JVC-RXDP10RSL-avr-sm维修电路原理图.pdf
《JVC-RXDP10RSL-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RXDP10RSL-avr-sm维修电路原理图.pdf(132页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL AUDIO/VIDEO CONTROL RECEIVER No.21025 Sep. 2001 COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD. RX-DP10VBK RX-DP10VSL RX-DP10RSL RX-DP10VBK/RX-DP10VSL RX-DP10RSL Contents Safety precautions -1-2 Importance administering point on the safety - 1-4 Disassembly method -1-5 Adjustment method
2、-1-14 Description of major ICs -1-1637 STANDBY/ON STANDBY PHONES AUDIO/VIDEO CONTROL RECEIVER DIMMER CC CONVERTER MAIN ROOM ON/OFF SUB ROOM ON/OFF DOOR UP DOOR DOWN MASTER VOLUME RX-DP10V D I G I T A L D I G I T A L SURROUND S-VIDEOVIDEOLAUDIOR VIDEO CHANNEL TV/VIDEO MUTING DVD ON/OFFON/OFF STANDBY/
3、ONSTANDBY/ON STANDBY TV/CATV/DBSVCR 1 ON DVD MULTICD CDR PHONO TAPE/MD AM ANALOG/DIGITALEFFECT ROOM SIZE SOUND TEST LINE DIRECTCC CONVERTER SLEEPDIMMER FM MODE DSPTHXSURROUND RETURN100+ ON/OFFON/OFFMODE WALL INPUT LIVENESS SET SETUP MENU ADJUST MENU DVD MENU EXIT TEXT DISPLAY 123 456 7/P89 10 +10 0
4、TV VOL VOLUME TUNING STOPPAUSE LIGHT FF/ / REW REC PLAY DOWNUP RM-SRXDP10J REMOTE CONTROL A/V CONTROL RECEIVER VCR 1VCR 2 FMVIDEOTV/DBS SUB ROOM TRANSMITLEARN MAIN ROOM SUB ROOMMAIN ROOM SUB ROOMLEARNMAIN ROOM TV CATV/ DBS Area suffix B - U.K. E - Continental Europe EN - Northern Europe Area suffix
5、J - U.S.A. RX-DP10VSL Area suffix C - Canada RX-DP10VBK RX-DP10RSL ModelRF remote unitVideo SEP boardColor RX-DP10VSL RX-DP10VBKBlack Silver SilverRX-DP10RSL RadioFans.CN 收音机爱 好者资料库 RX-DP10VBK/RX-DP10VSL RX-DP10RSL 1-2 1. This design of this product contains special hardware and many circuits and co
6、mponents specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only. 2
7、. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property da
8、mage resulting therefrom. 3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for
9、higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a
10、substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. 4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to
11、 be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-a
12、ssembling. 5. Leakage current check (Electrical shock hazard testing) After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is sa
13、fe to operate without danger of electrical shock. Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal par
14、t having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a
15、 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return pat
16、h to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet internat
17、ional safety standards. 2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained. 3. Repairs must be made in accordance with the relevant safety standards. 4. It is essential that safety critical components are replaced by approved parts. 5. If mains vol
18、tage selector is provided, check setting for local voltage. Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.15 F AC TYPE ! Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay at
19、tention to such burrs in the case of preforming repair of this system. In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearb
20、y are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (Except the J furthermore the manufacturer cannot accept responsibility for personal injury or property damage resulting therefrom. 3. Essential safety critical comp
21、onents are identified by ( ) on the Parts List and by shading on the schematics, and must never be replaced by parts other than those listed in the manual. Please note however that many electrical and mechanical parts in the product have special safety related characteristics. These characteristics
22、are often not evident from visual inspection. Parts other than specified by the manufacturer may not have the same safety characteristics as the recommended replacement parts shown in the Parts List of the Service Manual and may create shock, fire, or other hazards. 4. The leads in the products are
23、routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it
24、 should be confirmed that they have been returned to normal, after re-assembling. ! Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system. (U.K only) RX-DP10VBK/RX-DP10VSL RX-DP10RSL 1-4 Cauti