1、SERVICE MANUAL COPYRIGHT 2005 Victor Company of Japan, Limited No.MB448 2005/9 AUDIO/VIDEO CONTROL RECEIVER MB44820059 RX-D402B, RX-D401S Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade) TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 5TROUBLESHOOTING . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 Area suffix J - U.S.A. RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB448) SPECIFICATION *Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz).
5、Designs and specifications are subject to change without notice. AmplifierOutput Power At stereo operationFront channels110 W per channel, min. RMS, driven into 6 at 20 Hz to 20 kHz with no more than 0.8% total harmonic distortion. At surround operationFront channels110 W per channel, min. RMS, driv
6、en into 6 at 1 kHz with no more than 0.8% total har- monic distortion. Center channel110 W, min. RMS, driven into 6 at 1 kHz,with no more than 0.8% total harmonic distortion. Surround channels110 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total har- monic distortion. Sur
7、round back channels110 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total har- monic distortion. AudioAudio Input Sensitivity/ Impedance DVR/DVD, VCR, DBS, TV270 mV/47 k Audio Input (DIGITAL IN)* CoaxialDIGITAL IN 1(DVR/DVD): 0.5 V(p-p)/75 OpticalDIGITAL IN 2(DBS), 3(VCR):
8、 -21 dBm to -15 dBm (660 nm 30 nm) USBUSB Audio Output LevelDVR, VCR270 mV Signal-to-Noise Ratio (66 IHF/78 IHF)80 dB/62 dB Frequency Response (6 )20 Hz to 20 kHz (1 dB) Bass Boost+4 dB 1 dB at 100 Hz Equalization (at DSP operation) Center frequency63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz Control range8
9、dB VideoVideo Input Sensitivity/ Impedance Composite video:DVR/DVD, VCR, DBS1 V(p-p)/75 S-video:DVR/DVD, VCR, DBSY (luminance): 1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:DVR/DVD, VCR (DBS)Y (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 Video Output Level/ Impedance Composite vide
10、o: DVR, VCR, MONITOR OUT 1 V(p-p)/75 S-video: DVR, VCR, MONITOR OUTY (luminance): 1 V(p-p)/75 C (chrominance, burst): 0.286 V(p-p)/75 Component: MONITOR OUTY (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 SynchronizationNegative HDMIHDMI Input (Ver. 1.1)VCR (DBS), DVR/DVD HDMI Output (Ver. 1.0)MONIT
11、OR OUT FM tuner (IHF) Tuning Range87.5 MHz to 108.0 MHz Usable SensitivityMonaural12.8 dBf (1.2 V/75 ) 50 dB Quieting SensitivityMonaural16.0 dBf (1.7 V/75 ) Stereo37.5 dBf (20.5 V/75 ) Stereo Separation at REC OUT35 dB at 1 kHz AM tunerTuning Range530 kHz to 1 710 kHz GeneralPower RequirementsAC 12
12、0 V , 60 Hz Power Consumption150 W/200 VA (at operation) 0.9 W (in standby mode) Dimensions (W H D)435 mm 91.5 mm 371 mm (17 3/16 inch- es 3 5/8 inches 14 5/8 inches) Mass7.1 kg (15.7 lbs) RadioFans.CN 收音机爱 好者资料库 (No.MB448)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this produc
13、t contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Servi
14、ces should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufac
15、ture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor can the protection afforded by them necess
16、arily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics
17、 and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are ro
18、uted and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it s
19、hould be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, con
20、trol shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of t
21、he cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more s
22、ensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particula
23、rly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equ
24、ipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essential that safety critic