw (+BV SUMITITE (B3) 8 MAIN board 7 screw (+BV SUMITITE (B3) 4 two screws (+BV SUMITITE (B3) 1 CNP
24、9023 CNP904 2 CNP903 10 STR-DE197 SECTION 3 TEST MODE Fluorescent Indicator Tube Test Mode All fluorescent segments are tested. When this test is activated, all segments turn on at the same time, then each segment turns on one after another. Procedure: 1. While depressing the VIDEO 1, VIDEO 2, MD/TA
25、PE, CD and the TUNER buttons simultaneously, press the ?/1 button to turn on the main power. 2. The FL tube will illuminate in half light on. The following dis- play will be repeated whenever the five function buttons are pressed. Operation of function buttons 3. Press any button other than the func
26、tion buttons to release the check mode. AUTO-BETICAL Check Mode (AEP model) To auto-scanning and memories of RDS station. Procedure: 1. While depressing the MEMORY/ENTER button, press the ?/1 button to turn on the main power. 2. The message “AUTO-BETICAL SELECT” are scrolled for a moment and the rec
27、eiver starts scanning. AM Tuning Interval Selection Mode (US, Canadian model) Either 9 kHz step or 10 kHz step can be selected for the AM tuning interval. Procedure: 1. While depressing the PRESET TUNING + button or the TUN- ING/CHAR + button, press the ?/1 button to turn on the main power. 2. Eithe
28、r the message “9k STEP” or “10k STEP” appears for a moment and select the desired step. Software Version Display Mode The software version is displayed. Procedure: 1. While depressing the SPEAKER B and the VIDEO 1 buttons simultaneously, press the ?/1 button to turn on the main power. 2. The destina
29、tion and the software version are displayed for a moment. all light on half light on 1 half light on 2 all light off ex.)US, Canadian model : U *.* AEP model : CE *.* Area Software version 11 STR-DE197 SECTION 4 DIAGRAMS 1 to 7DIG7 to DIG1ODigit drive signal output to the vacuum fluorescent display
30、(FL201). 8+5VPower supply pin (+5 V) 9CLOSerial clock signal output to FM/AM tuner pack. 10DOOSerial data signal output to FM/AM tuner pack. 11DIISerial data signal input from FM/AM tuner pack. 12CEOSerial chip enable signal output to FM/AM tuner pack. 13VOL DATAOSerial data signal output to sound c
31、ontrol IC. 14VOL CLOSerial clock signal output to sound control IC. 15RDS DATAIRDS data signal input from FM/AM tuner pack. (AEP model only) 16PROTECTORIOverload detection signal input 17RESETIReset signal input 18TUNEDITUNED indicator detection signal input from FM/AM tuner pack. 19STEREOISTEREO in
32、dicator detection signal input from FM/AM tuner pack. 20AVSSAnalog ground 21VERSIONIDestination select signal input (Fixed at H: US, Canadian model, L: AEP model) 22FM SIGNAL OUTI FM/AM signal meter voltage detection signal input from FM/AM tuner pack. (AEP model only) 23 to 28AD6 to AD1IFunction ke
33、ys signal input 29AVDDA/D converter power supply pin (+5 V) 30AV.REFA/D converter reference voltage input (+5 V) 31Not used. (Connect to AV.REF pin in this set) 32OPENNot used. (Open) 33GNDGround 34X1IMaster clock input (4.19 MHz) 35X2OMaster clock output (4.19 MHz) 36REC SW1OVIDEO 1 ON/OFF signal o
34、utput 37REC SW2OMD/TAPE ON/OFF signal output 38, 39VOL A, VOL BIMaster volume JOG data input A, B 40FUNC.MUTEONot used. (Fixed at L in this set) 41CKOSerial clock signal output to electronic volume IC. 42DATAOSerial data signal output to electronic volume IC. 43STBOSerial data strobe signal output t
35、o electronic volume IC. 44SYS.POWERISystem power signal input 45AC MUTEOA-Class mute signal output 46RDS INTIRDS clock signal input from FM/AM tuner pack. (AEP model only) 47STOPIStop signal input from reset/+5.6V regulator IC. 48VSSGround 49SIRCSISircs signal input from remote control receiver IC.
