1、SERVICE MANUAL COPYRIGHT 2005 Victor Company of Japan, Limited No.MB420 2005/7 DVD DIGITAL CINEMA SYSTEM MB42020057 TH-C3 Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade) TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-30 5TROUBLESHOOTING . . . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35 XV-THC3 SP-THC3F SP-PWC3 SP-THC3S SP-THC3C Area suffix UW - Brazil,Mexico,Peru UY - Argentina UJ - U.S.Military RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB420) SPECIFICATION Center unit (XV-THC3) *1: This va
5、lue is measured at System cord CONNECTOR for reference. *2: Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz) Subwoofer (SP-PWC3) Audio sectionTotal Harmonic Distortion*10.02% Digital input*2DIGITAL IN (DBS): -21 dBm to -15 dBm (
6、OPTICAL: 660 nm 30 nm) Video sectionVideo SystemPAL/NTSC Horizontal Resolution500 lines Signal-to-Noise Ratio64 dB Video output levelComposite: 1.0 V(p-p)/75 S-video-Y: 1.0 V(p-p)/75 S-video-C: For PAL: 0.3 V(p-p)/75 S-video-C: For NTSC: 0.286 V(p-p)/75 Component-Y: 1.0 V(p-p)/75 Component-PB/PR: 0.
7、7 V(p-p)/75 Video input sensitivity/Impedance (VCR IN)Composite: 1.0 V(p-p)/75 S-video-Y: 1.0 V(p-p)/75 S-video-C: For PAL: 0.3 V(p-p)/75 S-video-C: For NTSC: 0.286 V(p-p)/75 Tuner sectionTuning RangeFM87.5 MHz to 108.0 MHz AM531 kHz to 1 710 kHz (at 9 kHz channel spacing) 530 kHz to 1 710 kHz (at 1
8、0 kHz channel spacing) For Middle East531 kHz to 1 602 kHz (at 9 kHz channel spacing) 530 kHz to 1 600 kHz (at 10 kHz channel spacing) GeneralPower RequirementsAC 110-240 V , 50/60 Hz Power Consumption19 W (at operation) 1.9 W (in standby mode) Dimensions (W H D)400 mm 85 mm 399 mm Mass4.2 kg (9.3 l
9、bs) Amplifier sectionFront140W per channel, RMS at 4 at 1 kHz, with 10 % total harmonic distortion. Center/Surround130W per channel, RMS at 4 at 1 kHz, with 10 % total harmonic distortion. Subwoofer140 W, RMS at 4 at 100 Hz, with 10 % total harmonic distortion. Speaker sectionSpeaker unit16 cm Bass-
10、reflex Power Handling Capacity140 W Impedance4 Frequency Range30 Hz to 200 Hz GeneralPower RequirementsAC 110 V/ AC 127 V/AC 220-240 V , 50/60 Hz Power Consumption135 W (at operation) 0 W (in standby mode) Dimensions (W H D)169 mm 411 mm 451 mm Mass11.3 kg RadioFans.CN 收音机爱 好者资料库 (No.MB420)1-3 Satel
11、lite Speakers (SP-XTHC3) Designs & specifications are subject to change without notice. Front speakers (SP-THC3F)Speaker unit8.0 cm 1.5 cm Bass-reflex, Magnetically Shielded Power Handling Capacity140 W Impedance4 Frequency Range80 Hz to 20 kHz Dimensions (W H D)104.5 mm 139 mm 101 mm Mass0.56 kg ea
12、ch Center speaker (SP-THC3C)Speaker unit8.0 cm 1.5 cm Bass-reflex, Magnetically Shielded Power Handling Capacity140 W Impedance4 Frequency Range80 Hz to 20 kHz Dimensions (W H D)137 mm 105 mm 104.5 mm Mass0.57 kg (1.3 lbs) Surround speakers (SP-THC3S)Speaker unit8.0 cm Bass-reflex Power Handling Cap
13、acity140 W Impedance4 Frequency Range80 Hz to 20 kHz Dimensions (W H D)111.5 mm 148 mm 106.5 mm Mass0.56 kg each 1-4 (No.MB420) SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For c
14、ontinued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry o
15、f the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electri
16、cal and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Repla
17、cement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does
18、 not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts,
19、 high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock
20、hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do
21、not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known g
22、ood earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capa
23、citor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the
24、 resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC THC3 ddcs sm 维修 电路 原理图