JVC-RXF31S-hccc-sm维修电路原理图.pdf
《JVC-RXF31S-hccc-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RXF31S-hccc-sm维修电路原理图.pdf(65页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2005 Victor Company of Japan, Limited No.MB449 2005/7 HOME CINEMA CONTROL CENTER MB44920057 RX-F31S Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade) TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15 5TROUBLESHOOTING . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15 Area suffix A - Australia US - Singapore UF - China UJ - U.S.Military RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB449) SPECIFICATION *1: Measured on AC 110 V, 127 V, 220 V, and 240 V. *2: Corresponding to
5、Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz). Designs and specifications are subject to change without notice. AmplifierOutput Power At stereo operationFront channels100 W*1 per channel, min. RMS, driven into 6 at 1 kHz with no more than 10% total har- monic
6、 distortion. At surround operationFront channels100 W*1 per channel, min. RMS, driven into 6 at 1 kHz with no more than 0.8% total harmonic distortion. Center channel100 W*1, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distor- tion. Surround channels100 W*1 per channel, m
7、in. RMS, driven into 6 at 1 kHz with no more than 0.8% total harmonic distortion. Surround back channel100 W*1, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distor- tion. AudioAudio Input Sensitivity /Impedance DVR/DVD (DVD MULTI), VCR, DBS, TV330 mV/47 k Audio Input (DIGI
8、TAL IN)*2 Coaxial: DIGITAL IN 1(DVR/DVD)0.5 V(p-p)/75 Optical: DIGITAL IN 2(DBS), 3(VCR)-21 dBm to -15 dBm (660 nm 30 nm) Audio Output LevelDVR, VCR, MONITOR OUT330 mV Signal-to-Noise Ratio (66 IHF/DIN)80 dB/62 dB Frequency Response (8 )20 Hz to 20 kHz (1 dB) Bass Boost+4 dB 1 dB at 100 Hz Equalizat
9、ion (at DSP operation) Center frequency63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz Control range8 dB VideoVideo Input Sensitivity/ Impedance Composite video: DVR/DVD, VCR, DBS1 V(p-p)/75 S-video: DVR/DVD, VCR, DBSY (luminance): 1 V(p-p)/75 C (chrominance, burst): 0.286 V(p-p)/75 Component: DVR/DVD, VCRY (lu
10、minance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 Video Output Level/ Impedance Composite video: DVR, VCR, MONITOR OUT 1 V(p-p)/75 S-video: DVR, VCR, MONITOR OUTY (luminance): 1 V(p-p)/75 C (chrominance, burst): 0.286 V(p-p)/75 Component: MONITOR OUTY (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 Synchro
11、nizationNegative FM tuner (IHF) Tuning Range87.50 MHz to 108.00 MHz Usable SensitivityMonaural12.8 dBf (1.2 V/75 ) 50 dB Quieting SensitivityMonaural16.0 dBf (1.7 V/75 ) Stereo37.5 dBf (20.5 V/75 ) Stereo Separation at OUT(REC)35 dB at 1 kHz AM tunerTuning Range531 kHz to 1 710 kHz (at 9 kHz interva
12、ls) 530 kHz to 1 710 kHz (at 10 kHz intervals) GeneralPower RequirementsAC 110 V/127 V/220 V/230 V - 240 V , adjust- able with the voltage selector, 50 Hz/60 Hz Power Consumption120 W (at operation) 5 W (in standby mode) Dimensions (W H D)435 mm 70 mm 317.2 mm Mass6.3 kg RadioFans.CN 收音机爱 好者资料库 (No.
13、MB449)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer
14、. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or
15、additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are ofte
16、n not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Ele
17、ctrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Ma
18、nual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When se
19、rvice is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the p
20、roduct (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Lea
21、kage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cor
22、d directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the resistor with t
23、he AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed
24、0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in ac