36、50TUNER MUTEOMuting control signal output to FM/AM tuner pack. 51Not used. (Open) 52+5VPower supply pin (+5 V) 53BASS B. LEDOBASS BOOST LED drive signal output 54SPK A LEDOSPEAKER A LED drive signal output 55SPK B LEDOSPEAKER B LED drive signal output 4-1. IC PIN DESCRIPTION IC201 PD78045FGF-134-3B9
37、 (SYSTEM CONTROLLER, FL DISPLAY DRIVER) Pin No.Pin NameI/OPin Description 12 STR-DE197 56RY R1 COILOPower relay (12V) drive signal output 57RY POWEROAC power relay (9V) drive signal output 58RY AOSpeaker A relay (12V) drive signal output 59RY BOSpeaker B relay (12V) drive signal output 60RY HPOPhone
38、s relay (12V) drive signal output 61Not used. (Open) 62 to 70S15 to S7OSegment drive signal output to the vacuum fluorescent display (FL201). 71VLOADPower supply pin (24 V) 72 to 77S6 to S1OSegment drive signal output to the vacuum fluorescent display (FL201). 78 to 80DIG10 to DIG8ODigit drive signa
39、l output to the vacuum fluorescent display (FL201). Pin No.Pin NameI/OPin Description 13 STR-DE197 4-2. CIRCUIT BOARDS LOCATION AC OUTLET board MAIN board FUNCTION KEY board VOLUME board DISPLAY board POWER board H.PHONE board 14 STR-DE197 THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC
40、DIAGRAMS. (In addition to this, the necessary note is printed in each block.) for schematic diagram: All capacitors are in F unless otherwise noted. (p: pF) 50 WV or less are not indicated except for electrolytics and tantalums. All resistors are in and 1/4 W or less unless otherwise specified. f: i
41、nternal component. 2 : nonflammable resistor. 1 : fusible resistor. C : panel designation. A : B+ Line. B : B Line. Voltage and waveforms are dc with respect to ground under no-signal (detuned) conditions. no mark : FM Voltages are taken with a VOM (Input impedance 10 M). Voltage variations may be n
42、oted due to normal produc- tion tolerances. Waveforms are taken with a oscilloscope. Voltage variations may be noted due to normal produc- tion tolerances. Circled numbers refer to waveforms. Signal path. F: TUNER (FM/AM) L: VIDEO (AUDIO) J: CD (ANALOG) Abbreviation CND: Canadian model. for printed
43、wiring boards: X : parts extracted from the component side. f: internal component. : Pattern from the side which enables seeing. Abbreviation CND: Canadian model. C B These are omitted. E Q B These are omitted. C Q Q E BCE Note: The components identi- fied by mark 0 or dotted line with mark 0 are cr
44、iti- cal for safety. Replace only with part number specified. Note: Les composants identifis par une marque 0 sont critiques pour la scurit. Ne les remplacer que par une pice portant le numro spcifi. STR-DE197 1515 STR-DE197 4-3. BLOCK DIAGRAM MAIN SECTION 9 7 5 3 1 1422 49712877 - 72,70 - 627 - 1,8
45、0 - 7827262524442354173435 15 4619 18 50 12 10 11 9133736 60 58 59 16 56 57 47 135 41 42 43 323112 43 3 108 1211 56 23 7 LED DRIVER Q204 LED DRIVER Q206 55 LED DRIVER Q205 KEY MATRIX FL201 VACUUM FLUORESCENT DISPLAY 1 REMOTE CONTROL RECEIVER IC202 29 2032 89 101514 385339 13 TREBLE L MIDDLE L BASS L CONTROLVOLUME CONTROL STEREO TUNED MUTE CE DI DO CL FM SIGNAL OUT RDS DATA RDS INT STEREO TUNED TUNER MUTE CE DO DI CL VOL CL VOL DATA CK DATA STB REC SW2 REC SW1 RY HP RY A RY B PROTECTOR RY R1 COIL RY POWER STOP ST-RR-CH R-CH R-CH R-CH R-CH R-CH R-CH ST-L HP RELAY SPK A RELAY RESET