JVC-RX6040B-avr-sm维修电路原理图.pdf
《JVC-RX6040B-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RX6040B-avr-sm维修电路原理图.pdf(63页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2004 VICTOR COMPANY OF JAPAN, LIMITED No.MB159 2004/2 AUDIO/VIDEO CONTROL RECEIVER MB15920042 RX-6040B TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . 1-6 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . 1-15 Area suffix J - U.S.A. C - Canada TA/NEWS/INFO DISPLAY MODE RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB159) SPECIFICATION Designs and specifications are subject to change without notice. Amplifier Output Power At Stereo operationFront channels100 W per channel, min. RMS, driven into 8 , 40
5、 Hz to 20 kHz with no more than 0.8% total harmonic distortion. At Surround operationFront channels100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion. Center channel100 W, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic dis
6、tortion. Surround channels 100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion. Audio Audio Input Sensitivity/Impedance (1 kHz) CD, TAPE/CDR, VCR, TV SOUND, DVD:220 mV/47 k Audio Input (DIGITAL IN)*CoaxialDIGITAL 1 (DVD):0.5 V(p-p)/75 OpticalDIGITAL
7、 2 (CD), DIGITAL 3 (TV):-21 dBm to -15 dBm (660 nm 30 nm) * Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency-32 kHz, 44.1 kHz, 48 kHz) Recording Output LevelTAPE/CDR, VCR:220 mV Signal-to-Noise Ratio (66 IHF/78 IHF)CD, TAPE/CDR, VCR, TV SOUND, DVD:87 dB/7
8、4 dB Frequency Response (8 )CD, TAPE/CDR, VCR, TV SOUND, DVD:20 Hz to 50 kHz (+1 dB, -3 dB) Bass Boost+3 dB 1 dB at 100 Hz Equalization (5 bands) 63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz:8 dB (in 2 dB steps) Video Video Input Sensitivity/ImpedanceComposite video:DVD, VCR1 V(p-p)/75 S-video:DVD, VCR(Y: lu
9、minance):1 V(p-p)/75 (C: chrominance, burst):0.286 V(p-p)/75 ComponentDVD, VCR(Y: luminance):1 V(p-p)/75 (PB, PR):0.7 V(p-p)/75 Video Output LevelComposite video:VCR, MONITOR OUT 1 V(p-p)/75 S-video:VCR, MONITOR OUT(Y: luminance):1 V(p-p)/75 :0.286 V(p-p)/75 (C: chrominance, burst) ComponentMONITOR
10、OUT(Y: luminance):1 V(p-p)/75 (PB, PR)0.7 V(p-p)/75 SynchronizationNegative Signal-to-Noise Ratio45 dB FM tuner (IHF) Tuning Range87.5 MHz to 108.0 MHz Usable SensitivityMonaural:12.8 dBf (1.2 -V/75 ) 50 dB Quieting SensitivityMonaural:16.0 dBf (1.7 -V/75 ) Stereo:37.5 dBf (20.5 -V/75 ) Stereo Separ
11、ation at OUT (REC)35 dB at 1 kHz AM tuner Tuning Range530 kHz to 1 710 kHz General Power RequirementsAC 120V , 60 Hz Power Consumption180 W/230 VA (at operation), 2 W (in standby mode) Dimensions (W H D)435 mm 146.5 mm 409.5 mm (17 3/16 in. 5 13/16 in. 16 1/8 in.) Mass8.8 kg (19.5 lbs) RadioFans.CN
12、收音机爱 好者资料库 (No.MB159)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the
13、 manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alte
14、rations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics
15、 are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual.
16、Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service M
17、anual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When s
18、ervice is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassembling. (5) Leakage shock hazard testing After reassembling the product, always perform an isolation check on the exposed metal parts of the prod
19、uct (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage
20、Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directl
21、y into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltm
22、eter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (
23、r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance wi
24、th the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay atten