JVC-RXF10S-htr-sm维修电路原理图.pdf
《JVC-RXF10S-htr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RXF10S-htr-sm维修电路原理图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2004 Victor Company of Japan, Limited No.MB264 2004/6 HOME THEATER RECEIVER MB26420046 RX-F10S TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 2
2、SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
3、4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . 1-19 Area suffix J - U.S.A. C - Canada RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB264) SPECIFICATION *1: Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz). Designs & specifications are subject to change without notice. Amplifier Output PowerAt stere
5、o op- eration Front channels100 W per channel, min. RMS, both channels driven into 6 at 40 Hz to 20 kHz with no more than 0.8% total harmonic distortion. At surround operation Front channels100 W per channel, min. RMS, driven into 6 at 1 kHz with no more than 0.8% total harmonic distortion. Center c
6、hannel100 W, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion. Surround channels100 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total harmonic distortion. Surround back channel100 W, min. RMS, driven into 6 at 1 kHz, with no more than 0.8
7、% total harmonic distortion. Audio Audio Input Sensitivity/Imped- ance DVR/DVD (DVD MULTI), VCR, DBS, TV:330 mV/47 k Audio Input (DIG- ITAL IN)*1 CoaxialDIGITAL IN 1(DVR/DVD):0.5 V(p-p)/75 OpticalDIGITAL IN 2(DBS), 3(VCR): -21 dBm to -15 dBm (660 nm 30 nm) Audio Output LevelDVR, VCR, MONITOR OUT:330
8、 mV Signal-to-Noise Ratio (66 IHF/ DIN) 80 dB/62 dB Frequency Response (6 )20 Hz to 20 kHz (1 dB) Bass Boost+4 dB 1 dB at 100 Hz Equalization (at DSP operation)Center frequency:63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz Control range:8 dB Video Video Input Sensitivity/Imped- ance Composite video:DVR/DVD, V
9、CR, DBS1 V(p-p)/75 S-video:DVR/DVD, VCR, DBSY (luminance):1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:DVR/DVD, VCRY (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 Video Output Level/ImpedanceComposite video:DVR, VCR, MONITOR OUT 1 V(p-p)/75 S-video:DVR, VCR, MONITOR OUTY (luminance):1
10、 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:MONITOR OUTY (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 SynchronizationNegative FM tuner (IHF) Tuning Range87.5 MHz to 108.0 MHz Usable SensitivityMonaura:12.8 dBf (1.2 V/75 ) 50 dB Quieting SensitivityMonaural:16.0 dBf (1.7 V/75 ) Stereo
11、:37.5 dBf (20.5 V/75 ) Stereo Separation at REC OUT35 dB at 1 kHz AM tuner Tuning Range530 kHz to 1 710 kHz General Power RequirementsAC 120 V , 60 Hz Power Consumption120 W/160 VA (at operation) 2 W (in standby mode) Dimensions (W H D)435 mm 70 mm 329.5 mm (17 3/16 inches 2 13/16 inches 13 inches)
12、Mass6.3 kg (13.9 lbs) RadioFans.CN 收音机爱 好者资料库 (No.MB264)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original desig
13、n unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the prod
14、uct should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related
15、 characteristics. These characteris- tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are ide
16、ntified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended repla
17、cement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the pre
18、vention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an iso
19、la- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC
20、line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.
21、m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground.
22、 Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each
23、measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standa
24、rds are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be