JVC-RX6042S-avr-sm1维修电路原理图.pdf
《JVC-RX6042S-avr-sm1维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RX6042S-avr-sm1维修电路原理图.pdf(48页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2004 Victor Company of Japan, Limited No.MB267 2004/6 AUDIO/VIDEO CONTROL RECEIVER MB26720046 RX-6042S TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . 1-5 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . 1-14 TA/NEWS/INFO DISPLAY MODE Area suffix A - Ausitralia RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB267) SPECIFICATION *1: Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency-32 kHz, 44.1 kHz, 48 kHz) Designs and specifications are subject to change wi
5、thout notice. Amplifier Output Power At Stereo operationFront channels100 W per channel, min. RMS, driven into 8 , 40 Hz to 20 kHz with no more than 0.8% total harmonic distortion. At Surround operationFront channels100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total h
6、armonic distortion. Center channel100 W, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion. Surround chan- nels 100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than 0.8% total harmonic distortion. Audio Audio Input Sensitivity/Impedance (1 kHz) CD
7、, TAPE/CDR, VCR, TV SOUND, DVD:220 mV/47 k Audio Input (DIGITAL IN)*1CoaxialDIGITAL 1 (DVD) OpticalDIGITAL 2 (CD), DIGITAL 3 (TV):-21 dBm to -15 dBm (660 nm 30 nm) Recording Output LevelTAPE/CDR, VCR:220 mV Signal-to-Noise Ratio (66 IHF/78 IHF) CD, TAPE/CDR, VCR, TV SOUND, DVD:87 dB/62 dB Frequency
8、Response (8 )CD, TAPE/CDR, VCR, TV SOUND, DVD:20 Hz to 50 kHz (+1 dB, -3 dB) Bass Boost+3 dB 1 dB at 100 Hz Equalization (5 bands) 63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz:8 dB (in 2 dB steps) Video Video Input Sensitivity/ImpedanceComposite video:DVD, VCR1 V(p-p)/75 S-video:DVD, VCR(Y: luminance):1 V(p-
9、p)/75 (C: chrominance, burst):0.286 V(p-p)/75 ComponentDVD, VCR(Y: luminance):1 V(p-p)/75 (PB, PR):0.7 V(p-p)/75 Video Output LevelComposite video:VCR, MONITOR OUT 1 V(p-p)/75 S-video:VCR, MONITOR OUT(Y: luminance):1 V(p-p)/75 :0.286 V(p-p)/75 (C: chrominance, burst) ComponentMONITOR OUT(Y: luminanc
10、e):1 V(p-p)/75 (PB, PR)0.7 V(p-p)/75 SynchronizationNegative Signal-to-Noise Ratio45 dB RadioFans.CN 收音机爱 好者资料库 (No.MB267)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purposes. For conti
11、nued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only. (2) Alterations of the design or circuitry of the
12、product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical an
13、d mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts
14、 which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the
15、same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperatur
16、e parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassembling. (5) Leakage shock hazard testing Aft
17、er reassembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolati
18、on transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any le
19、akage current must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an exposed m
20、etal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse th
21、e plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the rep
22、airer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Ca
23、ution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagr
24、ams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J