1、SERVICE MANUAL AUDIO/VIDEO CONTROL RECEIVER No.20938 Apr. 2001 COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD. RX-7010RBK RX-7012RSL RX-7010RBK/RX-7012RSL Contents Safety precautions -1-2 Disassembly method -1-3 Adjustment method -1-8 Description of major ICs -1-9 19 As for RX-7012RSL the body is silve
2、r color EContinental Europe Area Suffix ENNorthern Europe D I G I T A L CONTROL + + + 231 564 897/P 0+1010 BASS BOOSTEFFECT MENU ENTER TEST+ REARL SOUND SUB WOOFER + REARR + MUTING CHTV VOL PLAY STOP /REWFF/ VOLUME CA TV/DBS CONTROL TV/VIDEO REC PAUSE PAUSE RETURNFM MODE100+ CONTROL A/V CONTROL RECE
3、IVER RM-SRX7010R CATV/DBSVCRTVAUDIO DSP MODEINPUTON/OFF DVD MUILTIDVDCD TAPE/CDR TREBLE TV/DBSVCRPHONO FM/AM BASS SURROUNDANALOG/DIGIT ALSLEEP + CENTER TUNING + + PTYPTY+ PTY SEARCH DISPLAY DVDVCRTV SOUND/DBS ADJUST AUDIO/VIDEO CONTROL RECEIVER SETTING MASTER VOLUME CONTROL DOWNUP CDTAPE/CDR SOURCE
4、NAME BASS BOOST INPUT ANALOG/DIGITAL SPEAKERS ON/OFF DSP MODE PHONES SURROUND ON/OFF FM/AM TUNING STANDBY FM/AM PRESETFM MODE MEMORY INPUT ATT FM/AM D I G I T A L D I G I T A L SURROUND DVD MULTI PHONO SOURCE NAME 12 COMPULINK Remote STANDBY/ON EONPTY SEARCHTA/NEWS/INFODISPLAY MODE RadioFans.CN 收音机爱
5、 好者资料库 RX-7010RBK/RX-7012RSL 1-2 1. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts mus
6、t be identical to those used in the original circuits. Services should be performed by qualified personnel only. 2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the ma
7、nufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. 3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual ins
8、pection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such feat
9、ures are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other
10、 hazards. 4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead r
11、outing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling. 5. Leakage currnet check (Electrical shock hazard testing) After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenn
12、a terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock. Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Te
13、ster, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the
14、 AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter
15、. Move the resistor connection to eachexposed metal part, particularly any exposed metal part having a return path to the chassis, and meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. voltage measured Any must not exceed 0.75 V AC (r.m.s
16、.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards. 2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained. 3. Repairs must be made in accordance with the relevant saf
17、ety standards. 4. It is essential that safety critical components are replaced by approved parts. 5. If mains voltage selector is provided, check setting for local voltage. Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500
18、10W 0.15 F AC TYPE ! Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system. In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts
19、 that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (Except the JC version) http:/getMANUAL.com RadioFan
20、s.CN 收音机爱 好者资料库 RX-7010RBK/RX-7012RSL 1-3 Remove the four screws A attaching the top cover on both sides of the body. Remove the three screws B on the back of the body. Remove the top cover from behind in the direction of the arrow while pulling both sides outward. 1. 2. 3. Disassembly method Removi
21、ng the top cover (See Fig.1) Prior to performing the following procedure, remove the top cover. Remove the power cord stopper from the rear panel by moving it in the direction of the arrow. Remove the twenty seven screws E attaching the each boards to the rear panel on the back of the body. Remove t
22、he four screws F attaching the rear panel on the back of the body. 1. 2. 3. Removing the rear panel (See Fig.4) Prior to performing the following procedure, remove the top cover. Disconnect the card wire from connector CN402 on the audio board and CN201 on the power supply board in the front panel a
23、ssembly. Cut off the tie band fixing the harness. Remove the three screws C attaching the front panel assembly. Remove the four screws D attaching the front panel assembly on the bottom of the body. Detach the front panel assembly toward the front. 1. 2. 3. 4. Removing the front panel assembly (See
24、Fig.2 and 3) Fig.1 Fig.2 Fig.3 Fig.4 A 2 A 2 B Top cover C Power supply board Audio board CN402 Main board Tie band D E E FEF F Cord stopper C Front panel assembly Front panel assembly D Rear panel CN201 F EEEE RX-7010RBK/RX-7012RSL 1-4 Prior to performing the following procedure, remove the top cov
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC RX7010RBK avr sm2 维修 电路 原理图