JVC-THC7-ddcs-sm维修电路原理图.pdf
《JVC-THC7-ddcs-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-THC7-ddcs-sm维修电路原理图.pdf(72页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2005 Victor Company of Japan, Limited No.MB415 2005/7 DVD DIGITAL THEATER SYSTEM MB41520057 TH-C7 Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade) TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-30 5TROUBLESHOOTING . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35 (XV-THC7) (SP-PWC7) (SP-THC7F) (SP-THC7C) (SP-THC5S) Area suffix J - U.S.A. RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB415) SPECIFICATION Center unit (XV-THC7) *1: This value is measured at System cord CONN
5、ECTOR for reference. *2: Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz) Subwoofer (SP-PWC7) Audio section Total Harmonic Distortion *10.02% Digital input *2DIGITAL IN (DBS) (OPTICAL) - 21 dBm to - 15 dBm (660 nm 30 nm) Video s
6、ection Video SystemNTSC Horizontal Resolution500 lines Signal-to-Noise Ratio64 dB Video output levelComposite1.0 V(p-p)/75 S-video-Y1.0 V(p-p)/75 S-video-C0.286 V(p-p)/75 Component-Y1.0 V(p-p)/75 Component-PB/PR 0.7 V(p-p)/75 Video input sensitivity/ Impedance (VCR IN) Composite1.0 V(p-p)/75 S-video
7、-Y1.0 V(p-p)/75 S-video-C0.286 V(p-p)/75 Tuner section Tuning RangeFM87.5 MHz to 108.0 MHz AM530 kHz to 1 710 kHz GeneralPower RequirementsAC 120 V , 60 Hz Power Consumption16 W (at operation) 1.3 W (in standby mode) Dimensions (W H D)400 mm 85 mm 399 mm(15-3/4 inches 3-3/8 inches 15-3/4 inches) Mas
8、s4.2 kg (9.3 lbs) Amplifier sectionFront/Center/Surround167 W per channel, RMS at 3 at 1kHz, with 10 % total harmonic distortion. Subwoofer167 W, RMS at 3 at 100 Hz, with 10 % total harmonic distortion. Speaker sectionSpeaker unit25 cm (9-7/8 inches) Bass-reflex Power Handling Capacity170 W Impedanc
9、e3 Frequency Range25 Hz to 200 Hz GeneralPower RequirementsAC 120 V , 60 Hz Power Consumption160 W (at operation) 0 W (in standby mode) Dimensions (W H D)264 mm 481 mm 459 mm(10-7/16 inches 18-15/16 inches 18-1/8 inches) Mass16.5 kg (37 lbs) RadioFans.CN 收音机爱 好者资料库 (No.MB415)1-3 Satellite Speakers (
10、SP-XTHC7) Designs & specifications are subject to change without notice. Front speakers (SP-THC7F) Speaker unitWoofer10 cm (3-15/16 inches) 4 Tweeter4 cm (1-5/8 inches) Bass-reflex, Magnetically Shielded Power Handling Capacity 170 W Impedance3 Frequency Range60 Hz to 20 kHz Dimensions (W H D)270 mm
11、 1 085 mm 310 mm(10-11/16 inches 42-3/4 inches 12-1/4 inches) Mass8.8 kg (19.4 lbs) each Center speaker (SP-THC7C) Speaker unitWoofer10 cm (3-15/16 inches) 2 Tweeter4 cm (1-5/8 inches) Bass-reflex, Magnetically Shielded Power Handling Capacity 170 W Impedance3 Frequency Range65 Hz to 20 kHz Dimensio
12、ns (W H D)380 mm 141 mm 163 mm(15 inches 4-9/16 inches 6-7/16 inches) Mass3.4 kg (7.5 lbs) Surround speakers (SP-THC5S) Speaker unit8.0 cm (3-3/16 inches) Bass-reflex Power Handling Capacity 170 W Impedance3 Frequency Range80 Hz to 20 kHz Dimensions (W H D)111.5 mm 148 mm 106.5 mm(4-7/16 inches 5-7/
13、8 inches 4-1/4 inches) Mass0.44 kg (0.97 lbs) each 1-4 (No.MB415) SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original
14、 design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of th
15、e product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-r
16、elated characteristics. These characteris- tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics a
17、re identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended
18、 replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for t
19、he prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform
20、an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug t
21、he AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA
22、AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth g
23、round. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat
24、 each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety