JVC-THA35-ddcs-sm维修电路原理图.pdf
《JVC-THA35-ddcs-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-THA35-ddcs-sm维修电路原理图.pdf(64页珍藏版)》请在收音机爱好者资料库上搜索。
1、TH-A35 TH-A35 SERVICE MANUAL DVD DIGITAL CINEMA SYSTEM Contents COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD. No. 22020 Jun. 2003 Safety precautions - 1- 2 Preventing static electricity - 1- 3 Important for laser products - 1- 4 Disassembly method - 1- 5 Description of major ICs - 1- 15 Wiring connec
2、tion - 1- 20 Area Suffix J . U.S.A. C . Canada COMPACT SUPER VIDEO D I G I T A L S U R R O U N D D I G I T A L E X P R O L O G I C VOLUME PHONES DSPSORROUNDSOURCE STANDBY STANDBY/ON RadioFans.CN 收音机爱 好者资料库 TH-A35 1-2 Warning !CAUTION Good earth ground Place this probe on each exposed metal part. AC
3、VOLTMETER (Having 1000 ohms/v 1500 10W olts, or more sensitivity) 0.15 F AC TYPE Safety Precautions 1. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unle
4、ss authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only. 2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product shoul
5、d not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. 3. Many electrical and mechanical parts in the products have special safety-related character
6、istics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the P
7、arts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ! ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown
8、 in the Parts List of Service Manual may create shock, fire, or other hazards. 4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric
9、 shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling. 5. Leakage currnet check (Electrical shock hazard testing) After re-assembling the product, always perform
10、 an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock. Do not use a line isolation transformer during this check. ? Plug t
11、he AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (
12、r.m.s.) ? Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC- type capacitor between an exposed metal part and a known good earth
13、 ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repe
14、at each measurement. Voltage measured Any must not exceed 0.75 V AC(r.m.s.). This corresponds to 0.5 mA AC(r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards. 2. It is the legal responsibility of the repairer to ensure that these safety standards are
15、 maintained. 3. Repairs must be made in accordance with the relevant safety standards. 4. It is essential that safety critical components are replaced by approved parts. 5. If mains voltage selector is provided, check setting for local voltage. Burrs formed during molding may be left over on some pa
16、rts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system. RadioFans.CN 收音机爱 好者资料库 TH-A35 1-3 Preventing static electricity Electrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy
17、 the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs. 1.1. Grounding to prevent damage by static electricity Static electricity in the work area can destroy the optical pickup (laser diode) in devices such as DVD players. Be careful to use proper
18、grounding in the area where repairs are being performed. 1.1.1. Ground the workbench 1. Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the traverse unit (optical pickup) on it. 1.1.2. Ground yourself 1. Use an anti-static wrist
19、 strap to release any static electricity built up in your body. 1.1.3. Handling the optical pickup 1. In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement optical pickup are shorted. After replacement, return the shorted parts to the
20、ir original condition. (Refer to the text.) 2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily destroy the laser diode. 1.2. Handling the traverse unit (optical pickup) 1. Do not subject the traverse unit (optical pick
21、up) to strong shocks, as it is a sensitive, complex unit. 2. Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refer to the replacement procedure in the text. Remove the anti-static pin when replacing the traverse unit. Be ca
22、reful not to take too long a time when attaching it to the connector. 3. Handle the flexible cable carefully as it may break when subjected to strong force. 4. It is not possible to adjust the semi-fixed resistor that adjusts the laser power. Do not turn it. Conductive material (conductive sheet) or
23、 iron plate (caption) Anti-static wrist strap 1M TH-A35 1-4 1. CLASS 1 LASER PRODUCT 2. CAUTION : Visible and invisible laser radiation when open and interlock failed or defeated. Avoid direct exposure to beam. 3. CAUTION : There are no serviceable parts inside the Laser Unit. Do not disassemble the
24、 Laser Unit. Replace the complete Laser Unit if it malfunctions. 4. CAUTION : The compact disc player uses invisible laser radiation and is equipped with safety switches which prevent emission of radiation when the drawer is open and the safety interlocks have failed or are defeated. It is dangerous
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC THA35 ddcs sm 维修 电路 原理图